Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹52.6 L+₹5.7 L (12.1%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹53.7 L+₹6.8 L (14.4%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹54.7 L+₹7.7 L (16.4%)Rejected-Finance H NO 243 VARADARAJ NAGAR VIDYARANYAPURA POST BANGALORE 560 097 | BANGALORE | BANGALORE | KARNATAKA | 560097 | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹56.1 L+₹9.1 L (19.4%)Rejected-Finance | L5 | Rejected-Finance rejected being L5 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
28 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D East Bangalore
GE I RD East Bangalore 93
PROVN OF 02 NOS OF RAIN WATER HARVESTING CHAMBERS AT CEMILAC AND RCMA BUILDING AND CERTAIN SANCTIONED WORKS UNDER GE I RD EAST BANGALORE
2020_MES_367379_1
8967
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D East Bangalore
D a (i) b (i) c (ii)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹86,000
Yes
6 Nov 2020
7 Aug 2020
2 Sept 2020
7 Aug 2020
28 Aug 2020
22 Aug 2020
8 Aug 2020 - 19 Aug 2020
60 days
Amount
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for
S&F PVC sheets in repairs 2mm thick laminated plain coloured marbled mosiac or mottled finish laid with approved rubber based adhesive in floors and skirting complete all as specified and as directed
M&L PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in flooring 40mm thick finished even and smooth without using extra cement complete all as specified and as directed
M & L for glass dividing strips 3mm thick 38mm wide inserted in floors conforming to design.
M & L PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair complete all as specified and as directed
Taking down chowkhats or frames with shutters (without taking off shutter from the frame ) wooden not exceeding 1.5 Sqm each.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame ) wooden exceeding 1.5 Sqm but n exc 4Sqm each.
S & F for solid PVC door frame Ivory colour of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube in opening including fixing lugs, hinges etc complete all as specified.
S & F factory made solid panel PVC door shutter Ivory colour 30 mm thick style consisting or frame made out of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the style & rails with suitable PVC sheet beading and jointed together with solvent cement supply and fixing in the frame at site including PVC bow handle tower bolts and hinges complete all as specifed.
S & F 2nd class soft wood, plain solid straight chowkats and frame wrought framed rebated on the solid rounded or chamfered put together with glue pinned and joints all as specified and directed.
S & F 2nd class soft wood plain framed panelled shutters (any No of pannels ) 40 mm thick with panel of timber flat on both sides (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers as in doors all as specified and directed.
S & F Glazed and skelton shutter Ist class soft wood 30 mm thick open rebated and prepared to receive glass gauge etc ( without sash barrs) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members all as specified and directed.
S & F 30 mm thick Ist class Hard wood skelton shutters, divided into squares with plain, chamfered or rounded mitred and rebated sash bars for windows,ventilator any numbers, size of stiles and rails as specified in SSR (1991) Part-I section 8 clause 8.20 (b).
S & F 50 mm butt hinges medium weight cold rolled mild steel
S&F 100mm size aluminium anodised barrel tower bolts of extruded section.
S & F 100 mm butt hinges medium weight cold rolled mild steel
S&F 150mm size aluminium anodised barrel tower bolts of extruded section.
S&F 250mm long aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cost or extruded sections and fixings bolts and slilding bolts of extruded sections and fixing bolts and sliding bolts of extruded section or case aluminium alloy.
S&F 150mm size aluminium handle cast type anodised.
S&F Galvanised MS wire cloth 0.63mm nominal dia wire cloth average width aperture 1.40mm and fixed with tinned tack or GI wire staple.
Dismantling floor, hearth or wall tiling including cement mortar bedding (not backing) removing serviceable tiles to store and rubbish off the premises.
Removing demolition meterial exc 1.5Km and n exc 5.0Km depositing where directed at a level n exc 1.5 m above starting point.
M&L for PCC 1:2:4, type B1, 25 mm thick (using 20 mm graded stone aggregate) as in flooring/ paving finished rough to receive cement tiles complete all as specified and as directed
M & L for screed bed for bedding layer of mortaor 15 mm thick for laying floor finishes in cm 1:6 complete all as specified and as directed
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
Material and labour for glazed coloured ceramic tiles in vertical surfaces for wall tiles of size 450 x 300 x 7 mm thick as in dados, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles with joint free.
M & L for rendering 10 mm thick in cement mortaor 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed
Supply and fixing in repairs vitreous china squatting pan 'Orissa' pattern size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush etc) Make : CERA
S & F in repairs Vitreous china wash basin angle back (Oval type) size 600 x 480 mm white excluding taps waste chain and plug and porcelain stopper including cutting for and pinning in ends of brakets or eracting stand , waste pipe Make : CERA
S & F in repairs pillar taps, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed
Supply and fix in repairs PVC valveless, symphonic action type, flushing cistern low level, white with inlet ball valve float and valve float and handle including brackets 10 ltrs capacity Make : CERA
Supply and fix in repairs flush pipe of polyethylene of high density of PVC 32 mm for low level cistern complete all as specified and as directed
Supply and fix in repairs vitreous china urinals, size 635 x 395 x 420mm, white, half stall type, complete. Make : CERA
Supply and fix in repairs brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing union cap and fixed 32 mm complete all as specified and as directed
Supply and fix in repairs PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed
Supply and fix in repairs for push tap any colour high pressure of PTMT screwed for iron pipe and fixed suitable for urinals (Minimum weight 15 mm - 50 gms) 15 mm dia
Supply and fix in repairs for urinal spreader of PTMT any colour for fiing with 15 mm dia pipe (Minimum weight 60 gms, complete all as specified and as directed
Supply and fix in repairs stop valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe, fancy type chromium plated, 15 mm size complete all as specified and as directed
Taking up or down steel tubing and connections 15 mm dia
Taking up or down steel tubing and connections 20 mm dia
Supply and fix tubes medium grade, galvanized, with all fittings and fixed complete to walls and ceiling or laid in floors 15 mm bore.
Supply and fix tubes medium grade, galvanized, with all fittings and fixed complete to walls and ceiling or laid in floors 20 mm bore.
Supply and fix UPVC (SWR) floor trap 125/110 mm setting and jointing with solvant cement fixed complete.
Taking down UPVC (SWR) pipes any dia.
Supply and fix UPVC (SWR) pipes single socketed 110 mm bore laid in floor trenches/wall.
Supply and fix UPVC (SWR) pipes single socketed 75 mm bore laid in floor trenches/wall.
Supply and fix in repairs bib taps, fancy type, chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed 15 mm fixed
Supply and fix towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms)
Supply and fix PTMT 450mm towel rail fixed with and including chromiume plated brass screw wooden/plastic cleats.
Dismantling of water tanks and removing to store 1000 ltrs.
S & F for rotational moulded polyethylene water storage tanks 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I
Suply only integral water proofing compound.
M&L for pcc 1:2:4 type B0, 25 mm thick (using 12.5 mm graded stone aggregate) as in roof padding finished even and smooth complete all as specified and as directed
M&L APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (Weight not less than 150 gms/Sqm) laid on primed surfaces by forced application incl bituminous primer confirming ot IS-3384 applied @ 0.3 ltr/Sqm and applying aluminium paint @ 100 ml/Sqm including taking down old treatment complete all as specified and directed. Four course of roof treatment consist of as under :- (a) Applying one coat of bituminous primer conforming to IS 3384 @ 0.3 ltr/Sqm (b) Laying of APP based membrane as specified thickness and weight. (c) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm. (d) Applying one coat of aluminium paint @ 100ml/Sqm.
Demolition of brick or stone / concrete block / stone boulder masonry built in cement mortar incl all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles.
M&L brick work with sub class B brick,straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed
M&L Dura stone tile size 300x300x15-20 mm thick laid over 15mm thick cm 1:6 complete all as specified and directed.
Taking down plastering on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc.
M&L Rendering 15 mm thick stone masonry wall surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed
M & L Rendering 10 mm thick on fair faces of concrete surface finished even and smooth without using extra cement in CM (1:4) rendering complete all as specified and as directed
M&L applying 2 coats of Exterior emulsion weather proof paint over a coat of primer incl new plastered wall surfaces including prepration etc all as specified and directed (Make/Brand Name : Asian Paints(Apex ultima), Berger Paints(Weather coat All Guard)
M&L prepration of new surface on wall and applying two coats of white wash complete all as specified and as directed
S&F Steel rooling shutters with gear oprated type with bevel gear box and crank handle thickness of lath 1.25mm including top cover anchring rod haps and staple and one shop coat of primer erected in position including taking down old rooling shutter complete.
Taking down Steel rooling shutters and refixing in same opening after greasing ,oiling making good smooth functionand painting one coat of synthetic enamel paint any size of shutter , complete all as specified and directed.
M & L Prepration of new surface of any description, over 10cm in width or girth, not otherwise described, two coat synthetic enamel paint over a coat of red oxide primer on iron surfaces complete all as specified and as directed
M & L Prepration of old surface of any description, over 10cm in width or girth, not otherwise described, one coat synthetic enamel paint on iron surfaces complete all as specified and as directed
M & L Prepration of new surface of any description, over 10cm in width or girth, not otherwise described, two coat synthetic enamel paint over a coat of pink primer on wood surfaces complete all as specified and as directed
M & L Prepration of old surface of any description, over 10cm in width or girth, not otherwise described, one coat synthetic enamel paint on wood surfaces complete all as specified and as directed
M&L prepration of old surface on wall and applying one coats of white wash complete all as specified and as directed
M&L prepration of old surface on ceiling and applying one coat of white wash complete all as specified and as directed
M&L applying ONE coats of Exterior emulsion weather proof paint on wall old surfaces including cornices, plasters etc by scrapping/down with wire brushes and washing down and removing existing loose finishes particles etc all as specified and directed (Make/Brand Name : Asian Paints(Apex ultima), Berger Paints(Weather coat All Guard)
M&L prepration of old surface on wall and applying one coat of distemper oil emulsion complete all as specified and as directed
Hacking out old brocken glass of any thickness size quality or description from wooden frame or stone concrete or brick.
S & F sheet glass 3mm thick for window ordinary quality frosted on one side in n.exc 0.5 Sqm in each pan with rubber beading as in doors and partitions complete all as specified and as directed
Excavating over Area, n exc 1.5 m deep in soft/loose soil complete all as specified and as directed
Excavating over Area,exc 1.5 m but n.exc 3m deep in soft/loose soil complete all as specified and as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm
Removing of excavated materials to a distance exc. 5 KM, but n.exc 10.0KM and depositing out side MD land.
M&L Cement concrete in foundation filling and mass concrete in type D2, 1:4:8 (using 40 mm graded stone aggregate)
M & L for Walling of random rubble (Bangalore type), regular coursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed
Hard core of gauge n.exc 0.63mm,deposited,sptred and levelled in layer n.exc 15cm thick,watered and rammed to a true surface.
M & L for RCC of grade M-20 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M & L for RCC of grade M-20 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and as directed
M & L Pre cast factory made perforated RCC in 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed
M & L for RCC of grade M-20 as in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed
S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Formwork (Rough finished) to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter
Formwork (fair finished) to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all n.exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening.
M&L PCC 1:3:6 type C -2 (using 40 mm graded stone aggregate) 75 mm thick as in Plinth protection, complete all as specified and as directed
M & L for 10 mm thick rendering in cement mortar 1:4 on fair surfaces of brick or concrete work complete all as specified all as specified and directed.
M&L for preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and directed.
Preparation of new or previously untreated surfaces & priming with red oxide and applying two coats of synthetic enamel paint of any description, over 10 cm in width or girth, not otherwise described
S & F Mild steel work as in doors or gate of angle Rungs in static tank of other section gusset plate rails ladder & Hand rail including welding securing bolts including cutting tops to shape as directed, drilling holes etc conforming to Fe 410 -O or Fe 310 - 0, complete all as specified and directed by Engineer-in-Charge
Material and Labour for sand filling under floor including watering, consolidation, and complete all as specified and as directed.
M&L for providing PCC 1:2:4, type B1 in coping (using 12.5mm graded stone aggregate) including necessary form work complete all as specified and as directed
Supply and fix UPVC (SWR) pipes single socketed 110mm mm bore laid in floor or trenches.
Supply and fix UPVC (SWR) pipes single socketed 110mm mm bore laid in wall.
Supply and fix UPVC (SWR) bends110mm mm bore.
Excavation in post holes each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance n exc 50m and making goof surface in hard / dense soil.
M & L Brick work with sub-class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed
M & L PCC 100 mm thick 1:3:6, type C2 (using 40 mm graded stone aggregate) as in sub base flooring complete all as specified and as directed
M & L 100 mm thick, cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate), finished even & smooth, using extra cement, as in floors, complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering fixed with self tapping screws as specified. Note : (Height up to 15Mtr and above/factory type bldg/Hangar)
All as per item No 108 here-in-before, but plain sheet for ridge complete all as specified and as directed
S&F Joist, channel, angle or tee sections fixed independently without connecting plates etc. complete all as specified, conforming Fe 410W (Gde E-250) Quality B.
S&F framed work such as grilling fancy type, gratings with ends of bars shouldered or riveted or forged into spikes, framed guard bars, barred iron doors etc.
M&L for PCC 1:3:6, type C2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete.
Taking down carefully of any type point wiring light fans socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc removing material and making good disturb surface of wall floor etc complete all as directed.
Point wiring concealed type complete with 1.5 sqmm PVC insulated unsheathed and multi stranded copper conductor(Make : Havells/Finolex/RR kabel) PVC conduit 20 mm bore having 2 mm wall thickness with all conduit accessories for one light /fan/buzzer/soket outlet point controlled by one switch including continuous 1.5 sqmm copper conductor, stranded (green colour, earth), PVC insulated unsheathed earth wire to common earth and connected to earth dolly to be terminated in and including suitable size module boxes for housing of module switches/sockets etc complete all as specified and directed Note : Unit rates quoted by contractor shall be deemed to included for cutting chases in walls and making good in cement morter (1:3) and finishing the surface to match with exisiting surface.
a) One light point controlled by one 5 Amps one way switch
b) One celing fan point/EXHAUST FAN controlled by one 5 Amps one-way switch and regulator.
d) One 3 pin 5Amps switch socket outlet point on independent board
(e) One 3 pin 5Amps switch socket outlet point on same board .
All as per item No. 115 here in before, but 2.5 Sqmm copper conductor wiring wiht 1.5 Sqmm copper conductor as earth continuity for 15 /16Amps socket out let on independent board.
Supply and fix switch modular type single pole one way 6 Amps including suitable size of module cover with frame.
Supply and fix switch modular type single pole one way 16 Amps including suitable size of module cover with frame etc.
Supply and fix socket outlet 2/3pin 6 Amp modular type including suitable size of cover with frame.
Supply and fix socket outlet 6/16Amp 2/3 pin with suitable size of cover with frame.
Supply and fix modular fan regulator
Taking out submain wiring of any type and size and any capacity including batten /conduit /casing caping for renewal/replacement and making good the distrubed surface as per existing all as specified and directed
M&L for sub main wiring complete with 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends including provision of 1 run of 1.5 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly .
Supply and fix in replacement ceilling rose, surface backlite PVC/Polycarbonate, insulated body 2 to 3 terminal 240Volts , 5 Amps, complete all as specified.
M & L for taking down tube light fittings /bldg light fittings of any type ,any make and capacity from wall all as specified and directed
Supply and fixing LED street light fittings of 45W made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD complete with all accessries like nuts and bolts ,clip etc at wall, pole, roof all as specfied and directed. Make: Havells /philips/Crompton greaves
Supply and fixing Surface and wall mounted LED tube light fittings of cap 20W,Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver all as specified and directed by EIC. Make : Havells /CG/Philipsequivallent in Philips
Taking out old unserviceable distribution board of any size and any capacity including making good the distrurbed surface with existing surface complete all as specified and directed
S&F in replacement Sheet steel metal enclosure TPN 415 Volts 4 Way distribution box double door, suitable for fixing MCB as outgoing and MCCB TP 63 Amp 16 KA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts angle iron and making good disturbed surface all as specified and directed. Note :- MCCB TP shall be measured and paid seperately. MAke Legrand/C&S/Havells
Supply and fixing MCB TPN 63 Amp . Make : Legrand/Havells/Schneider
Supply and fixing MCB TPN 32 Amp . Make : Legrand/Havells/Schneider
S&F in replacement Sheet steel metal enclosure distribution box double door, SPN MCB DB double door SPN for MCB 8 Way 240Volts, flush mounting CRCA powder coated with 200 Amps rated bus bar. Make : Legrand/C&S/Schneider
S&F in replacemet MCB SPN 10 Amp to 40 Amps Make:- Legrand/Havells/Schneider
S&F in replacement MCB SP 240 Volts 10 amp to 40 Amps Make:- Legrand/Havells/Schneider
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised earth lead wiree 4 mm dia by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long, etc complete all as specified.
Earthing complete with galavanised plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25M below ground level with the top edge of earth plate at a depth of not less than 1.5m below normal ground level connected to earth lead of 32 x 6mm GI strip by means of bolts, nuts, check nuts, washers of GI and GI strip, protected by GI pipe 40 mm bore, light grade and 15 mm for water with wire mesh funnel all as shown on electrical plate No.03 of SSR Part-I complete including necessary excavation & earth work in any type of soil and PCC(1:3:6) type CI using 20mm graded stone aggregate earth chamber, RCC (1:2:4) type B1 cover slab 40mm thick complete including testing all specified and directed.
Supply and fixing GI strip 32mm X 6mm buried in ground and connected with aluminium strip by means of brazing or fixing it on wall complete all as specified.
Supply & Fixing Aluminium strip 25 mm X 3.15mm complete with saddles and base insulators (made out of porcelain/backalite) and fixing with screws etc, for roof and down conductors complete all as specified. Note:- The strip shall be connected with complete brazing to other strips.
Supply and fixing single pointed air termination aluminium rod 12mm dia and 300mm long and fixing to GI pipe with clamps, nuts, bolts and washers complete all as specified
M&L test point terminal block made of gun metal or phosphorus bronze 75mm x 75mmx 25 mm, drilled and screwed including 3 No. 8 mm dia 25 mm long hex all as specified and directed
Supply and fix rubber mat of size 1 meter x 2 meter x19mm for HT/LT equipment
Servicing of good lift with electrically operated motor 415 volts, 3 phase, AC 50 Hz supply suitable to serve G + 04 upper floors Including gates & Auto Rescue Device with following additional functions & check ups for smooth functioning all as directed (a) LSVF controller suitable for existing stops and simplex full collective operation (b) new reference system in hoist way suitable new LSVF controller including magnets, cams, limit switches (c) New hoist way harness and travelling cables suitable for new LSVF controller and fixtures (d) New COP(SPEC60) type suitable for existing stops with ss hairline finish face plate and collective operation (e) Hall buttons (SPEC60) combined with 7 segment type position indicators and SS hairline face plates suitable for existing stops and simplex full collective operation (f) Voice annunciator in car (g) Battery operated alarm bell (h) Battery operated emergency light (i) Top of car inspection box (j) Pit switch along with auxiliary pit switch (k) Locks for 5 nos of landings (l) Retiring cam with mounting accessories (m) Complete new junction boxes, troughs for car, machine room and host way (n) New RCOB in the machine room suitable for new VF controller (o)New car gate switch and safety operated switch (p) Accordian gates for all landing (q) servicing all internal wiring with electrical fittings,fan & replacementof floor mat required size with colour, LED lights as require to lift (r) servicing of motor /Brakes/reverse & forwarding controls Note;- Replacing parts are included inservicing with the paid amount NOTE :- Included following replacement
Removing old unservicable goods door of any make/size
Removing old unservicable goods door drive of any make/size
Supply and fixing landing doors 2400 X 2400 opening centre opening telescopic door SS stainless steel 304 Hairline Finish
Supply and fixing car doors 2400 X 2400 opening centre opening telescopic door with motor and door operating cams, complete set
Supply and fixing car door motor & operating mechanism Complete with all required accessories for smooth functioning of car door
SAI CONSTRUCTIONS
SHIRDE ENTERPRISES
chowdeshwariconstructionco
HEERA CONSTRUCTION CO.
C R R CONSTRUCTIONS
Moulya Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .