Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-Finance | ₹16.9 L | L1 | Accepted-Finance Ist Lowest bidder |
| 2 | L2₹17.4 L+₹50,070 (2.96%)Accepted-Finance | ₹17.4 L+₹50,070 (2.96%) | L2 | Accepted-Finance IInd Lowest bidder |
| 3 | L3₹18.7 L+₹1.8 L (10.4%)Accepted-Finance | ₹18.7 L+₹1.8 L (10.4%) | L3 | Accepted-Finance IIIrd Lowest bidder |
| 4 | L4₹18.7 L+₹1.8 L (10.6%)Accepted-Finance | ₹18.7 L+₹1.8 L (10.6%) | L4 | Accepted-Finance IV Lowest bidder |
| 5 | L5₹19.8 L+₹2.9 L (17.3%)Accepted-Finance | ₹19.8 L+₹2.9 L (17.3%) | L5 | Accepted-Finance V Lowest bidder |
| Sl No | Description | Qty | Unit | M/s Ayushi Enterprises L6 | SHREE RAM ENTERPRISES L2 | M/s Raj Kishor Contractor L4 | RAJ ENTERPRISES L5 | GYAS PAL CONTRACTOR L3 | FAGGU RAM & COMPANY L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Detail of Work | |||||||||
| 1.01 | Providing and fixing of Electronic (E/F/& O/C PROTECTION Digitel RELAY with complete housing. | 31 | No | 46,500 ₹14,41,500 | 37,000 ₹11,47,000 Lowest | 37,400 ₹11,59,400 | 46,000 ₹14,26,000 | 37,500 ₹11,62,500 | 44,000 ₹13,64,000 |
| 1.02 | Safely Carriage of 33 KV PT & CT from ESC SRE to site of work including loading and unloading at both ends (distance 0 to 50 KM) | 19 | No | 2,000 ₹38,000 | 4,000 ₹76,000 | 4,900 ₹93,100 | 2,200 ₹41,800 | 5,000 ₹95,000 | 1,500 ₹28,500 Lowest |
| 1.03 | Safely Carriage of 11 KV Outgoing VCB 200/100/5A/11 KV Incomming VCB 300/600/5A from ESC SRE to Site of work including loading and unloading at both ends. | 8 | No | 12,000 ₹96,000 | 12,000 ₹96,000 | 13,950 ₹1,11,600 | 11,000 ₹88,000 | 14,000 ₹1,12,000 | 4,000 ₹32,000 Lowest |
| 1.04 | Safely Carriage of 11 KV TPMO from ESC SRE to site of work including loading and unloading at both ends (distance 50 KM) | 3 | No | 1,500 ₹4,500 | 3,000 ₹9,000 | 3,900 ₹11,700 | 1,800 ₹5,400 | 4,000 ₹12,000 | 500 ₹1,500 Lowest |
| 1.05 | Safely Installation of 11 KV TPMO with polymer pin insulator and connection properly. | 3 | No | 1,500 ₹4,500 | 3,000 ₹9,000 | 3,900 ₹11,700 | 1,800 ₹5,400 | 4,000 ₹12,000 | 500 ₹1,500 Lowest |
| 1.06 | Safely Installation of 11 KV Outgoing VCB/Incomming VCB and connection properly. | 8 | No | 12,500 ₹1,00,000 | 13,500 ₹1,08,000 | 14,400 ₹1,15,200 | 11,000 ₹88,000 | 14,500 ₹1,16,000 | 5,000 ₹40,000 Lowest |
| 1.07 | Water Earthing of 11 KV VCB by boring of 60 Ft deep & fixing of 60 ft. G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 40x5 mm and G.I wire at bottom of G.I pipe to the 11 KV VCB providing of required charcoal & salt in the pipe | 4 | No | 22,000 ₹88,000 | 20,000 ₹80,000 Lowest | 23,000 ₹92,000 | 22,500 ₹90,000 | 22,000 ₹88,000 | 20,000 ₹80,000 Lowest |
| 1.08 | Safely installation of 33 KV Outdoor PT (33KV/110 Volt) and connection properly. | 10 | No | 2,500 ₹25,000 | 3,000 ₹30,000 | 3,900 ₹39,000 | 2,800 ₹28,000 | 4,000 ₹40,000 | 1,500 ₹15,000 Lowest |
| 1.09 | Safely installation of 33 KV CT (200/100/1-1-1A) and connection properly. | 9 | No | 2,500 ₹22,500 | 3,000 ₹27,000 | 3,900 ₹35,100 | 2,800 ₹25,200 | 4,000 ₹36,000 | 1,500 ₹13,500 Lowest |
Tender Value
₹17.5 L
EMD Value
₹18,000
Closing Date
11 Jun 2026, 12:00 pmClosed
Superintending Engineer
EDC I Saharanpur
Electrification work of Business Plan 2026-27
2026_PVVNL_1153049_1
10/W/EDC-I/SRE/2026-27
Open Tender
Electrical Works
Lump-sum
45 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Yes
SE EDC I SRE
₹18,000
Yes
20 Jun 2026
25 May 2026
11 Jun 2026
25 May 2026
11 Jun 2026
25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Detail of Work | |||||
| 1.01 | Providing and fixing of Electronic (E/F/& O/C PROTECTION Digitel RELAY with complete housing. | 31 | No | - | - |
| 1.02 | Safely Carriage of 33 KV PT & CT from ESC SRE to site of work including loading and unloading at both ends (distance 0 to 50 KM) | 19 | No | - | - |
| 1.03 | Safely Carriage of 11 KV Outgoing VCB 200/100/5A/11 KV Incomming VCB 300/600/5A from ESC SRE to Site of work including loading and unloading at both ends. | 8 | No | - | - |
| 1.04 | Safely Carriage of 11 KV TPMO from ESC SRE to site of work including loading and unloading at both ends (distance 50 KM) | 3 | No | - | - |
| 1.05 | Safely Installation of 11 KV TPMO with polymer pin insulator and connection properly. | 3 | No | - | - |
| 1.06 | Safely Installation of 11 KV Outgoing VCB/Incomming VCB and connection properly. | 8 | No | - | - |
| 1.07 | Water Earthing of 11 KV VCB by boring of 60 Ft deep & fixing of 60 ft. G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 40x5 mm and G.I wire at bottom of G.I pipe to the 11 KV VCB providing of required charcoal & salt in the pipe | 4 | No | - | - |
| 1.08 | Safely installation of 33 KV Outdoor PT (33KV/110 Volt) and connection properly. | 10 | No | - | - |
| 1.09 | Safely installation of 33 KV CT (200/100/1-1-1A) and connection properly. | 9 | No | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
10w26-27N.pdf
Tender Documents • 1.30 MB
BOQ_2160019.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .