Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Dec 2020, 3:00 pmClosed
Store Officer (CNC), AIIMS
Store Officer (CNC), Store Section (CNC), N.P Ward, AIIMS
As per Tender Document
2020_AIMSD_591819_1
74/CNC/CTVS/2020-21/ST.
Open Tender
Medical Equipments/Waste
Buy
180 days
CNC AIIMS, NEW DELHI
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹50,000
Yes
Seminar room 7th floor Room No. 18 CTC,CNC,AIIMS N
25 May 2023
20 Oct 2020
8 Dec 2020
20 Oct 2020
7 Dec 2020
20 Oct 2020
20 Oct 2020 - 17 Nov 2020
11 Nov 2020
Purchase of Diff.types of consumable valves,rings &conduits items for CTVS Department on 2 year Rate Contract Basis Part II
Bovine Jugular Vein Conduit (Size 22) • Suitable for reconstruction or replacement of the natural right ventricular outflow tract (RVOT). • Un-stented • Preserved in buffered glutaraldehyde • No thawing or preclotting should be required • Trileaflet venous valve
Bio prosthesis Stented Porcine (Mitral) (All sizes) • Should be latest generation Native asymmetrical Porcine tissue valve, • Should have more than fifteen-year durability clinical data, • Should have AOA tissue treatment to mitigate calcification & Physiological fixation • Should have Flexible acetyl homopolymer stent& Cinch II Implant system
Bio prosthesis Stented Porcine (Aortic)) (All sizes) • Should be latest generation Native asymmetrical Porcine tissue valve, • Should have more than fifteen-year durability clinical data, • Should have AOA tissue treatment to mitigate calcification & Physiological fixation • Should have Flexible acetyl homopolymer stent& Cinch II Implant system
Bovine Pericardial, Suprannular Aortic Valve (all sizes) • Should have AOA tissue treatment to mitigate calcification & Physiological fixation • Should have three laser cut pericardial leaflets. • Soft and pliable sewing cuff. • Lower valve profile and narrow commissure posts • Streamlined valve holder to improves visibility in both standard and minimally invasive approaches. • Simple one-cut release • Base frame impregnated with Barium Sulphate
Artificial heart valve, bileaflet, mechanical, mitral, all sizes • Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. • Should have low profile height. • Should have minimum vertical leaflet exposure to result in NO LVOT obstruction • Should have greater posterior wall clearance • Wide range of sizes. • Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.
Artificial heart valve, bileaflet, mechanical, aortic, all sizes • Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. • Should have low profile height. • High performance index. • Wide range of sizes. • Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.
Artificial heart valve, bileaflet, mechanical, supra-annular, aortic, all sizes • Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. • Should have low profile height. • High performance index. • Wide range of sizes.Size 16 or smaller should be available. • Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.
Artificial heart valve, bileaflet, mechanical, intra-suprannular, aortic, (Sizes 17-25) • Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. • Should have low profile height. • High performance index. • Wide range of sizes. • Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.
Bileaflet mechanical aortic valve with Dacron conduit (All sizes) • Should have double velour woven graft. • Should be collagen impregnated to control haemostasis and reduce the haemorrhagic complications. • Should have mechanical heart valve with low-pressure gradients. With pivot guard design and leaflet opening and >75 degrees. • Cuff design should enhance implantability. • Should have minimum taper conduit to facilitate strong coronary anastomosis. • Should not have any pleats to allow easier positioning and attachment of the coronary arteries. • Wide range of sizes from 19mm- 33mm.
Expanded cuff, Bileaflet mechanical aortic valve with Dacron conduit (All sizes) • Should have double velour woven graft. • Should be collagen impregnated to control haemostasis and reduce the haemorrhagic complications. • Should have mechanical heart valve with low-pressure gradients. • Expanded cuff for ease of suturing. • Should have minimum taper conduit to facilitate strong coronary anastomosis. • Should not have any pleats to allow easier positioning and attachment of the coronary arteries.
Monoleaflet, tilting disc, mechanical, Mitral, All sizes. • A monolithic frame carved out of a single block of Chrome Cobalt alloy. • An occluder made from touch and durable Ultra High Molecular Weight Polyethylene. • Should provide silent operation and low cavitation. • A sewing ring made from knitted Polyester. • Supra-annular design. • Rotatable • Rotatable
Monoleaflet, tilting disc, mechanical, Mitral, All sizes • A monolithic frame carved out of a single block of Chrome Cobalt alloy. • An occluder made from touch and durable Ultra High Molecular Weight Polyethylene. • Should provide silent operation and low cavitation. • A sewing ring made from knitted Polyester. • Intra-annular design. • Rotatable
Percutaneous Aortic Valve system of size 23-34MM with Supra-Annular Self Expanding Nitinol frame with Porcine Pericardium with compatible delivery catheter and loading system (Prototype Evolut R, Medtronic)
Percutaneous Aortic Valve system of size 23-34MM with Supra-Annular Self Expanding Nitinol frame with Porcine Pericardium& external skirt with compatible delivery catheter and loading system ((Prototype Evolut Pro, Medtronic)
Percutaneous Aortic Valve of Size 20- 29 MM with Intra-annular Balloon Expandable cobalt-chromium frame with bovine pericardial tissue with compatible delivery catheter and loading system (Prototype: SAPIEN 3 / Myval )
J. Mitra & Bros.
India Medtronic Private Limited
GENESEE MEDICALS
India Medtronic Private Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .