Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance CHANDAMETTA CHHINDWARA MADHYA PRADESH | CHHINDWARA | CHHINDWARA | MADHYA PRADESH | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹9.4 L
EMD Value
₹11,752
Closing Date
14 Nov 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
STAFF OFFICER E and M
OFFICE OF THE AGM WCL PENCH AREA
Shifting of 11kV overhead line of MPPKVVCL at Amalgamated Dhankasa and Jamunia UG Project.
2023_WCL_293226_1
wcl-pe3350-enm-41-2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
DHANKASA UG MINE WCL PENCH AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,752
15 Nov 2023
7 Nov 2023
15 Nov 2023
7 Nov 2023
14 Nov 2023
7 Nov 2023
7 Nov 2023 - 11 Nov 2023
Amount
Shifting of 11kV overhead line of MPPKVVCL at Amalgamated Dhankasa & Jamunia UG Project.
PCC POLE 140 KGS 8 MTRS LONG
STAY SET 16MM COMPLETE
PCC POLE 140 KGS 8 MTRS LONG
11KV CROSS ARM 65x65x6 MM ANGLE TYPE
BACK CLAMPS FOR PCC POLE 50x6 MM MS FLAT
11KV TOP CLAMPS 65x65x6 MM ANGLE TYPE
EARTHING COIL OF 115 TURNS OF 50 MM. DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
AAAC RABBIT CONDUCTOR 0.O5 SQ. INCH (55 SQ. MM AL.EQ.)
JOINTING SLEEVES (ALUMINIUM ) FOR DOG CONDUCTOR
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3 15 MM.(7/10 SWG)
STAY INSULATOR 90x65 MM
BACK FILLING OF POLES WITH BOULDERS
GI WIRE 4.0 MM (8 SWG)
STONE BLOCK/RCC BASE PLATE SIZE 450x450x75MM (2 NO. PER STAY AND 01 NO. FOR POLE) DRG NO. DISOM/EZ/47 & 48
CONCRETING (1:3:6) OF STAY @0.2 CMT. PER STAY (16MM)
RED- OXIDE PAINT
ALUMINUM PAINT
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG)GS 2.5 MM DIA (12 SWG)
DANGER BOARD ENAMELED 11 KV
ALUMINUM BINDING WIRE AND TAPE
PCC POLE 140 KGS 8 MTRS LONG
DC CROSS ARMS 8 (2.4 METER) CENTRE TO CENTRE 100X50 X6 MM CHANNEL
STAY CLAMP A TYPR FOR 300 LBS PCC POLE
11 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR
11 KV STRAIN HARDWARE (T&C TYPE) FITTNGS
BRACING SET FOR 8 FEET(2.45 MTR ) CENTRE DP ANGLE OF 65X 65X 6 MM
BACK CLAMP FOR 140 KG PCC POLE OF 65X 8MM MS FLAT
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3 15 MM.(7/10 SWG)
STAY INSULATOR 90x65 MM
STONE BLOCK/RCC BASE PLATE SIZE 450x450x75MM (2 NO. PER STAY AND 01 NO. FOR POLE) DRG NO. DISOM/EZ/47 & 48
CONCRETING (1:3:6) OF PCC POLE @0.3 CMT. PER POLE
CONCRETING (1:3:6) OF STAY @0.2 CMT. PER STAY (16MM)
EARTHING COIL OF 115 TURNS OF 50 MM. DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
GI WIRE 4.0 MM (8 SWG)
RED- OXIDE PAINT
ALUMINUM PAINT
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG)GS 2.5 MM DIA (12 SWG)
DANGER BOARD ENAMELED 11 KV
M S BOLT WITH NUT 16X200 MM
SUSPENSION CLAMP FOR LT AB CABLE
TENSION CLAMP FOR DEAD END FOR LT A.B CABLE
PIERCING CONNECTOR TYPE-I. 1P/3P (MAIN 16- 50SQMM TAP-OFF 16- 50SQMM
PIERCING CONNECTOR TYPE-II(MAIN 16 -50 SQMM TYPE-OFF 16-50 SQMM)
1100 VOLTS GRADE AB XLPE CABLE 3x50 SQ MM + 1x16 SQ MM + 1x35 SQ MM
POLE MOUNTED DEEP DRAWN METAL LT DISTRIBUTION BOX FOR AB CABLE FOR 1 INCOMING 8 OUTGOING 1 PHASE CIRCUIT
POLE MOUNTED DEEP DRAWN METAL LT DISTRIBUTION BOX FOR AB CABLE FOR 1 INCOMING 4 OUTGOING 3 PHASE CIRCUIT
63 KVA ,BIS CERTIFIED LEVEL - II TRANFORMER
PCC POLE 140 KGS 8 MTRS LONG
DC CROSS ARMS 8 (2.4 METER) CENTRE TO CENTRE 100X50 X6 MM CHANNEL
STAY CLAMP A TYPR FOR 300 LBS PCC POLE
11 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR
11 KV STRAIN HARDWARE (T&C TYPE) FITTNGS
DO MOUNTING CHANNEL
BACK CLAMP FOR 140 KG PCC POLE OF 65X 8MM MS FLAT
DO FUSE UNIT 11KV POLYMER
11KV LA POLYMER TYPE GAPLESS/METAL OXIDE 9KV, 5KA LINE TYPE
TRANSFORMER MOUNTING CHANNEL 100x50x6 MM
TRANSFORMER BELTING SET 50x50x6MM ANGLE WITH TWO CROSS FIXING CHANNEL
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3 15 MM.(7/10 SWG)
STAY INSULATOR 90x65 MM
STONE BLOCK/RCC BASE PLATE SIZE 450x450x75MM (2 NO. PER STAY AND 01 NO. FOR POLE) DRG NO. DISOM/EZ/47 & 48
CONCRETING (1:3:6) OF PCC POLE @0.3 CMT. PER POLE
CONCRETING (1:3:6) OF STAY @0.2 CMT. PER STAY (16MM)
AAAC RABBIT CONDUCTOR 0.O5 SQ. INCH (55 SQ. MM AL.EQ.)
DANGER BOARD ENAMELED 11 KV
HI BI-METALLIC CLAMP FOR DTR
BI METALLIC CLAMPS SUITABLE FOR 12MM DIA STUD
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG)GS 2.5 MM DIA (12 SWG)
RED- OXIDE PAINT
ALUMINUM PAINT
M S BOLT WITH NUT 16X200 MM
LT DISTRIBUTION BOX FOR 63KVA TRANSFORMER (200A ISOLATOR & 6 SP MCCB OF 60A)
XLPE LT 1-CORE ALUMINIUM UNARMOURED 50 SQ MM CABLE
XLPE LT 1-CORE ALUMINIUM UNARMOURED 70 SQ MM CABLE
3 PHASE 4 WIRE 20-80 AMPS ACCURACY CLASS 1 LCD DISPLAY STATIC WHOLE CURRENT METER
DTR 11/0.4KV 25KVA ALUMINIUM
GST as applicable should be quoted in percentage, it will be calculated on total amount of Sl. No. 1.01 to 1.80
RAJ ENGINEERING ASSOCIATE
sheikh sabir
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .