Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.9 L+₹5.3 L (42.0%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹40,600
Closing Date
19 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PATIALA
HQ CWE PATIALA BLDG NO 26 NEW LAL BAGH PATIALA 147001
REPAIRS MAINT OF HT LT ELECT INSTALLATION AND DISTRIBUTION NETWORK INCLUDING DAY TO DAY MAINT OF HT LT NETWORK SYSTEM AT MIL STN NABHA UNDER GE SOUTH PATIALA
2021_MES_442788_1
8321/PAT/T-17/21-22
Open Tender
Electrical and Maintenance Works
Lump-sum
180 days
PATIALA
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE SOUTH PATIALA
₹40,600
Yes
12 Jul 2021
13 May 2021
22 Jun 2021
13 May 2021
19 Jun 2021
31 May 2021
13 May 2021 - 20 May 2021
60 days
Amount
Schedule 'A'Section-I (EXINTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Sec I (ExInternal Electrification Works)
"Attending day to day HT/LT electrical repair work in the Jurisdiction of AGE E/M Nabha cantt area scattered within 01 KM radius intimated by Eng-in-Charge,JE,SBA by deploying dedicated team of adequately qualified electricians and helpers having good knowledge & experience of HV/LV line and fault rectification, under the area of Nabha Mil station For attending the following nature of complaints :-
Replacement of HT fuse wire all as directed and specified by Engr in Charge
Repair/replacement of HT Jumper all as directed and specified by Engr in Charge
ReLaying of cable after excavation for extension of loop for making connection with LT panel/Pole size up to 95 sqmm all as directed and specified by Engr in Charge Note: Excavation required for job shall be measured under respective item of Sch.
Repair/replacement of GOD male/female contact (set of 3) all as specified and directed by Engr in Charge.
Repair / maintenance of HT line and fault finding all as specified and directed by Engr in Charge
Repair / maintenance of LT line and fault finding all as specified and directed by Engr in Charge
Repair/replacement of LT Jumper all as directed and specified by Engr in Charge
Trimming of tree branches required during fault rectification upto the distance of 1.5 mtr from pole/span all as directed and specified by Engr in Charge
Connecting /disconnecting of air-conditioner in married officers quarters, OTM, offrs Mess from the existing over head lines all as directed and specified by Engr in Charge.
Balancing of load on each transformer
Notes:- (a) Contractor will provide all T & P, communication device (Mobile Phone) to deployed persons required for repair of HT/LT Electrical switch gear including safety equipment such as All type of T&Ps (Bamboo ladders, screw drivers, wire/cable cutters with blades, multi meters, cutting pliers, torch lights etc) for routine maintenance and protection of the trademan as well as daily activity incl safety dress, , Hand gloves, Rubber boots, Sefety belt and helmets etc, complaint register, Job card and necessary transportation required for attending complaints/fault/brake downs duty will be provided by the contractor without any extra cost. (b) On intimation of any type of fault tripping of HT/LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out with in reasonable time as given by the Engineer-in-Charge. (c) Periodical maintenance of following feeders which includes trimming of tree branches which are touching with HT and LT feeders and over head line, maintenance of GOD ,jumpers , maintenance of defective disc or pin type insulators ,tightening of jumpers, fixed and moving parts of GODs ,restretching of HT/LT overhead line conductors falling due to collapses of conductor or any other reason incl periodical maintenance of LT panels, security lights feeders etc (Whatever stores are required will be provided by the deptt). Old material retrieved shall be deposited by contractor in MES store yard. (d) periodical maintenanace of HT/LT switch gear incl transformer 11KV/415 volts up to rating 500 KVA (e) Connecting /disconnecting of air-conditioner in married officers quarters, OTM, offrs Mess from the existing over head lines as directed by JE/Engineer in charge.
Taking up/down worn out/damaged/unserviceable XLPE /PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size HT/LT from trench/duct/pole/wall/pipes etc. complete all as specified and directed.
Restringing, tightening of ACSR conductor of any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminum binding wire on LT over head lines and fixing of GI conductor complete all as specified and directed.
Supply and fix in replacement of existing unserviceable MCCB 4 pole, 415 V, Adjustable thermal type 200 Amp with braking capacity 25 KA.
Supply and fix in replacement of existing unserviceable MCCB 4 pole, 415 V, Adjustable type 315 Amp with braking capacity 36 KA .
Material and labour for Cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to much the existing surface level complete all as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
Material and labour for servicing of HT 11 KV VCB 400Amps alongwith CTs/PTs of any make and type by drawing out breaker assy from panel and carry out the following maintenence/repair work- (a) Cleaning/decarbonizing of all fixed and moving contacts, levers, springs by using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (b) Adjustment of the trolley / racking mechanism , (c) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turnig, polishing of main and auxiliary contact, demoisturing of insulators, etc. (d) Testing of tripping performance of HT VCB by using primary & secondary high current injection, test including measuring of CT ratio and polarity all as directed. (e) Resetting of tripping relay including interlocking system. (f) Checking of operating mechanism and its adjustments, measurements of the mechanical clearances of operating mechanism, internal wiring circuit, tightening of all electrical connections including removing moisture content complete all as directed.
Painting to existinfg PCC poles 9 / 11 meters long with one coat of synthetic enamel paint in alternate strips of yellow and black colour 30 cm height each total 05 Nos commencing from the top of PCC coping, including painting of cross arms, nut bolts, clamps etc as fixed on pole with two coats of aluminium paint and marking pole No with paint as per approved pattern complete all as specified and directed. Note : Numbering shall be hand written only, size of letter 100 x 10mm(Height x Width).
Disconnecting carefully of HT/LT connectiones, taking down transformer 63 to 400KVA 11KV/415V from mounting platform and transporting to authorised workshop (as per direction of Engr-in-charge) to carryout the following repair/replacement :- (a) Opening of transformer, taking out the core and coil from housing, drain out oil in drum for reuse, after dehydration. (b) Rewinding of HT/LT coil of transformer with super enamelled copper/ aluminium winding wire of appropriate guage varnishing drying wrapping at the top connections with impregnated tape refixing the core and coil assembling upto the transformer housing including replacing gasket(Approx 40Kg copper Coil) including varnishing and drying the complete coils and fix into position complete all as specified and as directed. (c) Cleaning washing heating the coil in vacum to achieve the coil insulation upto minimum 200 mega ohm. (d) Dehydration of transformer oil to achieve the dielectiric strenght upto 40KV at 2.5mm gap (Approx 200 Ltrs). (e) Replacement of HT/LT bushing with bushing rod.
Supply only Double paper coating(D.P.C) HT insulated copper winding wire of existing guage/size including varnishing and drying the complete coils and fix into position complete all as specified and as directed. Note : Actual weight of bare copper conductor shall be measured and paid.
Supply only Double paper coating(D.P.C) LT insulated copper winding wire of existing guage/size including varnishing and drying the complete coils and fix into position complete all as specified and as directed. Note : Actual weight of bare copper conductor shall be measured and paid.
Supply only HT bushing suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only LT bushing suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only 12mm dia HT bushing rod with superior quality bushing insulator suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only 20mm dia LT bushing rod with superior quality bushing insulator suitable for 63 to 400 KVA outdoor/ indoor type transformer - (set of three) complete all as specified and as directed.
Supply only silica gel suitable for 63 to 400 KVA outdoor/ indoor typet ransformer complete all as specified and as directed.
Supply only inspection glass and gasket of conservator suitable for 63 to 400 KVA outdoor/ indoor type ransformer complete all as specified and as directed.
Material and labour for dehydration of transformer oil at site using dehydration/ filtration plant to achieve dielectric strength not less than 40KV at 2.5mm gap and testing for strength including recording results all as specifed and directed. NOTE: (i)The contractor shall submit dielectric strength report after filtration and dehydration of each transformer (ii) Rate to be quoted will be inclusive of transportation of dehydration machine to Military Station at various location where transformer installed.
Supply only transformer oil confirming to IS-335-1993 at site for topping up to oil level transformer of existing transformer installed at various location having dielectric strength not less than 50KV at 4mm gap complete all as specifed and directed. NOTE: Transformer oil shall be brought in manufacturer sealed drum at site.
Materials and labour for spray painting of transformer by using spray gun with two coats of Duco paint (Grey) after cleaning thoroughly and preparation of surface of transformer of capacity exceeding 60KVA and upto and including 400 KVA including writing of MES No/SM No complete all as specifed and as directed.
Supply and fix LT Spacer 02/03/04 way spiral type made out of PVC material and suitable for to work on 1100 volts fixed between 03 conducters in any position along the LT line for any size of conductor complete all as specified and directed
Jawandha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .