| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC PUNE | PUNE | MAHARASHTRA | 410301 | L1 | Accepted-AOC Lowest 1 Bidder | |
| 2 | L2₹14.0 L+₹2.8 L (24.4%)Rejected-AOC PUNE | PUNE | MAHARASHTRA | 410301 | L2 | Rejected-AOC Not the Lowest 1 Bidder | |
| 3 | L3₹17.1 L+₹5.9 L (51.9%)Rejected-AOC 181 SECTOR 3 RADHA PURAM ESTATE MATHURA GANESHRA ROAD MATHURA UTTAR PRADESH 281001 INDIA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-AOC Not the Lowest 1 Bidder | |
| 4 | Rejected-Technical 124 1 SADGURUNAGAR BHOSARI ASHTAVINAYAK COLANY PUNE NASHIK ROAD PUNE MAHARASHTRA 411039 MH26B0008505 27AAIFP3585H1ZV R M MII STATUS AS VERIFIED | PUNE | MAHARASHTRA | 411039 | - | Rejected-Technical Not Meeting PQ criteria as per NIT |
Tender Value
₹14.2 L
EMD Value
₹28,475
Closing Date
20 Dec 2022, 3:00 pmClosed
Executive Engineer
Electrical Section CSIR NCL Pune 411008
Providing APFC panel in Sub-Station-I at CSIR- NCL
2022_CSIR_137212_1
Elect / APFC Panel/22-23/05
Open Tender
Electrical Works
Item Rate
60 days
CSIR NCL Pune
Please Refer Tender Documents
3 documents required · 3 mandatory
₹500
DIRECTOR
₹28,475
11 Jan 2023
6 Dec 2022
21 Dec 2022
6 Dec 2022
20 Dec 2022
6 Dec 2022
6 Dec 2022 - 20 Dec 2022
Amount
SITC of APFC PANEL of 500KVAR For 750KVA x 2 Nos (1500KVA) Transformers. Fabrication,painting,supply, installation, wiring, testing and commissioning at NCL 415 volt 3 phase, 50 Hz ,500 KVAR Capacitor Bank and Automatic switching Power Factor Control Panel comprising of 2 No.x 100 KVAR , 4 No.x 50 KVAR, 2 No.x25 KVAR, 3 No.x 10 KVAR , 4 No.x5 KVAR, capacitor units in Bank formation. (with 100 kVAr spare capacity in panel for future upgrade) capacitors to be switched by capacitor duty contactor tested as per IEC 60947-4-1 for AC-6b duty. Before Quoting Please check the detailed specifications of 500KVAR APFC Panel Page Nos: 33 to 35 And Refer Drawing No.APFC PANEL/01 Page No 39 in Technical Bid Volume II for more details.
SITC of APFC PANEL of 200KVAR For 1 Nos x750KVA Transformer. Fabrication,painting,supply, installation, wiring, testing and commissioning at NCL operated at 415 volt 3 phase, 50 Hz ,200 KVAR Capacitor Bank and Automatic switching Power Factor Control Panel comprising of 2 No.x 50 KVAR, 2 No.x25 KVAR, 3 No.x 10 KVAR , 4 No.x5 KVAR, capacitor units in Bank formation. (with 100 kVAr spare capacity in panel for future upgrade) capacitors to be switched by capacitor duty contactor tested as per IEC 60947-4-1 for AC-6b duty. Before Quoting Please check the detailed specifications of 200KVAR APFC Panel Page Nos:36 to 38 And Refer Drawing No.APFC PANEL/02 page No.40 in Technical Bid Volume II for more details.
Supplying, erecting & terminating XLPE armoured cable 3½core 400 sq. mm. aluminium conductor XLPE insulated,1100 V grade with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses or laid in provided trench/ pipe as per Site Engineers instructions for 200KVAR APFC Panel. Rate includes :- 1)Laying of 3 1/2 c x 400 Sq.mm. cable & Terminations 2)Supplying and fixing suitable size of M.S. clamp made from 25mmx5mm M.S. flat with suitable size of Anchor fastners.
Termination of 3 1/ 2 core,400 Sq.mm.Al. cond., XLPE insulated,1100 V grade, armoured cable with suitable size of aluminum Crimping type lugs, suitable size of cable gland . (Each termination will measured separately) For 500KVAR APFC Panel
jvs engineering
KUMAR ELECTRICAL AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .