Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.1 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹90.7 L+₹1.3 L (1.44%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 3 | L3₹97.9 L+₹8.5 L (9.52%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 4 | L4₹1.1 Cr+₹24.2 L (27.1%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 5 | Rejected-Technical NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | - | Rejected-Technical Not Eligible bidder being two class below |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
3 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Udhampur
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIRS TO BLDG NO P-05, P-09 AND P-55 (OR MD ACCN) AT 1 FOD UNDER GE (SOUTH) UDHAMPUR
2025_MES_695099_1
CWE/U(S)-77/2024-25
Open Tender
Civil Works
Item Rate
210 days
Udhampur
AS per NIT
6 documents required · 6 mandatory
₹1,000
GE (SOUTH) UDHAMPUR
₹1.8 L
16 Apr 2025
27 Jan 2025
10 Mar 2025
27 Jan 2025
3 Mar 2025
18 Feb 2025
28 Jan 2025 - 12 Feb 2025
Amount
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed.
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for including and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed.
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed.
Reinforced cement concrete M-25 design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.0kg of cement per sq. metre, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
Description all as above but in vertical surfaces like skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm (400X400X10mm) in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes , complete all as specified and as directed.
Glazed coloured ceramic jointfree/rectified tiles 600 mm x 300 mm x 10mm thick on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed.
20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 20 mm thick screed bedding / backing layer in CM 1:3, complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed. Note : Water proofing compound to be measured and paid for separately as supply only.
10mm thick rendering on brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed.
Supply only liquid water proofing compound, complete all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed.
Description all as per item No 20 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Taking down shutters of any descriptions area exceeding 1 square metre and not exceeding 2 square metre each complete, all as specified and directed.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plated, 12mm thresh hold etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed.
Description all as per item No 23 above but frame size 105 x 60mm.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
30mm thick flush shutters, solid core construction, with block board core and plywood face pannels and both face is covered with decorative face veneer with liping/frame to match, complete all as specified and directed.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/09 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item above No 28 but without glazing bar complete all as specified and as directed.
Factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately.
Description all as per item above No 30 but without glazing bar complete all as specified and as directed.
Mild steel framed work such as grills, gratings, etc. With ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Welded steel wire fabric mesh weight not exceeding 4 Kgs per sqm fixed to wood or steel members complete all as specified and directed.
Continuous (piano) hinges width of flaps 30 mm when opened, mild steel, bright finish or electrogalvanised complete all as specified and as directed.
18/19mm thick Block boards, grade 2 quality, exterior grade, decorative type with decorative face veneer on both faces, fixed with screw or Steel frame/Timber frame incl teak wood lipping,6mm thick fixed with Nail, complete all as specified and as directed.
Hasp and staple, 100 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, complete all as specified and directed.
40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and as directed.
Ball catches with 8mm dia steel balls and brass body and striking plate including letting in and fixed complete all as specified and as directed.
300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate, fixed to frame, complete all as specified and as directed.
Door eye, Round/Square, triangle, antique Gold R-309, complete all as specified and as directed (ISI Mark).
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:4, complete all as specified.
Machine cut kota stone 18-20mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for laying wall tiles, complete all as specified and as directed.
150mm wide strip of makrana white marble 18-20 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 20 mm thick CM 1:4 mortar backing for fixing the stone slab, complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed.
Description all as per item No 45 above but except brick.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as directed.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed.
Cement concrete tiles 30cm x 30cm x 20mm thick, with mixture of white & grey cement in equal proportion & pigment , machine pressed set, jointed and pointed in neat cement slurry in floors, and cut and polished over roof treatment complete all as specified and as directed.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed.
250 mm long aluminium alloy, anodised, sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
Mild steel cold rolled butt hinges medium weight 100 mm long fixed to steel /angle iron frame by welding, if required complete all as specified.
150mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed.
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
100 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
25mm dia Harrison rails, stainless steel with fixing brackets, stops, rollers etc. alongwith holding for brackets & end caps fixed in repairs, complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, 140mm overall length of cover plate complete all as specified and directed. (ISI Mark)
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed.
Factory Made Solid PVC Moulded Door Shutter wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with wood free EPS, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating fixed in repairs, complete, all as specified and as directed.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zink chrome primer, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint , complete all as specified and as directed.
Preparation of newly plastered or unplastered surfaces of wall & applying two coats of cement base paint over a coat of chalk whitening, complete all as specified and as directed.
Complete removal of existing treatment and applying two coats of cement based paint over a coat of chalk whitening, old decorated or undecorated wall surface, complete all as specified and as directed.
Preparation of new plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper white tinted with roller application over a coat of chalk whitening primer over 3mm thick wall care putty, complete all as specified & directed.
Complete removal of existing treatment, preparation of old plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper white tinted with roller application over a coat of chalk whitening primer over 3mm thick wall care putty, complete all as specified & directed.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling, complete all as specified and as directed.
Preparation old surfaces plastered or unplastered and applying one coat of white wash on ceiling, complete all as specified and as directed.
Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed. Make - Cera (CP No 2071, Jaquar Cat No CNS-WHT-0P01 or equivalent).
Vitreous China wash down water closet pan and seat cover (pedestal pattern), coloured (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed. Make - Cera -S1050101/02, Jaquar Cat No CNS-WHT-WH-10 or equivalent).
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repairs, complete all as specified and as directed. MAKE: Cera Model Combiflush twin flush as per Cat Part No. 2603 or equivalent in performance of makes as specified in PS.
Supply only flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern, complete all as specified and as directed.
Health faucet brass CP with 8mm dia 1.00 meter long flexible tube with wall hook with NRV (Back flow preventor) complete all as specified and as directed. Make : Jaquar Cat part No ALD - 579/573, Cera-F8030103 or equivalent.
Stainless steel grating doom 100mm dia square or round fixed in repairs, complete all as specified and as directed.
Stainless steel soap dish , fixed in repairs, complete all as specified and as directed.
CP tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs fixed in repairs, complete all as specified and as directed. Make : Jaquar Cat Part No CAN-CHR-1111NM/ Cera Cat Part No B2210106/ Prayag/ Kohler/ MARC/ HR Johnson/Parryware or equivalent.
PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and as directed.
Steel peg set colour coated of six as per sample fixed in repairs complete all as specified.
Sinks made of stainless steel with draining board, made out of 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar including fixing cantilever brackets connecting union to pipe and 32mm dia GI pipe duly painted upto Nihani Trap or Floor trap complete as directed at site, overall size 915mmx460mm bowl size 410mm x 330mm x160mm, in repair complete all as specified.
Stainless steel plate rack of size 780mm x 910 x 250mm (31"x36"x10) with separators and 3 tier shelves, provisioning of hook 9 Nos made out of stainless steel sheet of grade AI SI-304 and fixed in repairs, complete all as specified and as directed. Cat No P-348 of Prayag or equivalent.
Dismantling of cast iron or reinforced concrete drain pipes, upto 100 mm internal dia jointed in cement mortar and taking out of trenches or fixed to wall, if required complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 100mm bore, complete all as specified and as directed.
Fixing only Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 100mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 75mm bore, complete all as specified and as directed.
Fixing only Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 75mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 50mm bore, complete all as specified and as directed.
Fixing only cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 50mm bore, complete all as specified and as directed.
Salt-glazed stoneware gully traps, size 150 x 150 mm, square or round mouthed, type 'P', including setting and jointing to drains with cement mortar 1:1, including demolition of old unserviceable gully traps complete all as specified and as directed. (ISI Marks).
100mm cast iron sanitary connections short connections pipe of length upto 300 mm, complete all as specified and as directed.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 75mm bore pipe, fixed in repairs all as specified and as directed.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, fixed in repairs all as specified and as directed.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark)
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75mm bore, fitted with oval access door, fixed in repairs complete all as specified and as directed.
50mm Cast iron cowl, fixed in repairs complete all as specified and as directed.
Cast iron Reducer 100mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed.
Cast iron Reducer 75mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes/soil pipes (any size, type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., for (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed.
110 mm bore PVC SWR bends and fixed with joint sealent etc complete all specified and as directed.
110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and as directed.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 50 mm bore pipe, complete all as specified and as directed.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore pipe, complete all as specified and as directed.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore pipe, complete all as specified and as directed.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as in sunken floor/ foundatiom, complete all as specified and as directed.
Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and as directed.
Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and as directed.
RCC 1:1.5:3 (nominal mix), using 20 mm graded crushed stone aggregate as in chajjas, complete all as specified and as directed.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in and getting out in any type of soil, complete all as specified and as directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified.
Reinforced concrete pipes 150mm bore ,class NP3, laid and jointed complete with coller all as specified and as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed.
Pre-cast RCC cement concrete 1:2:4 type B-1 (20mm graded) as in manhole cover slab and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed.
Taking down 15mm Bore steel tubing and connections including all fittings and removing to store, complete all as specified and as directed.
Taking down 20mm Bore steel tubing and connections including all fittings and removing to store, complete all as specified and as directed.
15 mm bore steel water tubing medium grade galvanised with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and as directed.
Description all as per item No 128 above but except GI steel tubing.
20 mm bore steel water tubing medium grade galvanised with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and as directed.
Description all as per item No 130 above but except GI steel tubing.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm, fixed in repairs, complete all as specified and as directed.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm, fixed in repairs, complete all as specified and as directed.
Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm with adjustable flanges, fixed in repair, complete all as specified and as directed. Make : Jaquar Cat Part No - CON-053KN, CERA QTF 2006201 or equivalent
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as directed. Make : Jaquar Cat Part No -SOL-06169B, CERA QTF 2006461 or equivalent
Bib taps , long body, fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repairs, complete all as specified and as directed. Make : Jaquar Cat Part No - CON-037KN, CERA QTF 2006152 or equivalent.
Shower roses 15 mm brass chromium plated with or without swivel joints, any size, including 125 mm long arm and fixing to steel pipe or union, complete all as specified and as directed. Make : Jaquar Cat Part No - OHS-1719, CERA F-7040101 for arm, F-7040101 for shower rose or equivalent.
Brass chromium plated wall mixer with bend (provision for overhead shower), complete with 115mm long bend pipe and wall flange all as per Cat Part No - 7375 of Prayag/CERA/Jaquar or equivalent.
S&F for sink mixer with regular swining spout wall mounted with connecting legs & wall flanges, complete all as specified and as directed by Engr-in-Charge.Make : Cat Part No - 7355 of Prayag/Jaquar Cat Part No ARI-39309/ Cera or equivalent.
Rotational moulded polyethylene water storage tank, (white colour) three layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed.
Point wiring for one light/ fan/bell/Exhaust point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unsheathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.4mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per Item No. 142 But for one light point control by two nos two way switches with other Independent Board with two run of 1.5 sqmm PVC insulated unsheathed FRLS copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed FRLS copper conductor single core cable (green color) as earth lead or & as directed by Engg- in- charge to match with the existing specification complete all as specified .
All as per srl item No. 142 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly.
All as per srl item No. 142 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly.
All as per Srl item No 142 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly.
Modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed
Modular switch 6 Amps single pole two way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed.
Modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed.
Modular Bell push flush type 6 amp 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed.
Modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed.
Modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Blockcomplete all as specified and directed.
Calling Bell ding dong 230 volts single pole 50Hz complete all as specified and directed.
S&F in replacement VTPN MCCB DB Double Door (Including 125 Amp MCCB) 16 kA(as Incommer) 4 way double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F in replacement sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, complete all as specified and as directed. (Note: MCBs will be measurd separately).
S&F in replacement Industrial metal clad socket outlet with single pole enclosure with 2 pin and earth plug socket including 1No. MCB SP 20A 10kA complete all as specified and as directed .
MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repairs, complete all as specified and as directed.
MCB SPN, 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x10sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 161 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Modular electronic step type fan regulator 120 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and directed.
Taking down Ceiling fans, cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge.Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
Supply and fixing Emergency LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light , which gets automatically switched ON during power cut and run effectively upto 3 Hours ,Lumens Capacity-2000lm, pf- 0.90(min) ,Colour temperature 6500K, CRI > 80, IP 20 connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply and fixing Emergency LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp which gets automatically switched ON during power cut and run effectively upto 3 Hours, Lumen Capacity-1000lm, pf- 0.95(min) ,Colour temperature 6500K, CRI > 80, IP 20 including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 4 core including taking up/down old unserviceable cables. complete all as specified and as directed.
Double Walled corrugated DWC Pipe of size 40 mm including snap fit coupler Pt-II for protection of LT Cable in underground all as specified.
GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, complete all as specified and as directed.
Batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.
Supply and fixing Emergency LED lamp 9 watt, Lumen Capcity 900lm , Pf>0.9, Colour Temp-6500K, CRI>80, Protection Class-IP20,Base Type- B-22D/E27.
Taking down Exhaust fans, cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed. Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the exhaust fans functional. No extra payments will be done on this account.
Taking down Geyser, cleaning its dust particles,One coat of synthetic enamel white spray painting (Only If Steel Body Geyser found) ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to etc complete all as specified and as directed. Note :- (i) The additional GI Item of Medium Grade of Size 15/20 mm (Tee/Elbow/Union/Bend/Nipple/Socket/Short Length) nuts & bolts, and fastner etc if found defective/damage deemed to be replaced and make the Geyser functional. No extra payments will be done on this account.
Taking down existing prepaid meter & Display unit alongwith conduit pipe dia 25mm qty approx 09 RM, casing caping pipe size 20mm qty approx 2 RM & 6 core control cable (RJ-11) qty approx 11 RM from each qtr and refixing the same back to its original position including connecting the 6 core control cable (RJ-11) from prepaid meter to display unit complete all as specified and as directed.
Supply and fix Exhaust fan, steel body AC single phase 230/240 V of size 300mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty, complete all as specified and as directed.
M/S ASHOK KUMAR PACHIALA (BID ID -3249398)
jyoti parkash sharma (BID ID -3254047)
RAMAN CONSTRUCTION CO (BID ID -3253160)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .