Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.2 L+₹41,006.50 (2.19%)Rejected-Finance PO BANARHAT DIST JALPAIGURI W B PIN 735202 | BANARHAT | JALPAIGURI | WEST BENGAL | 735202 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.4 L+₹66,804.50 (3.56%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.0 L+₹1.2 L (6.56%)Rejected-Finance INDEX NO D 35 ADG NEI GUWAHATI OLD HASIMARA POST HASIMARA DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹20.5 L+₹1.7 L (9.13%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹18.7 L
EMD Value
₹37,400
Closing Date
9 Mar 2024, 6:00 pmClosed
CWE (AF) BAGDOGRA
Commander Works Engineers (AF) Bagdogra Bagdogra Airport (WB) Pin- 734 421 Tele 0353 - 2698308
COMPREHENSIVE REPAIR AND MAINT TO DUCTABLE ACs, MEGA SPLIT ACs AND VRF UNITS AND MISC ALLIED WORKS, AND VARIOUS TYPE OF COOLING APPLIANCES AND REPAIR MAINT TO HT CABLES, VCBs TRANSFORMER AND PROTECTIVE GEAR AT AF STN BAGDOGRA UNDER GE AF BAGDOGRA.
2023_MES_632670_2
8541/BAG/2023-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAGDOGRA
MES Contractor enlisted as Class E category c(i) having deposited Standing Security of Rs 50,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
10 documents required · 10 mandatory
₹500
GE (AF) BAGDOGRA
₹37,400
Yes
4 May 2024
24 Feb 2024
11 Mar 2024
24 Feb 2024
9 Mar 2024
2 Mar 2024
Amount
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender documents & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Dismantling of defective 4.5 to 11.6 TR mega split and ductable spilt unit of any make of following capacity for rough checking/repair of all accessories and components and reassembling the same after repair/ replacement of defective accessories/ components and testing complete all as directed by Engineer-in-Charge including transportation to workshop and back. Note:- (i) Supplying of new accessories/ components required for the system shall be measured & paid separately here-in-after. (ii) Supply of sealed compressor unit, painting etc shall be measured and paid separately. (iii) Old serviceable accessories/components obtained from dismantling shall be refixed as directed by Engineer-in-Charge and labour charges for refixing shall be deemed to be included in the unit item rate.
S&F compressor suitable for following capacity and type of split type AC including taking down unserviceable one complete all as specified and directed. Make:- Blue star/Kirloskar/LG/Carrier Note:- Unserviceable compressor shall be the property of contractor.
4.5 TR reciprocal compressor suitable for 4.5 TR Mega split AC
5 TR reciprocal compressor suitable for ductable type
5.5 TR scroll compressor ductable type
S&F Aluminium fan blade each suitable for outdoor unit of following capacity for split/mega ductable split type AC including taking down unserviceable one:-
4.5 TR (Mega)
5/5.5 TR (ductable)
7.5 TR (ductable)
11.6 TR (ductable)
S&F capacitor of following capacity including taking down unserviceable one:- (Make:- Sarda/Universal/Usha)
S&F 3 pole power contactor of following capacity including taking down unserviceable one:- (Make:-Havells/ Legrand/ Seimens/ L&T)
S&F MCB TPN of following capacity including taking down unserviceable one:- (Make:-Havells/ Legrand/ Seimens/ L&T).
S&F MCCB 3 pole of breaking capacity 25 KA complete all as specified and directed. (Make:-Havells/ Legrand/ Seimens/ L&T).
Thermal release type of Cap 63 Amp
Thermal release type of Cap 100 Amp
S&F MCCB 4 pole of breaking capacity 25 KA complete all as specified and directed (Make:-Havells/ Legrand/ Seimens / L&T)
Thermal release type of Cap 125 Amp
Thermal release type of Cap 160 Amp
Taking out unserviceable each blower motor form existing location of following capacity of Split AC, Window AC, mega split/ductable outdoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. Bearing of existing and size and reassembling the blower motor and fixed complete all as directed by Engr-in-Charge.
4.5 TR (Mega Split type)
5 TR (ductable)
5.5 TR (ductable)
7.5 TR (ductable)
11.6 TR (ductable)
Taking out unserviceable blower motor from existing location of following capacity of Split AC indoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing and reassembling the blower motor and fixed complete all as directed by Engr-in-Charge
4.5 TR (Mega)
5 TR (ductable)
5.5 TR (ductable)
7.5 TR (ductable)
S&F following components suitable existing VRF unit of capacity 10 HP and 12 HP complete all as specified and directed
Cordless controller
Corded controller
Y- joint / Distribution joint
Dismantling unsv remote control assembly and replacing unsv items such as IC, PCB Transformer and magnetic coil suitable for indoor following capacity split type AC and reassembling the same after testing complete all as specified and directed.
4.5 TR (Mega Split Type)
5/5.5 TR (ductable)
7.5 TR (ductable)
11.6 TR (ductable)
M&L for detecting leakage of Air conditioning system rectifying the leakage and testing complete all as specified and directed by Engr -in Charge of following capacity
4.5 TR Mega Split AC
5 TR (ductable)
7.5 TR (ductable)
11.6 TR (ductable)
S&F V-Belt Size ‘A-28’ including taking down unserviceable one complete all as specified and directed. (Make:- Nirlon/ Fenner/ Dunlop)
S&F Copper refrigerant pipe of following size:-
S&F insulation for cooling line complete all as specified and directed.
S&F suction/discharge valve including taking down unserviceable one:-
Supply & filling refrigerant gas R-22 for charging 1.5 TR to 11.6 capacity split mega spilt and ductable spilt type AC complete all as specified and directed.
Supply only suitable refrigerant gas R-410a for charging of 1.5 TR to 11.6 TR capacity mega and ductable split type and VRF type Air conditioner complete all as specified and directed.
Disconnecting the electric connection and tasking out AC of any capacity, conditioner any capacity from wall overhauling and servicing the window type AC by help of Blower gun, Soap water etc, oiling greasing as required and painting the AC including outer cover after work the machine refixing in original position and reconnecting the electric connection and making serviceable and recharging the refrigerant gas, if required. Note:- if required extra refrigerant gas will be measured & paid separately
Window type AC 1.5 TR/2TR.
Split type AC 1.5 TR/2TR
Attending the complaints as directed by the Engineer in Charge for carrying any nature defects complete of Window type AC. Split, Mega spilt Ductable Split AC, Water cooler, Refrigerator and Deep freezer, specified and as directed. Note:- (i) Supplying of new accessories/components required for the system shall be measured & paid separately. (ii) Old serviceable accessories/components obtained from dismasting shall be refixed as directed by Engineer-in-Charge. (iii) Completion of Job will be considered only after complete rectification of detect upto satisfaction of Engineer-in-Charge. (iv) Complaint shall be attended on the same day of obtaining complaints & intimate to JE in charge by evening. (v) Rate for necessary stationary for complaint register & complaint slips shall be deemed or including in quoted rate.
Dismantling of defective Window type AC/Split type Air condition indoor/outdoor unit of any make of following capacity for through checking/repair of all accessories and components and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed by Engr-in-Charge including transportation to workshop and back. Note:- (i) Supplying of new accessories/components required for the system shall be measured & paid separately here-in-after. (ii) Replacement of sealed compressor unit painting etc shall be measured and paid separately. (iii) Old serviceable accessories/components obtained from dismantling shall be refixed as directed by Engineer– in-charge and labour charges for re-fixing shall be deemed to be included in the unit of tem rate.
S&F compressor rotary energy efficient/reciprocal in replacement of old compressor having any No of cuts of same size, capacity and connecting with existing system testing to leakage including recharging of refrigerant gas after installation sealed unit with the split type AC of following capacity commissioning complete all as specified and directed. (Make:- Hitachi/Bluestar/carries/LG). Note:- Unserviceable compressor shall be the property of contractor
Supply & filling refrigerant gas R-22 for charging of 1.5 TR to 11.6 TR capacity split mega split and ductable split type AC complete all as specified and directed.
Supply only suitable refrigerant gas R-410 for charging of 1.5 TR to 11.6 TR capacity mega and ductable split type and VRF type Air Conditioner complete all as specified and directed.
Comprehensive maintenance of 4.5 TR (lndoor unit 01 Nos and unit 01 Nos) (46 WEU))Vertical/Mega split type Air conditioner of following capacity of any make. The job including as under:- (i) Inspection, checking, cleaning with soap water and carbon tetra chlorite to the cooling coil and condenser unit. (ii) Inspection, checking and repair of all electrical components. (iii) Servicing of blower motors by greasing oiling and servicing by cleaning thoroughly air filter. (iv) During the servicing of the unit existing refrigerant (Gas) shall be pump down and to kept safe custody for re-use. Note (a) Above job shall be carried out once in a every Quarter. (b) Unserviceable item involving the above job shall be measured and paid separately
Taking down cable jointing Kit, outdoor termination kit and indoor termination kit complete all as specified and directed.
Taking down danger notice plate of any size and type complete all as specified and directed.
Supply and fix danger notice plate of 1.6 mm mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT pole of 25X20 cm size.
Taking out VCB of any type make after disconnecting all electrical connection from common bus bar and removing nuts and bolts etc and dismantling the same for inspection, finding out minor defects and rectify the same complete with cleaning, servicing, over hauling, calibration etc and setting or relays for tripping accuracy specified and directed by Engr-in-Charge (Make:- Crompton/Areva/Alstom/Schinder/ABB) Note:- Spare parts if required shall be measured and paid separately under relevant item including labour charges.
Supply only set of sleeves for epoxy mould (6 Nos) complete all as specified and as directed by Engineer in Charge Make:- Alstrom/ CG/ABB/Areva/Schinder
Supply only push button switch for trip circuit healthy complete all as specified and as directed by Engineer-in-Charge.
Supply only in repair epoxy resin, cast, single phase current Transformer (CT) 11 KV one set of three having ratio 100-50/5+5A (for both incoming & outgoing) having 15VA burden for metering and class 5P10 protection with air insulated CT chamber with complete wiring suitable for 11 KV VCB complete all as specified and as directed by Engineer in Charge. Make:- Alstrom/CG/ABB/Areva/Schinder
Supply only LED indicators (color red/yellow/blue/white/green) complete all as specified and as directed by Engineer in Charge. Make:- Legrand/Seimens/C&S/HPL
Supply only spring charging motor and gear assembly suitable for 11 KV VCB complete all as specified and as directed by Engineer in Charge Make:- Alstom / CG/ ABB/ Areva/ Schinder.
Calibration and setting of IDMT relay 11 KV of existing VCB over current auxillary, master relay as per site requirement complete all as specified and as directed by Engineer in Charge.
Supply only tripping coil assembly for 11 KV VCB complete all as specified and as directed by Engineer in Charge. Make:- Alstom / CG/ ABB/ Areva/ Schinder
M&L in replacement Earthing complete with galvanized steel earth plate electrode 60 cmx60 cmx6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32x6mm, by means nut bolt, nuts check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) typeB-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg /Sqm)and frame of angle iron 25mm x 25mm x 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plant, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plant No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion.
Taking down GI Strip of any size and type complete all as specified and directed.
Material and labour for earth continuity conductor fixed to walls, buried in ground or drawing through pipe GI strip of size 32x6 mm complete including taking down existing strip complete all as specified and directed.
Cleaning /clearing of vegetation around the installations and disposing off complete all as specified and directed.
Material and Labour for dehydration, filtration and cleaning of transformer oil, both indoor/outdoor/ pole mounted/plinth mounted HT switch gear etc. at different location by suitable dehydration plant testing of oil sample before and after dehydration for each transformer/equipment and results of transformer insulation oil minimum upto 45 KV with 2.5 mm gap, recorded jointly by contractor and complete including all necessary tools, transportation etc all as specified/directed by Engineer – in-Charge. Note:- Oil for toping up/fresh fill shall be measured and paid separately under relevant item.
Taking down old drain valve any size or type complete all as specified and directed.
Material and Labour for gun drain valve screwed both ends with iron wheel head. 40 mm dia complete all as specified and directed.
Taking down old breather complete all as specified and directed.
M&L for breather assembly with silica gel complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination head shrink type join complete with jointing Materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out pipe line etc for repairs laying cables etc and getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removal of excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer –in-charge.
Material and labour for clean dry sand in trenches / ducts for cushioning to cable complete all as specified. Note:- Punned thickness shall be measured)
Supplying and laying unreinforced precast cement concrete cable, class HV type 1 Size 300 mm x 180 mm x 40 mm in trenches for cable protection, embossed with ‘ELECTRIC’ on the top surface complete all as specified and as directed by the Engineer-in-Charge.
Taking down/up XLPE cable HT 3 core 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply laying and testing XLPE insulated, screened PVC based galvanised strip armoured electric power cable (Heavy duty) with aluminium conductor 11000 Volts grade lay in trenches ducts along pole, along Transformer cross sectional area 95 Sqmm 3 Core complete all as specified and directed by Engr-in-Charge.
SHRI SANJAY KUMAR GUPTA
M/S East India Traders
M/S ANNI ENTERPRISE
M/S SARKAR ELECTRIC
SARKAR ENGINEERING CO.
KD SAHA and CO.INDIA
M/S BIJAY KUMAR SHIVA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .