| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAdmitted-Finance 3RD FLOOR KAY M PLAZA GANESHGURI G S ROAD GUWAHATI 06 | GUWAHATI | ASSAM | ₹4.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.4 Cr+₹1.7 L (0.38%)Admitted-Finance 4C PEACE ENCLAVE G S ROAD ULUBARI GUWAHATI ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | ₹4.4 Cr+₹1.7 L (0.38%) | L2 | Admitted-Finance |
| 3 | L3₹4.4 Cr+₹5.2 L (1.19%)Admitted-Finance | ₹4.4 Cr+₹5.2 L (1.19%) | L3 | Admitted-Finance |
| 4 | L4₹4.8 Cr+₹48.5 L (11.2%)Admitted-Finance | ₹4.8 Cr+₹48.5 L (11.2%) | L4 | Admitted-Finance |
| 5 | L5₹4.9 Cr+₹60.4 L (13.9%)Admitted-Finance | ₹4.9 Cr+₹60.4 L (13.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bajaj Electricals Ltd L6 | NORTH EASTERN ENGINEERS L4 | INDUSTRIAL SYSTEMS LLP L1 | M/S POWER GRID ASSOCIATES L5 | M/S Nityananda Borah L3 | Fortune Infratrade Pvt. Ltd. L2 | N.K. ENGINEERING WORKS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 10.00Part -A (Supply of electrical item) | ||||||||||
| 10.01 | "Supply of 3.5CX50 sq mm LV Power Cable ""Supply of 1.1 kV Grade, 3.5C X 50 sq mm LV Power CableAl conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the data sheet of cables" | 2,000 | M | 308 ₹6,16,000 | 261 ₹5,22,000 | 223 ₹4,46,000 Lowest | 372 ₹7,44,000 | 293 ₹5,86,000 | 225 ₹4,50,000 | 369.85 ₹7,39,700 |
| 10.02 | "Supply of 3.5CX95 sq mm LV Power Cable ""Supply of 1.1 kV Grade, 3.5C X 95 sq mm LV Power CableAl conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the data sheet of cables" | 2,000 | M | 528 ₹10,56,000 | 450 ₹9,00,000 | 378 ₹7,56,000 Lowest | 630 ₹12,60,000 | 493 ₹9,86,000 | 381 ₹7,62,000 | 618.38 ₹12,36,760 |
| 10.03 | Supply of 3Cx2.5 sq mm Control Cable""Supply of 1.1 kV Grade, 3C x 2.5 sq mm Control CableCU conductor, XLPE insulated, Extruded PVC inner sheathed,armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables | 3,000 | M | 141 ₹4,23,000 | 117 ₹3,51,000 | 100 ₹3,00,000 Lowest | 162 ₹4,86,000 | 131 ₹3,93,000 | 101 ₹3,03,000 | 152.66 ₹4,57,980 |
| 10.04 | Supply of 1.1 kV Grade, 4C x 10 sq mm LV Power CableCU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables | 8,000 | M | 524 ₹41,92,000 | 405 ₹32,40,000 | 380 ₹30,40,000 Lowest | 623 ₹49,84,000 | 473 ₹37,84,000 | 383 ₹30,64,000 | 592.79 ₹47,42,320 |
| 10.05 | Supply of of class B, GI pipes/ sleeves,Supply of of class B,
GI pipes/ sleeves, 50 mm dia" | 50 | M | 1,196 ₹59,800 | 1,170 ₹58,500 | 545 ₹27,250 | 275 ₹13,750 Lowest | 536 ₹26,800 | 549 ₹27,450 | 620.2 ₹31,010 |
| 10.06 | Supply of Earth strip GI 25 X 6 mm | 300 | M | 154 ₹46,200 | 180 ₹54,000 | 124 ₹37,200 | 167 ₹50,100 | 119 ₹35,700 Lowest | 125 ₹37,500 | 155 ₹46,500 |
| 10.07 | Supply of 10 SWG GI Wire | 100 | M | 26 ₹2,600 | 12 ₹1,200 Lowest | 87 ₹8,700 | 15 ₹1,500 | 24 ₹2,400 | 88 ₹8,800 | 36 ₹3,600 |
| 10.08 | Supply of 5/6 A, one way modular switch, ISI marked, Make - Havells/Anchor/Legrand/L&T or equivalent and as per the direction of EIC. | 50 | NOS | 60 ₹3,000 | 200 ₹10,000 | 36 ₹1,800 | 28 ₹1,400 | 21 ₹1,050 Lowest | 37 ₹1,850 | 55.1 ₹2,755 |
| 10.09 | Supply of 3 pin 5/6 A modular socket outlet, ISI marked ,Make -Havells/Anchor/Legrand/L&T or equivalent and as per the direction of EIC. | 50 | NOS | 175 ₹8,750 | 250 ₹12,500 | 94 ₹4,700 | 85 ₹4,250 | 72 ₹3,600 Lowest | 95 ₹4,750 | 112.55 ₹5,627.5 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
17 Nov 2022, 11:00 amClosed
Kaveri Hazarika 9435703123
Numaligarh Refinery Limited
Lighting facilities for NREP Project area at Rajabari etc. at NRL Site
2022_NRL_719675_1
OC10000490/KAV
Open Tender
Miscellaneous Works
Works
210 days
Numaligarh Refinery Limited
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1 L
Yes
22 Dec 2022
22 Oct 2022
18 Nov 2022
22 Oct 2022
17 Nov 2022
28 Oct 2022
Amount
Part -A (Supply of electrical item)
"Supply of 3.5CX50 sq mm LV Power Cable ""Supply of 1.1 kV Grade, 3.5C X 50 sq mm LV Power CableAl conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the data sheet of cables"
"Supply of 3.5CX95 sq mm LV Power Cable ""Supply of 1.1 kV Grade, 3.5C X 95 sq mm LV Power CableAl conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the data sheet of cables"
Supply of 3Cx2.5 sq mm Control Cable""Supply of 1.1 kV Grade, 3C x 2.5 sq mm Control CableCU conductor, XLPE insulated, Extruded PVC inner sheathed,armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables
Supply of 1.1 kV Grade, 4C x 10 sq mm LV Power CableCU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables
Supply of of class B, GI pipes/ sleeves,Supply of of class B, GI pipes/ sleeves, 50 mm dia"
Supply of Earth strip GI 25 X 6 mm
Supply of 10 SWG GI Wire
Supply of 5/6 A, one way modular switch, ISI marked, Make - Havells/Anchor/Legrand/L&T or equivalent and as per the direction of EIC.
Supply of 3 pin 5/6 A modular socket outlet, ISI marked ,Make -Havells/Anchor/Legrand/L&T or equivalent and as per the direction of EIC.
Supply of 15/16 A, one way modular switch, ISI marked, Make - Havells/Anchor/Legrand or equivalent and as per the direction of EIC.
Supply of 6 pin 15/16 A modular socket outlet, ISI marked, White, Make - Havells/Anchor/Legrand or equivalent and as per the direction of EIC.
Supply of modular base & cover plate for 3 module, White, Make - Havells/Anchor/Legrand/MARU or equivalent and as per the direction of EIC.
Supply of Modular GI box for 3 module, Make - Havells/Anchor/Legrand/MARU or equivalent and as per the direction of EIC.
Supply of heatshrinkable Straight Through cable jointing kit for 3.5- Core LT cables ( 1.1KV ) of size: 25 to 50 Sq.mm, Make:UCIL / Compaq Int./ Rychem RPG or equivalent , Equvalent to EPKJ0130 of RAYCHEM complete as per the direction of E-I-C.
Supply of heat shrinkable Straight Through cable jointing kit for 3/3.5/4 Core LT cables ( 1.1KV ) of size: 70 to 150 Sq.mm, Make: Raychem RPG/3M or equivalent, and as per the direction of E-I-C.
Supply of heat shrinkable Straight Through cable jointing kit for 3/3.5 core LT cables ( 1.1KV ) of size: 185 to 300 Sq.mm, Make: Raychem RPG/3M or equivalent, and as per the direction of E-I-C.
Supply of 18W,6000K decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient equivalent to HAVELLS Ordering code LHEXBTP7UN1W018, Make : Havells/Bajaj/Philips/Jaguar or equivalent as per the direction of EIC
Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable, Make : Finolex, Rallison,Havells or equivalent and as per the direction of E.I.C.
Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable, Make : Finolex, Rallison,Havells or equivalent and as per the direction of E.I.C.
Supply of 4 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable, Make : Finolex, Rallison,Havells or equivalent and as per the direction of E.I.C.
Supply of 6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C.
Supply of 6 A to 32 A ratings, DP MCB, “C” curve, 10 kA breaking capacity, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C.
Supply of 40 A rating, 2 pole RCCB, 300mA, Make : Legrand/Schneider/L&T/ABB or equivalent and as per the direction of E-I-C.
Supply of 63 A rating, 4 pole RCCB, 30mA, Make : Legrand/L&T/Schneider or equivalent and as per the direction of E-I-C.
Supply of 12 way, 12 modules, IP43 Double Door SPN distribution boards with acrylic door Make: Hager/Legrand/Havells/Schneider/Anchor or equivalent and as per the direction of E-I-C.
Supply of 8 way, 8+24 modules, IP43 Double Door TPN distribution boards with acrylic door, Make: Hager/Legrand/Havells/Schneider/Anchor or equivalent and as per the direction of E-I-C.
Supply of Weather Proof Cable Gland for 1.1kV Grade Cable Double compression Nickel plated brass cable gland suitable for cable upto 300 sqmm
Supply of transformer oil having the following specification: Transformer Oil for Power Transformer-IS-335/1993 (4th rev)-the Oil should have Density at 29.5 degC = 0.89 g/cm3 (max), Viscosity at 27 degC = 2 7 cSt (max), Min Break down Volt for unfiltered oil = 30 kV, Specific resistance at 27 degC = 1500 x 10sqr12 Ohm-cm (min), Water content = 50 ppm (max).
Supply of 500kVA Outdoor type 11/0.433 KV copper wound distribution transformer bushing at HT side and Cable entry at LT side as per technical specification attached with the tender
Supply of 4P MCB 63A “C” curve, 10 kA breaking capacity,Utilisation category A, Make Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C.
Supply of 3P MCB 63A “C” curve, 10 kA breaking capacity,Utilisation category A, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C.
Supply of 3P MCB 32A “C” curve, 10 kA breaking capacity,Utilisation category A, Make : Legrand/Havells/Schneider or equivalent and as per the direction of E-I-C.
Supply of 2P RCCB 25A ,300mA, Make : Legrand/Schneider/L&T/ABB or equivalent and as per the direction of E-I-C.
Supplying of sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve 4P MCB complete with connections, testing and commissioning etc. as required.
Supply of lugs of following sizes: 1. 2.5 sq. mm Cu Ring Type insulated. 2. 2.5 sq.mm Cu Pin type insulated. 3. 4 sq. mm Cu Ring Type. 4. 4 sq. mm Cu Pin Terminal Type. 5. 10 sq.mm Cu Ring Type 6. 10 sq.mm Cu Pin Terminal Type 7. 16 sq.mm Cu Ring Type 8. 25 sq.mm Cu Ring Type Make: Dowells/Jainsons or equivalent and as per direction of E-i-C.
Supply of 1.1 kV Grade, 4C x 6 sq mm LV Power Cable CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables
Providing and fixing following rating and breaking capacity and pole MCCB with microprocessor based release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A, 36KA, FPMCCB suitable for mounting in VTPN DB. Make: L&T, Schneider or equivalent
Part-B - (Composite service)
Supply, Installation, earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire , testing and commissioning of lighting luminaires and other accessories suitable for outdoor installation. This shall include transportation from owner's issue point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any modifications required for proper commissioning of fixture. Following Site Conditions will be considered for design and installation of 30 meter heigh High Mast : ● Maximum Ambient temperature : 38 Deg C ● Minimum Ambient temperature : 5 Deg C ● Equipment design temperature : 40 Deg C ● Earthquake Design factor : (Code IS-1893 Zone-V/Site spectra whichever is governing), As per IS 1893,Seismic factor = 0.36 ● Wind speed : 50 meter / sec ● Site Altitude : 90 m above MSL ● Relative humidity : 85% at 3 Deg C ● Environmental conditions : Corrosive Industrial Environment / Extreme Moisture (Tropical Climate) The High Mast shall be comply the flowing codes and standards as minimum, but not limited to the following : ●PLG 7 High Masts for Lighting and CCTV ●SANS 10225:2012 High Mast natural frequency calculation ●IS 875 Part – 3 Wind Loading ●IS 2062/ BS EN 10025 High Tensile Steel Sheets ●IS 2062 Mild Steel ●BS EN ISO 1461 Galvanization ●IS 3459 / 2266 Stainless steel Wire rope ●IS 9968 Part – 1 Trailing Cable ●IS 12615 Motor ●IP66, IK08, wind tunnel test on a specimen to establish the force coefficients of the 20-side polygon and the value received from the wind tunnel test is to be taken in design, The winches are to be type tested through reputed institutions like IIT as consultants. 30 Meter High Mast with 12x400W LED Lighting fixtures comprising of the following as a minimum : ● 30 Meter High Mast shaft in three sections suitable for required wind speed with raising / lowering system comprising of frame for luminaries carriage suitable to install 12 nos luminaries in symmetrical arrangement, SS Wire rope, trailing cable, motor, manual handle, junction box, lightning protections including lighting finile and all other accessories required for the complete installation of the High Mast. ● MS anchor Foundation bolts as per Civil drawing along with nuts, washers, anchor plates and templates ● Non-integral flood light luminaries of 400W LED Fixtures with control gear boxes ● Two nos. aviation obstruction lights with 9W LED Lamps ● Outdoor stand mounted flameproof MCB DB/ flameproof Feeder pillar distribution box with Incomer / outgoing MCB, ELCB, timers suitable for Zone 2 gas group IIA/IIB, Temp. Class T3. ● Trailing cables, wires as required (except the incoming power cables to Feeder Pillar Box / MCB Distribution Box). ● Supply shall include commissioning spares as required (List shall be provided by bidder)
SITC of Solar Mini Mast of height 12M with 5x40 W All-in-one LED Light as per technical specification attached in the tender document
Supply & installation hot dip galvanised tubular GI Flood Lighting Poles of requisite standards of length 11 meters , including supply and installation of cable glands, lugs, terminals, riser GI pipes, wire rope earthing, cleats, internal armoured copper cabling from marshalling box to fixture, etc.; Installation, testing and commissioning of light fixtures and luminaires, glanding, termination etc. complete, as may be required including necessary excavation, RCC foundation work, backfilling, supply of cement, labour, all materials, removal of excess earth etc; but excluding supply of light fixtures, luminaires.
1x120W LED Based Street Lighting Fixture Supply, Installation, testing & commissioning of 1x120W LED Based Street Lighting Fixtures for Street Lighting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of minimum IK07. System Lumen Efficacy ≥110Lm/W, High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W. High efficiency polycarbonate UV stablized cover , Powered by integral, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Over Voltage protection, Surge Voltage protection 10KV with SPD & other safety test as per IS 15885 Part-2/Sec 13. Make: Havells/Jaguar/Philips/CG or equivalent and as per direction of E-i-C.
SITC of Solar Street Light Solar LED Street Light :Solar LED Street Light : Supply, installation, testing and commissioning of All In One Solar Street Light street lighting of wattage - 60W LED, complete with all necessary accessories suitable for 2 days autonomy including solar PV panel Monocrystalline type 90 Wp +/_ 10%, Lithium Ferro Phosphate Battery 12.8V 42 Ah , Efficiency >90%, System Lumen Efficacy 150 Lumen/W , MPPT charge controller 12V , 7A ,LED Make OSRAM/Cree/ Equivalent with Life span of 50000 Hours , Inbuilt DC Type Driver, Aluminium Extruded Body with OEM Logo, , battery casing with IP 65 protection, Dusk to Dawn Operation provided along with intelligent dimming profile, with necessary protections like i. Over charged Protection , ii. Deep Discharge protection , iii. Over current protection iii. Short Circuit Protection ,v. Overvoltage Projection as required mounting brackets, , etc. with LED display to indicate the charging status of battery , , automatic ON-OFF system and other accessories and systems complete, brackets and supports, mounting clamps, necessary cabling, wiring and conduiting etc. as may be required. Make - Bajaj, CG, Philips, HAVELLS, GE, equivalent as approved by E-I-C. Supply, Erection, Testing and commissioning of 9 Meter Height Hot dip Galvanised Octagonal Street Lighting Pole of Single ARM including four nos foundation Anchor bolts and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity.Supply, Installation, earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire , testing and commissioning of lighting luminaires (including junction box) and other accessories suitable for outdoor installation. This shall include transportation from owner's issue point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge. Following Site Conditions will be considered for design and installation of 9 meter height Single ARM Tubular Street Lighting Pole:# Maximum Ambient temperature : 38 Deg C# Minimum Ambient temperature : 5 Deg C# Equipment design temperature : 40 Deg C#Earthquake Design factor:(Code IS-1893 Zone-V/Site spectra whichever is governing), As per IS 1893,Seismic factor = 0.36# Wind speed : 50 meter / sec# Site Altitude : 90 m above MSL# Relative humidity : 85% at 3 Deg C#Environmental conditions : Corrosive Industrial Environment / Extreme Moisture (Tropical Climate)The Lighting Pole will comply the following specification as minimum, but not limited to the following :# Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity.# The pole shaft shall be made from sheet steel .# The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ( Item is inclusive of excavation and backfilling, RCC work, accessories etc. complete with all associated works).
Supply, Installation, connection of 40 mm dia & 3000 mm long GI ROD electrode. Supply, Installation, connection to main earth grid, testing and commissioning of earth pits in hard soil area complete with 40 mm dia & 3000 mm long GI ROD electrode, GI test link, concrete chamber with Cast Iron (CI) cover as inspection chamber including excavation of earth pit. supply of civil material, back filling, numbering of pits, including all labour and materials as per standard drawing complete as per specification of this tender and directions of Engineer-in-charge.
Supply, installation, testing and commissioning of Outdoor Lighting Panel : 415V, TPN, 18 Way, Polycarbonate enclosure material, astronomical timer controlled contactor operated automatic ON/OFF operation for outgoing MCB feeders for outdoor lighting, IP55 with canopy, suitable for outdoor installation. Panel shall be supplied with cable gland for all incoming and outgoing feeders (additionally 6 nos dummy stopper plug of Nickel plated brass material for outgoing feeders). Incomer and outgoing feeders are as follows : Incomer feeder (One number) : 63A, 415V, 4P MCB, R,Y,B Indication Lamp Outgoing feeder (Nine number) : 32A, 415V, 4P MCB with ELCB Outgoing feeder (Nine number) : 16A, 240V DP MCB with ELCB
Supply, Fabr. and inst. of steel Supply, Fabrication and installation of various sizes steel for supports, brackets for miscellaneous electrical equipment, base frames, support for switchgear, supports for outdoor lighting fixtures, hangers, risers, clamps etc. for miscellaneous electrical equipment / items, cable and cable tray supports with rolled MS sections, pipes, plates, strip etc., including shot blasting, welding, bolting, rivetting,supply of necessary anchor bolts and grouting etc. Including surface finish, painting with one coat of 60 micron DFT of inorganic zinc silicate primer, 1 coat of 100 micron Two pack Epoxy HB Poly amide cured, including breaking walls, floors etc. for structures as required, including supply of all G.I hardware materials, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-In-charge. Any item weighing up to 1 kg or less shall neither be measured nor paid.
Lettering and Stenciling of Letter "Lettering and Stenciling of 32 mm height including supply of approved colour of Paint/Paints , painting of tag number of Electrical equipments as specified in specification & by Engineer -In-Charge.Supply of various types of paints, primers, preparation of surfaces by manual, hand tool cleaning, power tool cleaning and application of primer and finish paints for equipments surfaces/concrete surfaces, identification (Equipment name) lettering, stenciling,colour bands, colour coding etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding at all elevations, various locations, labour, materials, tools & tackles, consumables, safety, PPE's, supervision, etc. to complete the work in all respect as per the Painting Specifications drawings, and direction & full satisfaction of owner's/engineer in charge for all types of equipment as specified in the Painting specifications:"
Cable termination LT upto 40mm Termination of cable having outer diameter upto 40mm; CABLE TERMINATION : (Common specification for this & same category of items below) :Termination of armoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Job includes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling in equipment,removal, cutting , fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulation Tapes, Including Supply of cable WP GLAND and LUGS etc complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC.
Cable termination LT above 40mm Termination of cable having outer diameter above 40mm; CABLE TERMINATION : (Common specification for this & same category of items below) :Termination of armoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Job includes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling in equipment, removal, cutting, fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulation Tapes, Incliding Supply of cable WP GLAND and LUGS etc complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC.
Weather Proof Lighting Junction Box Supply, installation, termination of Four (4) Way Weather proof Lighting Junction Box with FRP enclosure material, IP66,Suitable for termination of one number incoming cable size of 4CX6 sq mm, one number outgoing cable size of 4CX6 sq mm and two number outgoing cable size of 3Cx2.5/4 sq mm, cu conductor, armoured, XLPE insulated cables. JBs will be suitable for installation in outdoor street lighting pole.Supply will inclusive of four numbers double compression Nickel plated brass cable gland for incoming and all outgoing cables, one number dummy stopper plug, SS hardwares (SS-304) for mounting / installation
Supply, Installation, Testing and commissioning - 630A Feeder Pillar Feeder pillars with Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self- extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection● 630A MCCB as Incomer Breaker.● 2 Nos 400A MCCB, 2 Nos 250 A MCCB, 4 Nos 63A MCCB, 2 Nos 32A MCCB (timer controlled) outgoing feeders● Supply shall include commissioning spares as required (List shall be provided by bidder). Feeder pillar panels shall comply the following requirement : The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same.# With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2.# The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view.# Routine Test Certificate should be from OEM only
Part-C (Service)
Fabrication and installation of GI pipe Fabrication and installation of of 50 mm dia, class B, GI pipes/ sleeves for cable protection, fixed on steel, concrete or similar structure, in trenches, ready to be buried in concrete including cutting, bending, grinding, threading and similar works, supply & fixing of required GI fastners, clamps,small iron structures, spacers, cleats, plug, bushings, sealing compound/ material etc., cutting and remaking of concrete surface including supply of civil material, all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.
Clearing Grass and Removal of Rubbish Clearing grass and removal of rubbish up to a distance of 30m outside the periphery of the area. By manual means. Grubbing, scrubbing & clearing the areas, removal of roots/boulders, breaking clods, making up the hollow produced by removal of roots/boulders with available earth, clearing the site of all objectionable/unserviceable materials by means of manual or mechanical excavation as per directions of Engineer-in-Charge. Including loading, transport, unloading and disposal of the unserviceable material at designated areas within the plant boundary and leveling the same
Cable laying OD upto 40 mm Laying of cables with outer diameter upto 40 mm. LAYING CABLE : (Common specification for this & same category of items below) : Laying, testing and commissioning of following sizes LV, MV & HV Cables and sealed properly of upto /3.5/ 4 of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.; Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps. etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. (Structural steel, tray, pipe, excavation, sand and bricks shall be paid under separate item of BOQ). Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported back to desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT.
Laying, clamping and connecting of 25 x 6 mm GI earth strip for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Laying, clamping and connecting of 8/10 SWG GI Wire for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Cable laying OD above 40 mm Laying of cables with outer diameter above 40 mm. LAYING CABLE : (Common specification for this & same category of items below) : Laying, testing and commissioning of following sizes LV, MV & HV Cables and sealed properly of upto /3.5/ 4 of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.; Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps. etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. (Structural steel, tray, pipe, excavation, sand and bricks shall be paid under separate item of BOQ). Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported back to desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT.
Shifting of transformer from existing location to new location and installation at new location above civil foundation.Necessary rail supports and supports for installation of the transformer shall be under the scope of the bidder.Crane/hydra/tractor-trailer shall be provided by NRL free of cost. Job shall be executed as per direction of E-i-C
Testing and commissioning of transformers upto 1 MVA,11/0.433 KV ONAN with all labour and materials , as per direction of E-I-C.
Panel etc. install: Weight 101-500 kg.
Part-D (Civil job)
Backfilling with river sand "Backfilling with river sand Backfilling in section excavations for foundation, plinth, trenches etc with riversand supplied by Contractor after excavating the same from approved borrow areas, loading, transporting the sand to site of work, unloading, laying at all depths and heights in layers of 150mm loosethickness, watering and ramming to proper compaction to achieve 85%laboratory maximum dry density, dressing etc. all complete as per directionsof Engineer-in-Charge and including certification of used material incompliance with the Soil Recommendations. Price shall be including cost of backfill material along with all royalties. including Inspections and Tests
Transportation of surplus earth/debris Transportation of surplus earth/debris (excavated earth from item 7.0 above) Carting the surplus excavated earth/rocks and debris from construction area beyond the initial lead of 500 meters to the approved dumping area within the plant boundary including re-excavating deposited soil excavated earlier, transportation, loading, unloading, laying at all depths/heights, stacking, levelling and dressing both the area (viz. from where the earth is carted and where it is deposited) to required levels and slopes complete with all lifts.
LEAN CONCRETE (PCC 1:4:8) Providing and laying in position Plain Cement Concrete 1:4:8 (1 Cement: 4 Coarse Sand: 8 Graded Stone Aggregates) with 40 mm and down size graded stone aggregate as leveling course in foundations, under slabs on grade etc., including tamping, curing, shuttering etc. complete for all depths and heights. For details refer specification for Plain and Reinforced concrete. Materials to be supplied as per approved vendor lists attached with special conditions of contract
M-30 grade of concrete "FOUNDATION CONCRETEProviding and laying in position Reinforced Cement Concrete in open foundations, trenches, precast cover slabs of specified grade( design mix ) with 20mm and down size graded stone aggregates including screening and cleaning of coarse aggregates, fineaggregate (sand) conforming to proper grading, zone, both of approved quality and Ordinary POrtlamnd Cement , as necessary, cost of curing with water, excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and even surface etc. including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control,sampling, testing etc. including cost of all material & labor in substructure, footings and other similar items not specifically mentioned herein, for all depths, complete as per drawings, specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete. Materials to be supplied as per approved vendor lists attached with special conditions of contract.M-30 grade of concrete.
FORMWORK Providing and fixing plywood centring and shuttering straight / inclined, in foundations for footings, rafts, retaining walls, trenches, pedestals, pipe sleepers, culverts, drains, pipe way bridges, tunnels, liquid storage structures etc. including keeping the same in position during concreting and removal of the same after specified period, keeping necessary provision for inserts, projecting dowels etc., tools, equipments and labour necessary for the work all compete, and as specified and directed.
DEFORMED/TMT STEEL BARS FOR CONCRETE Supply and fixing in position TMT reinforcement bars Fe500D conforming to IS-1786 (FY=500 MPa) for RCC work including the cost of steel and cost of binding wire, carting the same to site of work, straightening, cleaning, cutting, binding with 18 SWG black soft annealed binding wire, and placing with proper cover blocks, supports, chairs, spacers, complete for all heights and depths complete as per drawing & specification. Materials to be supplied as per approved vendor lists attached with special conditions of contract. For payment reinforcement including authorized weight for spacer bars, laps, chairs etc shall be measured separately for diameter wise length actually used. Wastages & unauthorized laps shall not be considered for payment. Inspections and Tests as per relevant technical specifications and codes shall be deemed to be included in the scope
Earth work in excavation for all kind of Soil including all labour, materials, dressing of sides, pumping & bailing out water accumulated due to rain and / or subsoil waters and including disposal or stacking, leveling and neatly dressing as decided by Engineer-in-Charge including providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., if any, complete, including shoring/ strutting /sheet pile, all materials and labour complete and as directed by Engineer-in-Charge for following depth.Excavated soil shall be disposed at least 50 m away from the Plant Boundary / kept for backfilling within a radius of 500M and the charges for the same is included in this item.Earthwork in excavation from grade level upto 1.5 m depth"
Earth work in excavation for all kind of Soil including all labour, materials, dressing of sides, pumping & bailing out water accumulated due to rain and / or subsoil waters and including disposal or stacking, leveling and neatly dressing as decided by Engineer-in-Charge including providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., if any, complete, including shoring/ strutting /sheet pile, all materials and labour complete and as directed by Engineer-in-Charge for following depth.Excavated soil shall be disposed at least 50 m away from the Plant Boundary / kept for backfilling within a radius of 500M and the charges for the same is included in this item.Earthwork in excavation from 1.5 m depth from grade level.
Supply and spreading of approved fine river sand in cable trenches including all labour and materials complete as per specifications and direction of Engineer- in-charge.
Supply and laying of approved second class bricks of thickness 3" in cable trenches for cable protection including all labour and materials complete as per specifications and direction of Engineer- in-charge.(Actual area of laid brick surfaces shall be measured).
Supply of sealing compound (Bituminous tar/eqv) heating & pouring of compound in the metallic pipes for providing effective cable sealing.
Supply, fabrication and installation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
Fortune Infratrade Pvt. Ltd.
M/S Nityananda Borah
NORTH EASTERN ENGINEERS
M/S POWER GRID ASSOCIATES
Bajaj Electricals Ltd
N.K. ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .