Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.2 LAccepted-AOC 1 215 BHOOSA MANDI FATEHGARH FATEHGARH FARRUKHABAD UTTAR PRADESH 209601 | FARRUKHABAD | UTTAR PRADESH | 209601 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹22.8 L+₹1.1 L (4.84%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹23.6 L+₹1.9 L (8.74%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹26.9 L+₹5.2 L (23.8%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹27.5 L+₹5.7 L (26.4%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | 5 | Rejected-Finance Not being lowest |
Tender Value
₹29.8 L
EMD Value
₹59,600
Closing Date
28 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112 Taj Road Agra Cantt
SPL REPAIR TO BLDG NO. P-126 AND P-127 AT FATEHGARH CANTT
2021_MES_478780_1
86088/E8
Open Tender
Civil Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted in Class D category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹59,600
Yes
26 Nov 2021
30 Sept 2021
3 Nov 2021
30 Sept 2021
28 Oct 2021
14 Oct 2021
30 Sept 2021 - 7 Oct 2021
60 days
Amount
Demolition of cement Concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 square metre each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm not exceeding 4 square metre each complete all as specified and directed.
S & F Pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including cutting holes in brick work for hold fast and making good by PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) etc complete all as specified and directed
S& F for 35mm thick, factory made, 2nd class hardwood, Plain framed, panelled shutter (two panel)(single/Double leaf) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M & L for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for top rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S & F for Soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm palin colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.
M & L for Cutting chases, pinning in, making good to facings of brick work masonry where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
S & F factory made steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed.
S & F factory made steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded etc complete all as specified and directed.
S&F in repair factory mader steel ventilators with top hung shutter incl hinges steel peg stay complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples,complete all as specified and directed.
S&F Mild steel sliding door bolts of size 250mm, bolt type, stove enamelled black, with bright bolt not less than 12mm dia and fixed, complete all as specified and directed.
S&F Aluminium handle 125 mm long cast type anodised, complete all as specified and directed.
S&F Aluminium anodized barrel tower bolt 150 mm long of extruded section complete all as specified and directed.
S&F Mild steel pressed handles 125mm size, oval type, stove enamelled black, complete all as specified and directed.
S&F Mild steel barrel tower bolts 150mm long, stove enamelled black,with barrel of extruded section and fixed in doors/windows complete all as specified and directed.
S&F Butt hinges 100 mm long medium weight cold rolled Mild Steel complete all as specified and directed
S&F Sheet glass, ordinary quality 3.00 mm thick not exceeding 0.5 sq m in each pane (in single/double /triple storey bldgs), in steel/wooden window with cleat/oil putty as per site requirement complete all as specified and directed
All as per item No.19 above but fixing as in repair,(in single/double /triple storey bldgs), in steel/wooden window with cleat/oil putty as per site requirement complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed.
M&L of brick work with sub class 'B' burnt bricks old size straight or curved on plan exc. 6 m mean radius bult in CM 1:6 complete all as specified and directed
M&L for preparation of new or previously untreated surface of steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Dismantling floor, hearth or wall tiling of any description, any position including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for Glazed ceramic coloured tiles of size 450 x 350 x 7 mm thick in vertical surface, set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile over and including 10 mm thick screed in CM (1:3) on fair faces of wall surface finished even and rough without using extra cement, shade & design as approved by AGE (I) complete all as specified and directed.
M&L for non skid ceramic any coloured/printed tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by AGE(I),set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,over and including 15 mm thick screed bed in cement mortar (1:4) in floors complete all as specified and directed.
Supply and fixing in repairs vitreous China squatting pan of pattern(Orrissa pattern) of size 580mm x 440 mm white with PVC 'P' Trap of 110/125mm bore as suitable at site, front or back inlet and in built foot rests any pattern fixed to flushing pipe and anti syphonage pipe and making good floor including lime concrete bedding etc complete all as specified and directed.
S & F in repair for Vitreous China, semi-pedestal pattern (Anglo-Indian Type) water closet coloured including 'P' or 'S' trap with PVC flush pipe 32 mm dia for low level flushing cistern incl plastic seat cover white closed pattern with flat bottom and cover and jet connection and mild steel chrominum plated or aluminized hanging device complete all as specified and directed.
S & F in repair Vitreous China bowl urinal flat back of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal in wall with cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, PVC flush pipe of required dia & length, grating and Union for discharge pipe . (Exclusive of fixing flush pipe to flushing cistern, trap and waste pipe) etc complete all as specified and directed.
S&F in repair Low Level Flushing Cistern PVC valveless syphonic action type, 10 ltrs capacity white, with inlet pipe connection PVC, ball float of 20 mm bore and handle including brackets of MS angle iron of size 25 x 25 x 5 mm & minimum 200 mm long and flush pipes required dia and length to squatt pattern closet including all joints and making good to the wall etc complete all as specified and directed. complete all as specified and directed.
S&F PVC connection pipe 15mm size & length 450 mm with PTMT nuts of length 450mm etc complete all as specified and directed.
S & F in repair three layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity, hoisted and fixed in position, including 20 mm dia PTMT Float valve complete all as specified in SSR Part I complete all as specified and directed.
Demolition of existing sunken treatment upto height of 90 cm including plaster and M&L for water proofing treatment on existing sunken floor/wall with and including the following specification complete all as specified and directed :- (a) 50mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) and laying in slope towards spout pipe. (b) 15mm thick (average) plaster in CM 1:3 on sunken floors and walls using WPC as per manufacturer instruction (c) Apply one coat bituminous primer @ 0.5 Kg/ Sqm on walls and floor conforming to IS 3384-1965 on prepared surface till the surface is properly impregnated (d) Apply hot air blown bitumen 85/25 grade @ 1.2 Kgs/Sqm confirming to IS 702-1988 (e) APP polymeric water proofing memberance weight not less than 3.0 Kgs/Sqm laid as per manufacturer instructions confirming to IS (f) One spout of 40mm GI pipe length 0.45 M in sunken floor (g) Filling of sunken floor with PCC 1:5:10 type E-2 (using 40 mm graded stone aggregate) upto height not exc. 0.5 m as per site requirement. (h) S&F of trap as per site requirement
Taking up or down 15 mm dia steel tubing and connections complete all as specified and directed.
All as per item No.34 above but of 20mm bore.
S&F steel water tubes medium grade bore of tube 15mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed.
All as per item No.36 above but of size of 20mm bore
S & F in repair 15 mm bore Bib tap standard of PTMT fancy type long body any colour high pressure screwed for iron pipe and fixed. (Minimum weight for 15mm-90gms) complete all as specified and directed.
S & F in repair 15 mm Stop valve of PTMT any colour high pressure screwed with long shank and cup(concealed type), (Minimum weight 15mm-110gms) for iron pipe and fixed etc complete all as specified and directed.
S & F in repair 15 mm bore Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) etc complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves 20 mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed
S & F in repair Cast iron soil, waste and vent pipes of 100mm bore in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S & F in repair Cast iron soil, waste and vent pipes of 100mm bore in any length with or without ears, with cement joints,fixed to wall etc complete all as specified and directed.
S & F in repair cast iron floor trap of 100mm, with grating including jointing to waste pipe with cement joint fixed in cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S & F in repair cast iron Nahani trap 100mm, with grating including jointing to waste pipe with cement joint fixed in cement concrete type B-1 (1:2:4) (using 20 mm graded stone aggregate) complete all as specified and directed.
S & F for CI branch pieces 100mm, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fixed with run lead joint complete all as specified and directed.
S & F for CI single 'Y' junctions 100mm fixed with run lead joint complete all as specified and directed.
S & F for Cast iron bends (any redius) of 100mm bore with oval access door fixed with run lead joints complete all as specified and directed.
S & F for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia complete all as specified and directed.
S & F in repair Salt-glazed stoneware gully traps type 'S', square or round mouthed size 150 x 150 mm complete all as specified and directed.
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material to out side MD land complete all as specified and directed.
M & L 15 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed.
M & L for 15 mm thick rendering in CM (1:4) on other than fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed.
M & L for 5 mm thick rendering in CM (1:3) on fair faces of brick work / concrete surface of ceilling to be finished even and fair without using extra cement complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of white cement primer complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement primer complete all as specified and as directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceilling complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls by rubbing down and making surface smooth and applying two coats of OBD complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls by rubbing down and making surface smooth and applying two coats of cement base paint complete all as specified and directed.
M&L for Preparation of old external surfaces of walls, Facias, cornices etc and applying one coat of Anti Fungal Weather Coat Exterior Emulsion paint (Apex - Ultima) on walls all as per manufacturer instruction complete all as specified and directed.
M & L for preparation of old plastered surfaces of ceiling by rubbing down and making surface smooth and applying two coats of white wash complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Taking down aluminium sub main wiring and making good disturbed surfaces to match with the existing surface of roof / wall / floor complete all as specified and directed.
Material and labour for point wiring for one light point / holder / exhaust fan or one fan or bell point controlled by one switch with using 1.5 Sqmm (nominal area) multistranded copper conductor, single core, PVC (FRLS) insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size 20 mm dia bore or as directed by EIC with using new sunken type pressed steel box / terminal boxes for mounting fittings/junction boxes not less than 1.6mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick bakelite laminated sheet, and including all accessories and using 1.5 Sqmm (nominal area) multistranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete for one light point 5/6 Amp complete all as specified and directed.
All as per Srl item No 65 here in above but point wiring for 5 pin switch socket combination point, 5/6 Amps on independent board controlled by one switch.complete all as specified and directed.
All as per Srl item No 65 here in above but point wiring for 5 pin switch socket outlet, 5 Amps on same board with other switches complete all as specified and directed.
All as per Srl item No 65 here in above but point wiring for one six pin switch socket combination indepdent, 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) PVC (FRLS) insulated and unsheathed copper conductor single core multistranded 1100 volts cable and earth complete all as specified and directed. Notes for item 65 to item 68 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
Supplying & fixing for piano switch flush type, 5/6 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
Fixing only piano switch flush type, 5/6 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed. Note :- Old serviceable switch retrieved from item No. 63 shall be re-used in the work
Supplying & fixing for switch socket combination 2 in 1, 5 pin and 5 Amp flush type complete all as specified and directed.
Supply and fixing for switch socket combination 2 in 1, 5 pin, 5 Amp and 15 Amp flush type complete all as specified and directed.
Supplying & fixing for lamp holder PVC / Polycarbonate type, insulated body with back plate suitable for batten fitting complete all as specified & directed.
Supply and fixing LED lamp of 9W and colour temperature 6500 K suitable to fix in angle holder complete all as specified & directed.
Supply and fixing rotory 5 stepped type electronic fan regulator 100 watt 230 volts complete all as specified & directed.
S&F ceiling rose PVC / polycarbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. Notes :- (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs)
Supply and fixing in repair of VTPN DB suitable for mounting MCCB as incomer of rating 63 Amp vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall complete electrical connection with aluminum thimbles as required complete all as specified and directed. Make- C&S Cat part No.CSDBTPNVDD04S, Legrand Cat part No. 507730 & Indo Asian Cat part No.811870
Supply and fixing in repair MCB distribution board SPN 240 volt, 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed. Cat part No.5076 11 of make Legrand or equivalent model in specified makes as approved by AGE(I).
Supply and fixing in repair MCCB 63 Amp, 25 KA, 4 pole Thermal magnetic trip unit including complete electrical connection by appropriate size of copper lugs complete all as specified and directed.
Supply and fixing in repair of MCB SPN 16-40 Amp 240 volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing in repair MCB SP 6 to 32 Amp 240 volts 'C' curve 10 KA complete all as specified and directed.
S&F in repair of surface mounted LED 15W luminaire with a dimension of 312 x 312 mm complete all as specified and directed. Make - Philips Cat part No.SM200CLED15S4000PSU OD WH & equivalent model in C&S / Havell's / Bajaj as approved by AGE (I).
S&F LED 20 watt LED extruded aluminium battan fitting batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of > 120 lumens / W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.9, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed. Philips Cat Part No.BN02IC LED20S PSU CW GR S2 / Havells Cat No.ENDURALINEARNEOBS20WLED865SPCWH / Wipro Cat Part No.LL20-281-XXX-65AL1 & Bajaj Cat part No.BJCEB 118/120 W2EB 1X18/20W FTL.
S&F in renewal LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 10W (2 feet 10 W) luminaire lumen > 1000 lm, system efficiency of > 120 lumens / W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 buring hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra lower voltage safe level <60 V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed. Make- Philips Cat No.BN021 LED 10S-6500 PSU GR S1, Wipro Cat No.LL20-111-XXX-65NE3 & C&S Cat part No.LTTB2F10WLED/W
M&L in repair for earthing complete with galvanized earth plate electrode of size 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire of 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 (20 mm graded stone aggregate) as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 (20 mm graded stone aggregate) reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M/S DEEN ENTERPRISES
Shree Gopal Engineers & Contractor
M/S shree traders
deva engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .