Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.8 L+₹2.2 L (6.50%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹38.2 L+₹4.6 L (13.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹38.8 L+₹5.2 L (15.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹42.0 L+₹8.4 L (25.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
SPL REPAIR TO BLDG NO PS 37 QUARTER GUARD) AND PROVN OF TOILET BATHROOM BLOCK AT TRIKUTA OFFICER INSTITUTE AT NAGROTA MIL STN
2024_MES_667926_1
CA NO GEN-33/2024-2025
Open Tender
Civil Works
Item Rate
180 days
NAGROTA
Class D category a ii
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹94,800
Yes
29 Oct 2024
25 Jul 2024
14 Sept 2024
25 Jul 2024
12 Sept 2024
1 Aug 2024
Amount
SCHEDULE ‘A’ PART-I ( LIST OF B/R WORKS AT NAGROTA) Demolition of brick work of stone / boulder mosonry laid dry.complete all as specified and directed by Engineer-in-Charge.
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified.
Taking down cement plaster on brick or stone walls, etc .including raking out joints, hacking for key, scrubing down with water etc .complete all as spd and directed.
M & L 15mm thick rendering on brick work or concrete surface in cm 1:4 to be fair and even with out using extra cement complete all as spd and directed.
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement all as specified.
M & L preparing new plastered surfaces of walls and applying Finishing of wall with acrylic smooth exterior paint of required paint of required shade new work (two or more coat applied @ 1.67ltr/10Sqm and including priming coat of exterior primer applied @ 2.2 Kg/10 Sqm). complete all as spd and directed.
M&L for Preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 to 2 mm thick wall care putty over a coat of primer on walls etc all as specified .
M&L for 10mm thick cement plaster in CM 1:4 on celling/parapets and finished surface even and smooth without using extra cement
M&L rendering 5 mm thick on internal surfaces of ceiling in cement mortar 1:6 finished even & smooth without using extra cement as specified and directed.
M&L for Preparation of newly plastered surfaces of ceiling and applying two coat of white washing, all as specified complete all as specified.
M&L for Preparing newly plastered surfaces of walls and applying three coats of white wash.complete all as spd and directed.
M & L preparing new plastered surfaces of walls and applying two coats of cement base paint. complete all as spd and directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash.complete all as spd and directed.
M L for removal of existing treatment and preparation of old plastered surfaces of walls, & applying two coats of oil bound distemper over one coat of wall care putty of 1 to 2 mm thick and one coat of primer complete all as specified.
M & L preparing & Complete removal Old plastered surfaces of walls and applying Finishing of wall with acrylic smooth exterior paint of required paint of required shade new work (two or more coat applied @ 1.67ltr/10Sqm and including priming coat of exterior primer applied @ 2.2 Kg/10 Sqm). complete all as spd and directed.
M & L for preparation of old surface , Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, oil, greasy spots & rubbing with sand paper and and applying one coat of white wash on ceiling.
Taking down chowkats or frames with shutter (with out taking off shutter from the frame) exc 1.5 sqm & n. exe 4 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
Taking down chowkats or frames with shutter (with out taking off shutter from the frame) n exc 1.5 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
S & F pressed steel frames made of size 1.25mm thick MS steel for door with one or more rebates incl lugs, hold fast, lock strike plate etc complete of size 125 x 60mm including one coat of red oxide primer and PCC 1:3:6 as in back fill to chowkats all as spfd. Make:- Shivam Steel, Jammu
M&L 35 mm thick 2nd class hard wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), complete all as speciied.
S & F Box type Steel windows side hung double shutters (inside for wiremesh & out side for glass), incl guard10mm square bar ,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS complete all as shown on drawing No- CEUZ/TD/1302/09 sheet No- 1/3 to 3/3 directed by Engr-in-Charge.
S & F Box type Steel ventilator Top hung double shutters (inside for wiremesh & out side for glass), incl guard10mm square bar ,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS complete all as shown on drawing No- CEUZ/TD/1302/09 sheet No- 1/3 to 3/3 directed by Engr-in-Charge.
S&F mild steel wire cloth. 0.46mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples
S&F butt hinges of mild steel cold rolled medium weight of size 100mm as specified.
S&F Aluminium anodised, barrel tower bolts size 200 mm of extruded section and fixed complete all as specified.
S&F Aluminium handles, cast type, anodised Size-150mm, anodised section and fixed complete all as specified.
S&F 3 mm thick sheet glass ordinary quality glazing with steel pins,oil putty to steel windows and, beads nails etc to wooden surfaces as in square exc 0.50 sqm in each pane,complete all as specified.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane. complete all as specified.
M & L for PCC 1:2:4 type B-1 as in benching coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills etc.
Demolition of cement concrete (unreinforced) ground floor to 3rd floors and pavings n exc 15 cm thickness (below or above ground level ) and removing unserviceable material exc 100 mtr as specified.
M&L for75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays finished even and smooth without using extra cement complete all as specified.
M&L for 25mm thick PCC type BO 1:2:4 (12.5mm graded aggregate in flooring finishing rough to recieveing Top layer for flooring complete all as specified and directed.
S&F vitrified ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified.
M&L for screed bed or bedding layer of cement mortar 15mm thick in CM 1:6 for laying floor finish complete all as specified.
S&F vitrified ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, on vertical surface such as skritting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 10 mm thick rendering in CM (1:4) complete all as specfied and directed complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises as directed
Machine cut kota stone flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) over 25mm thick PCC (1:2:4) type B1 over 15mm thick screed bed in CM ( 1:4) as in floor finished rough and applying a coat of cement slurry @ 03 Kg/Sqm of surface complete all as pecified and directed.
Machine cut kota stone slab 18-20mm thick in skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado.complete all as directed.
S&F in repair Soild PVC door frame of size 50 mm x 47mm made out of 5 mm plain coloured PVC sheet, reinforced with MS square tube supplying and fixing in opening as per specification and drawing. complete all as directed.
S & fix in reairs Factory made solid panel PVC door shutter 30 mm thick ( style ) consisting of frame work made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour P.V.C‘ C’ channel having a PVC sheet strip 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail on either side and as gap inserts for top rail; and bottom rail paneling of plain, colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rail with suitable PVC sheets beading and jointed together with solvent cement in frame at site as per specification. complete all as directed.
S&F Curtain rod 25mm dia aluminum brass polished with ends bulbs rings of required size including bracket complete all as directed.
Taking up or down steel tubing for 15mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified.
Taking up or down steel tubing for 20mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge
M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and dirceted.
S&F in repair angle valve with wall flange , cast copper alloy, chromium plated fency type screwed for 15 mm iron pipe, complete all as specified.
S&F in repair CP Bib taps,long body, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified.
Vitreous china squatting pan “ORISSA” pattern size 580x440mm ( Make : Hindware)white with integral foot rests all as fixed in repairs including cast iron ‘P’ or ‘S’ trap 100mm bore including PVC low level cistern of 10 litres capacity including brackets jointing to flush pipe, PVC connection (450x15mm), flushing pipe complete fixed in repair all as directed by Engr-in-Charge.
S&F for 110mm bore Cast Iron (SWR) 'P' or 'S' trap, including fixed with solvent cement complete all as specified and directed.
S&F in repair flush Cistern with Drainage L-Bend Pipe with Gasket & Installation Kit (Suitable for EWC), complete all as specified.
S&F in repair 450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers (Both Side) Without Nipple (Suitable for Geysers) complete all as specified.
S&F vitreous china wash basin white of size 550x400mm incl waste coupling bracket and PVC waste pipe incl taking down old and as specified and as directed.
Dismantling unservicable /cracked water tanks and removing from site capacity exe 250 ltr n.exe 500 ltr complete all as specified and dirceted.
S&F for 500 ltrs capcity Rotational moulded polythene water storage tanks (cylindered vertical closed top ) hoisted and fixed in position all as spd in SSR Part –I, complete all as specified and dirceted.
Removing old brick tiles/ RCC Padding including Mud phuska and removing from site and clean the surface of roof, with cleaning with water and remove dust complete all as specified.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thickness each with wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between the two layers finished even and smoothes in roof padding all as specified and as directed Note:- The wire mesh shall be measured and paid separately under the respective item below.
Supply only 25 mm size, wire netting of galvanized iron chicken mesh, 0.71 mm dia complete all as specified and directed.
Material and labour APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified laid over a coat of bituminous primer @ 0.40 ltr /Sqm & finished with applying bitumen grade 85/25 coat @ 1.2 Kg /Sqm. APP membrane shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction all as directed and finished with applying one coat of aluminium paint as directed by Engineer-in-Charge
Chequered cement concrete coloured tiles 30 cm x 30 cm x 25 mm thick set , jointed and pointed in neat cement slurry with grey cement and pigment in floors complete all as specifed
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 complete all as specifed
M&L for PCC (1:3:6) 75 mm thick Type C-2, using 40mm graded stone aggregate as in floors in bed to recive tiles /path tiles etc. complete all as specifed
M&L for Cement concrete tiles 25 cm x 25cm x20mm thick machine pressed with grey cement and no pigment set jointed and pointed in neat cement slurry on roof over APP membrane laid over 15mm thick cement screed bed in cement mortar 1:6
M&L for Applying one coat of aluminium paint on top of APP membrane complete all as specifed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specifed
Excavation for post holes (or in similar hole ) each n.exc 0.50 Cum including dismantling PCC including disposal of surplus n.exc 50m all as specifed and directed by Engineer -in- Charge.
M&L for PCC 1:3:6 type C-2 (20mm graded aggts) in foundation filling and mass concrete all as specified and directed
M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed etc complete all as specifed
Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete.
Supply only Chain link fencing with or without line wires,any type and mesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing all as specifed and directed.( rails, staining bolts will be measured in seperate Item)
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 5 to 10mm dia of shank complete all as specified and directed
S&F, TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified.
S&F mild steel conforming to Fe-290 Gde E-165 in Hand rails,haif round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars,for doors,balusters,nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, Angle iron post and struts in fencing including cutting tops to shape as directed, drilling hole, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coat of synthetic enamel paint on steel surfaces over a coat of red oxide all as specified and directed by Engr-in-Charge
Dismantling of Barbed wire in fencing of any description all as specifed
S & F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc.,(each line wire to be measured separatley) complete all as specified. as directed.
Taking down and refixing of angle iron gate ( 3mtr to 5 mtr wide and 2 mtr to 2.5 mtr high) including embedding of pintel hinges in concrete blocks and fixing locking arrangement, complete all as specified and as directed by the Engr-in-Charge.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Soft/ loose soil.complete all as spd and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils.complete all as spd and directed.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.complete all as spd and directed.
M/L Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete.complete all as spd and directed.
M & L For Broken brick bat hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.complete all as spd and directed.
M&L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing.complete all as spd and directed.
M&L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in foundation, plinth beams,footings etc,.
M&L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in columns.
M&L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in floor or roof beams complete all as spd and directed.
M&L for Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like.complete all as spd and directed.
M&L for Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick.complete all as spd and directed.
M&L for Use and waste of formwork for sides of columns for rough finished surfaces.complete all as spd and directed.
M&L for Use and waste of formwork for foundation beams floor beam roof beam etc as in lintel over 1.5m clear span. for rough finished surfaces complete all as spd and directed.
M&L for Use and waste of formwork to sides and soffits of floor or roof beam, beam hauchings, girder, bressum-mers, lintels, cantilivers, shelves incl supports, overhangs, etc. Also splay between floors and beams, etc. for rough finished surfaces complete all as spd and directed.
M & L TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with chips complete all as spd and directed.
M&L for Mild steel TMT bars 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, beams,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.complete all as spd and directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders complete all as spd and directed.
M&L for non skid cereamic coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11 sqm but n. exc.0.18 sqm, in floor etc set and joined in neat cement slurry and pointed in white or .coloured cement to match including 15 mm thick in cement mortar 1:6 screed bed or bedding layer of mortar for laying floor finishes as directed
M & L glazed, ceramic, coloured tiles of size450x350x7mm thick, on vertical surfaces such as skirting, dados etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles including endering 10 mm thick in cement mortar (1:3) as in bedding layer for laying of tiles in vertical surfaces complete all as specified & directed.as specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as spd and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges.complete all as spd and directed.
S & F 150mm size extruded aluminium handle cast type anodised all as specified and as directed by Engineer-In-Charge.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes, single socketed in any length with rubber ring joints laid in floors or trenches, etc including necessary excavation & earth work whenever required complete as specified.
S & F 110mm bore PVC (SWR) Soil, waste and vent pipes, single socketed in any length with rubber ring joints laid in floors or trenches, etc including necessary excavation & earth work whenever required complete all as spd and directed.
S & F 110 mm bore PVC (SWR) bends any radius.complete all as spd and directed.
S & F 75 mm bore PVC (SWR) bends any radius.complete all as spd and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 110 mm bore pipe complete all as spd and directed.
S & F PVC connection pipe 15mm size with PTMT nuts of 600 length including fixed.complete all as spd and directed.
S&F PVC (SWR) 100mm dia floor trap, plain with grating including jointing with solvent cement.complete all as spd and directed.
M&L For extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form moulds mitred/stopped ends etc.complete all as spd and directed.
Surface excavation n.exc 30cm deep and avg 15 cm deep and getting out any type of soil.complete all as spd and directed.
M&L Hard core of gauze n.exc 63mm deposited spreaded and leveled in layers n.exc 15cm thick, watered and rolled/rammed to a true surface.complete all as spd and directed.
S&F 15 mm size Angle cock, cast copper alloy (fancy type), chromium plated, screwed for iron pipe or for brass ferrule all as directed.
S&F PTMT single towel Rail of size 600 mm long as specified and directed.
S&F stainless steel soap dish holder including fixing arrangement complete all as specified and directed.
S&F 150mm dia Reinforced concrete pipes ,class NP-2 laid and jointed complete all as spd and directed
M & L 150 mm thick cement concrete 1:4:8 type D-2 in bed to drain pipes incls packing under, and haunching against the sides of pipes after they are laid and tested of bore 150mm to 300mmdia drain pipe complete all as spd and directed.
S&F of 125 mm dia Fancy type Chromiun plated shower rose shower rose type fixed to 15mm dia pipe complete all as specified and directed.
Supply and fixing Vitreous China Urinal, full stall type, white with PTMT waste fitting, PVC waste pipe, brass CP urinal spreader including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete all as specified and directed.
SCHEDULE ‘A’ PART-II ( LIST OF E/M WORKS AT NAGROTA) Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custedy for taking credit complete all as specified and directed
Taking down ceiling fan/Exhaust fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed
M&L for Concealed Point wiring using FRLS PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor earth wire drawn in and including PVC conduit medium grade ISI marked not less than 20 mm dia concealed in wall & surface on ceiling with all conduit fittings etc terminated in and incl concealed pressed steel sunken box readily available ( having wall thickness not less than 1.22 mm upto 200 x 300 mm box size & having wall thickness not less than 1.63 mm beyond 200 x 300 mm ) duly covered with 3 mm thick bakelite sheet cover for fixing switches , sockets , fan regulators etc incl testing and making good to disturbed surface to match existing surface for one light/fan/bell point complete all as specified and directed.
All as per Srl item No.119 above but for one socket out let 5Amp controlled by one switch on same board with other switch . compete all as specified and directed
All as per Srl item No 119 above for one socket out let 5 Amp controlled by one switch on independent board with other switch . compete all as specified and directed
M&L for Concealed Point wiring using FRLS PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 2.5 sqmm including 2.5 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor earth wire drawnIN and including PVC conduit medium grade ISI marked not less than 20 mm dia concealed in wall & surface on ceiling with all conduit fittings etc terminated in and incl concealed pressed steel sunken box readily available ( having wall thickness not less than 1.22 mm upto 200 x 300 mm box size & having wall thickness not less than 1.63 mm beyond 200 x 300 mm ) duly covered with 3 mm thick bakelite sheet cover for fixing switches , sockets , fan regulators etc incl testing and making good to disturbed surface to match existing surface for 15 Amps Socket complete all as specified and directed.
S&F switch piano flush type 5 Amps single pole one way compete all as specified and directed
S&F Socket outlet 5 Pin 5 Amps Single flush type compete all as specified and directed
S&F switch socket combination 2 in 1, 5 pin, 5 Amp flush type compete all as specified and directed
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type compete all as specified and directed
S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed.
M&L for Concealed Point wiring using FRLSH PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including ERS Steel Conduit conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories terminated in and incl concealed pressed steel sunken box readily available ( having wall thickness not less than 1.22 mm upto 200 x 300 mm box size & having wall thickness not less than 1.63 mm beyond 200 x 300 mm ) duly covered with 3 mm thick bakelite sheet cover for fixing switches , sockets , fan regulators etc incl testing and making good to disturbed surface to match existing surface for one light/fan/bell point complete all as specified and directed
Supply and fixing LED light fitting 1X16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed.
Supply and fixing ceiling fan 1200 mm sweep single phase AC 230/240V complete incl grouting of eyebolt of suitable size in ceiling and fixing the fan by mean of suitable bolts, nuts, washers and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan complete all as specified and directed
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcomplete all as specified and directed
S&F SPN 6 Way (Enclosuer Size 300x300x190mm) FLP Lighting Distribution Panel Incoming :- MCB, 2P, 32Amp - 01 Nos Outgoing :- MCB , 1P, 6 Amp- 04 Nos with complete internal Bus Bar & Wiring up to terminals. complete all as specified and directed
Supply and fixing LED lights fitting 1x 20 W, 220V, AC including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings including 9 Watt LED bulb complete all as specified and directed.
Supply & fixing heavy duty Metal body Exhaust fan 300 mm sweep single phase AC 230/240V complete complete all as specified and directed with louvers. complete all as spd and directed.
S&F sheet metal enclosure distribution board SPN 08 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete all as specified and directed incl taking out existing UNSV DB with MCBs.complete all as spd and directed.
S&F sheet metal enclosure distribution board SPN 4 way 230 V, 50 Hz Single door with neutral and din rail complete all as specified and directed.
S&F MCB SPN 40 A to 63 A 10 KA 240 volts "C" series complete all as specified and directed
S&F MCB single pole 6 to 32 Amps 10 KA 240 volts "C" series complete complete all as specified and directed
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link Vertical TPN 4 way suitable for MCCBas incomer, 63 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar including 63 A MCCB as incomer 16 KA complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site incl taking out of exsing UNSV DB with MCBs.complete all as specified and directed(Note: MCCB 63 Amp 4 pole should be measured and paid seperately)
S&F MCCB 63A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers of Ventil Air-DB of Havells or equivalent in approved make complete all as specified and directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and directed by Engr-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections complete all as specified and directed
M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking down existing UNSV complete all as specified and directed
S&F building security light luminaries energy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including MS Bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and suitable size nuts, bolts and washers etc including taking down of existing light fitting and complete ,all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 25 Sqmm 4 core, complete all as specified and directed by Engineer-in-Charge
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables complete all as specified and directed
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick excavated earth complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
M&L for well burned bricks , laid flat ( old size) sub class B designation '75' for cable protection copmplete all as specifed and directed.
Sand cushioning to under ground cable laid in trenches for laying of LT UG cables 8 cm depth before laying the cable and 15 cm after laying and punned down to a depth of 10 cm as per MES SSR Part-I (2020) complete all as specified and directed. Note: Punned thickness shall be measured and paid to the contractor.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
M&L for Earthing complete with galvanised mild steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground prefarably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25x4 mm by means of bolts, nuts, check and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75 mm, XPM reinforced not less than 1.60 Kg/Sqm with suitable built in handle made from 12 mm dia MS round bar, excavation and earth in any type of soil., 20 mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5 m length, charcoal, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Supply and fixing in repair of aluminium strip 25 x 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground, complete all as specified and directed.
S &F Air termination, sigle pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by Engr-in-Charge.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex, head scew complete all as specified and directed by Engr-in-Charge.
U K Engineering Works (BID ID -3094406)
M/S Shankardass Devidass (BID ID -3085669)
R.K. Works (BID ID -3083550)
M/S CJ CONSTRUCTIONS (BID ID -3087867)
M/S VINAY KUMAR SHARMA (BID ID -3085505)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .