Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.5 LQualified Make: AQUADET RO
Model: AQUADET(500LPH) TAPTI NAGAR JABALPUR MADHYA PRADESH 482004 | JABALPUR | MADHYA PRADESH | 482004 | Make: AQUADET RO
Model: AQUADET(500LPH) | L1 | Qualified MSE | |
| 2 | L2₹1.6 L+₹17,000 (11.5%)Qualified Make: Aemric
Model: AEM 500 LPH 31 SECTOR 10 AMBALA HARYANA 134003 | AMBALA | HARYANA | 134003 | Make: Aemric
Model: AEM 500 LPH | L2 | Qualified MSE, Category: General | |
| 3 | L3₹2.9 L+₹1.4 L (95.9%)Qualified Make: unicare
Model: Unicare_500LPH Reverse Osmosis Water Purifier 121 GOLDEN PLAZA TAGORE ROAD RAJKOT RAJKOT GUJARAT 360002 | RAJKOT | GUJARAT | 360002 | Make: unicare
Model: Unicare_500LPH Reverse Osmosis Water Purifier | L3 | Qualified MSE, Category: General | |
| 4 | Disqualified Make: Aemric
Model: AEM 500 LPH E BLOCK RANCHI | Make: Aemric
Model: AEM 500 LPH | - | Disqualified MSE | |
| 5 | Disqualified Make: bluebird
Model: IRO500 1ST FLOOR GURUNANAK COMPLEX NEAR CHOWALAL HINDI HIGH SCHOOL G T ROAD ASANSOL BARDHAMAN ASANSOL DURGAPUR POLICE COMMISSIONERATE | Make: bluebird
Model: IRO500 | - | Disqualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
₹6,500
Closing Date
30 Aug 2018, 10:00 amClosed
Potable water purification system Average Turn Over of Last 3 Years 12 Lakh (s) Experience with Gov. Required 3 Year (s) Potable Water Purification System ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier
Gravity operated water purifier
Water Purifier electro- deionization Based Ultraviolet (UV) LAMP No Yes
No Ultra Voilet (UV) Lamp power consumption 30 * STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection * Number of float valves/sensors 2 1-5 INPUT PARAMETERS Input Water TDS 2000 1000
2000
3000
4000
5000 OUTPUT PARAMETERS Recovery at 27 25-35 25-35
30-40
90-100
1/4 degree Centigrade 70-80
50-60 Output Water of RO system Conforming to Indian Standard IS 10500(latest) * Output water capacity (Litre/Hour): 500 10
25
50
100
250
500
750 Arsenic and Floride removal capability false true
false Misc
warranty etc Thin-film composite membrane Yes Yes
No
NA High Pressure Pump Yes * Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes
No Pre Filter Vessels: Yes Yes
No Micron Filter Yes Yes
No Membrane Housing Yes Yes
NA Auto cut Yes Yes
No No of candles (Nos) 1 1-5 Installation Type Floor mounted Table top
Wall mounted
Floor mounted
Floor mounted & enclosed Warranty period ( for free replacement of machine 2 2
3
1 (or higher) Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2
1 (or higher) Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm No Yes
NA Chloride & Flouride removal facility No Yes with Pump
Yes without pump
No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - * Test certificate No and date: - * Name and Address of laboratory which - * 2/4 conducted Test: * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Yogesh Kumar 560007
2 ASC Training Centre Agram Post
Bangalore-56007 Near Trinty Circel 1 15
498859
GEM/2018/B/70608
Potable water purification system
15 days
Karnataka; Bengaluru Urban
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Average Turn Over of Last 3 Years 12 Lakh (s) Experience with Gov. Required 3 Year (s) Potable Water Purification System ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier | - | - | - |
| Gravity operated water purifier | - | - | - |
| Water Purifier electro- deionization Based Ultraviolet (UV) LAMP No Yes | - | - | - |
| No Ultra Voilet (UV) Lamp power consumption 30 * STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection * Number of float valves/sensors 2 1-5 INPUT PARAMETERS Input Water TDS 2000 1000 | - | - | - |
| 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 5000 OUTPUT PARAMETERS Recovery at 27 25-35 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 1/4 degree Centigrade 70-80 | - | - | - |
| 50-60 Output Water of RO system Conforming to Indian Standard IS 10500(latest) * Output water capacity (Litre/Hour): 500 10 | - | - | - |
| 25 | - | - | - |
| 50 | - | - | - |
| 100 | - | - | - |
| 250 | - | - | - |
| 500 | - | - | - |
| 750 Arsenic and Floride removal capability false true | - | - | - |
| false Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes Yes | - | - | - |
| No | - | - | - |
| NA High Pressure Pump Yes * Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes | - | - | - |
| No Pre Filter Vessels: Yes Yes | - | - | - |
| No Micron Filter Yes Yes | - | - | - |
| No Membrane Housing Yes Yes | - | - | - |
| NA Auto cut Yes Yes | - | - | - |
| No No of candles (Nos) 1 1-5 Installation Type Floor mounted Table top | - | - | - |
| Wall mounted | - | - | - |
| Floor mounted | - | - | - |
| Floor mounted & enclosed Warranty period ( for free replacement of machine 2 2 | - | - | - |
| 3 | - | - | - |
| 1 (or higher) Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2 | - | - | - |
| 1 (or higher) Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm No Yes | - | - | - |
| NA Chloride & Flouride removal facility No Yes with Pump | - | - | - |
| Yes without pump | - | - | - |
| No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - * Test certificate No and date: - * Name and Address of laboratory which - * 2/4 conducted Test: * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Yogesh Kumar 560007 | - | - | - |
| 2 ASC Training Centre Agram Post | - | - | - |
| Bangalore-56007 Near Trinty Circel 1 15 | - | - | - |
₹6,500
30 Aug 2018
20 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_498859.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .