Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003.
MMNPPNA_23_24_166 (i)Construction of B.Ed college approac Road to Lichutola Ward No.1, (ii) Construction of Road from Residence of Mrigen Das house to Bijoy Shah house, Ward No. 1,(iii) Improvement of Road from Rajib Bhavan to Bageswari Mondir Link R
2023_PWD_32885_73
CE/DEV/TB/08/2023-24/16
Open Tender
Civil Works
Item Rate
270 days
Bongaigaon MB
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,840
₹4.8 L
Yes
O/o the Chief Engineer Roads, PWRD, Assam,
30 May 2024
12 Oct 2023
27 Oct 2023
12 Oct 2023
27 Oct 2023
20 Oct 2023
12 Oct 2023 - 19 Oct 2023
19 Oct 2023
Amount
Construction of B.Ed college approach Road to Lichutola Ward No.1 : Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (I) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401. II) For Grading II Material
Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means-
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 In 1:4 cement mortar
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (ii) Sandy material
Drain Work : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (ii) Ordinary rock (not requiring blasting)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (B) With natural Grave l(i)P.C.C Grade M 10
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (B) With natural Grave l(iii)P.C.C Grade M 120
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204In (i) 1:5 cement mortar
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
RCC Covered Drain : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (In ordinary soil, Depth up to 3.00m)
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (N) without plasticiser, (E) RCC M20, (a) Height upto 5.0m, Case I : Using concrete mixer
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Construction of Road from Residence of Mrigen Das to Bijoy Shah, Ward No. 1 : Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (I) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401. II) For Grading II Material
Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means-
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
RCC Drain : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (In ordinary soil, Depth up to 3.00m)
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (N) without plasticiser, (E) RCC M20, (a) Height upto 5.0m, Case I : Using concrete mixer
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and ravelling as per technical specification Clause 1906.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
Semi - Dense Bituminous Concrete: Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5% of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.508. complete in all respect. including carriage of mixed materials up to 10.0 Km initial lead from mixing plant ) (Including cost of testing of materials at site and laboratory as directed by the deptt.) 'With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H specification) for Grading II (10 mm nominal size)
Hump type speed breaker: Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
Hump type speed breaker : 'Semi - Dense Bituminous Concrete: Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5% of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.508. complete in all respect. including carriage of mixed materials up to 10.0 Km initial lead from mixing plant ) (Including cost of testing of materials at site and laboratory as directed by the deptt.) 'With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H specification) for Grading II (10 mm nominal size)SDBC
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Painting of speed breaker : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 800mm x 600mm rectangular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600mm equilateral triangle
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Construction of RCC Drain from Dilip Paul's house to hotel Kanishka Raod : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil, A Mechnical Means
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Construction of RCC Drain from Himanjan Choudhury's House to Sulaj Dorji's House : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil, A Mechnical Means
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Construction of RCC Drain from Sulata Dorji's house to entrance of Bagheswari Hill : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil A Mechnical Means
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Improvement of Road From Bajwi Hotel to Dwijendra Narayan Ray house Road : Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 800mm x 600mm rectangular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (i) 600mm equilateral triangle
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
RCC Drain : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (In ordinary soil, Depth up to 3.00m)
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (N) without plasticiser, (E) RCC M20, (a) Height upto 5.0m, Case I : Using concrete mixer
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Improvement of Road from SH-2 to D.C. Office Road : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (In ordinary soil, Depth up to 3.00m)
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (N) without plasticiser, (E) RCC M20, (a) Height upto 5.0m, Case I : Using concrete mixer
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
Semi - Dense Bituminous Concrete: Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5% of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.508. complete in all respect. including carriage of mixed materials up to 10.0 Km initial lead from mixing plant ) (Including cost of testing of materials at site and laboratory as directed by the deptt.) 'With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H specification) for Grading II (10 mm nominal size)
Construction of RCC Slab Culvert on MG road from N. Das residance to Abdul Rezzaq residance : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil A Mechnical Means
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, A. With crushed stone., P.C.C grade M 10
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, P.C.C grade M 15
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, P.C.C. grade M 20
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (i) Sand filling
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Construction of RCC Slab Culvert on Narendra Poddar residance to B.N.Das residance road : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil A Mechnical Means
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, A. With crushed stone., P.C.C grade M 10
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, P.C.C grade M 15
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, P.C.C. grade M 20
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (i) Sand filling
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Construction of Road from Assam Still Godown to Ray Medical Road : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil A Mechnical Means
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Construction of Back side drain from Tripthi hotel to Ray Medical : Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shoring and bracing removal of stumps and other deleterious mater, dressing of sides and bottom and back filling with approved material as per MORTH Clause No. 304. i. In Ordinary Soil A Mechnical Means
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.(N) Without plasticiser, (C) RCC Grade M20, Case I : - Using concrete Mixer
Plain / Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttring form work as per clause 802,804,805,806,807,1202 and1204 A. with crushed stone (B) With natural gravel (IV) RCC M-25 Grade (i) Height upto 5.0m
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205. (with crushed stone, RCC Gr M20, For nominal mix 1:2:4, Height upto 5.0m)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (with sandy material)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Construction of N.S.Road from Lakhan Thakur residance to Maharaja Hotel Culvert : Earth work in excavation for foundation of structure upto 3.00 m depth as per drawing and Technical Specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of side slopes and bottom and backfilling with approved material
Type A (Concrete Cradle) Bedding Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 PCC grade M10 Nominal Mix 1:3:6.
Providing and laying RCC pipe(NP3) for culvert on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection work, backfilling, concrete and masonry work in head wall and parapets Clause 1106 1000mm dia
Brick masonry work in cement mortar in foundation of head walls complete excluding pointing and plastering as per drawing and technical specification Clause 1109 (ii) in prop.1:4
Plastering with cement mortar 1:4, 15 mm thick on brick work in sub-structure as per Technical specification Clause 613.3
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (i) Granular material
Protection ( Boulder Apron bed protection)
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Sri Bhupen Nath
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .