Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.9 LQualified Make: BPE
Model: 6KVA UPS with 60 minute 8500 VAH I 92B 1 ST FLOOR VIVEK GUGNANI I 92 1ST FLOOR LAJPAT NAGAR 2 98100 NEW DELHI DELHI 110024 UDYAM DL 09 0003779 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: 6KVA UPS with 60 minute 8500 VAH | ₹3.9 L | L1 | Qualified |
| 2 | L2₹4.6 LQualified Make: Delta
Model: DELTA ONLINE UPS- 6 kvA WITH 60 MINS BACKUP | Make: Delta
Model: DELTA ONLINE UPS- 6 kvA WITH 60 MINS BACKUP | ₹4.6 L | L2 | Qualified |
| 3 | L4₹4.9 LQualified Make: UTL
Model: UTL ALFA ONLINE UPS | Make: UTL
Model: UTL ALFA ONLINE UPS | ₹4.9 L | L4 | Qualified |
| 4 | L5₹5.2 LQualified Make: KEPTRON
Model: KEPTRON-KE440/6602 | Make: KEPTRON
Model: KEPTRON-KE440/6602 | ₹5.2 L | L5 | Qualified |
| 5 | L6₹5.2 LQualified Make: BPE
Model: BPE 6KVA 8500VAH ONLINE UPS 2YRS UNIT NO 125 MASTERMIND 1 ROYAL PALMS AAREY COLONY GOREGOAN MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 6KVA 8500VAH ONLINE UPS 2YRS | ₹5.2 L | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Oct 2018, 3:00 pmClosed
Online UPS ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 6.0 KVA 6.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 8500 400-640000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP21 IP21 Cabling 5 meters for input and out put Without With
Without 1/4 Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes * Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vikas Umrao Katakdhond 411007
Rajbhavan Complex
Baner Road
YASHADA
Pune 5 15
676684
GEM/2018/B/95923
Online UPS
15 days
Maharashtra; Pune
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 6.0 KVA 6.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 8500 400-640000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP21 IP21 Cabling 5 meters for input and out put Without With | - | - | - |
| Without 1/4 Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vikas Umrao Katakdhond 411007 | - | - | - |
| Rajbhavan Complex | - | - | - |
| Baner Road | - | - | - |
| YASHADA | - | - | - |
| Pune 5 15 | - | - | - |
Exempted
10 Oct 2018
10 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_676684.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].