Assistant Engineer,PWD,SSKM(H)Sub- Division.
244 AJC Bose Road, Kolkata-700020
IPGMER-SSKM Hospital-Emergent repair work of Recovery (Surgery Male) at 2nd floor at BIN (OLD building) at IPGMER SSKM hospital during the year 2026-27.
2026_WBPWD_5016551_9
WBPWD/AE/SSKMHSD/NIT-06e/26-27
Open Tender
CIVIL WORKS
Percentage
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,744
Yes
6 Oct 2026
9 Jul 2026
22 Jul 2026
13 Jul 2026
20 Jul 2026
13 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge | 28.06 | Sqm | 90 | ₹2,525.4 |
| 2 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as permanufacturers specification. (0.4 Kg / m² of concrete surface. | 28.06 | Sqm | 309 | ₹8,670.54 |
| 3 | Stripping off worn out plaster and raking out oints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. | 21.4 | Sqm | 19 | ₹406.6 |
| 4 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributingthe same and with proper scarping and cleaning the reinforcement anddisturbed concrete with wire brush etc. after applying a coat of cementincluding the cost of wire netting I.R.C or X. P. M. & cost of all handling andscaffolding complete as per direction of Engineer-in -charge.
25 mm thick. | 28.06 | Sqm | 516.16 | ₹14,483.45 |
| 5 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar
20 mm thick plaster | 21.4 | Sqm | 171.73 | ₹3,675.02 |
| 5.01 | With 1:4 cement mortar.
10 mm thick plaster | 28.06 | Sqm | 130.55 | ₹3,663.23 |
| 6 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification andas per direction of the EIC. (In Ground Floor)
One Coat.
Solvent based interior grade Acrylic Primer. | 21.4 | %Sqm | 3,370 | ₹72,118 |
| 7 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :
(Two coats)
Luxury Quality | 21.4 | Sqm | 70 | ₹1,498 |
| 8 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.
False Ceiling (with 4mm thick Pearl Designer Fibre Cement Board and E-GridT-2430/1510). | 28.06 | Sqm | 705 | ₹19,782.3 |
| 9 | Supplying & laying of approved make and brand of scratch proof, flexible & homogeneous P.V.C. Vinyle flooringconforming to IS:3462 - 1982 in required finish, fixed withsynthetic acrylic adhesive after preparing the floor, levelling &smothaning when necessary with suitable putty, as per thedesign & instruction of the Engineer-in-charge.
2 mm thick (Plain) | 28.06 | Sqm | 510 | ₹14,310.6 |
stage.html
html • 0.06 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Tendernotice_2.pdf
PDF • 1.88 MB
BOQ_5086140.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .