Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.2 LAccepted-AOC 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | L-1 | Accepted-AOC Being L-1 Bidder. | |
| 2 | L-2₹5.6 L+₹1.4 L (32.3%)Rejected-Finance GUT NO 256 PLOT NO 62 GAJANAN NAGAR CHIKALTHANA AURANGABAD GAJANAN NAGAR CHIKALTHANA AURANGABAD MAHARASHTRA 431007 | AURANGABAD | MAHARASHTRA | 431007 | L-2 | Rejected-Finance Not being L-1. | |
| 3 | L-3₹6.3 L+₹2.1 L (48.7%)Rejected-Finance | L-3 | Rejected-Finance Not being L-1. | |
| 4 | L-4₹7.2 L+₹3.0 L (70.4%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-4 | Rejected-Finance Not being L-1. | |
| 5 | Rejected-Technical FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | - | Rejected-Technical Not eligible as per e-NIT criteria. |
Tender Value
₹6.6 L
Closing Date
30 Mar 2021, 3:00 pmClosed
AGM(EE), DBAI Airport, Nagpur
O/o AGM(EE), Engg. Block, DBAI Airport, Nagpur
ARMO of E and M Installations at Jalgaon Airport SH- Bi-Annual CMC of Cassette Type - Split Type Air Conditioners, Water Coolers and Water Purifiers Year 2021-23
2021_AAI_73607_1
AAI/NGP/E-E/JAL/20-21/NIT-05
Open Tender
Electrical Works
Item Rate
730 days
Jalgaon Airport
Please refer e-NIT.
16 documents required · 16 mandatory
₹1,180
Yes
Exempted
12 May 2021
19 Mar 2021
31 Mar 2021
19 Mar 2021
30 Mar 2021
19 Mar 2021
19 Mar 2021 - 26 Mar 2021
Amount
Bi-annual comprehensive maintenance of cassette type air conditioners of all makes of following capacity at different locations including providing & fixing all necessary consumables and spares including replacing faulty compressor for the period of two years etc. complete as required as per conditions and specifications.
4 TR cassette type air conditioners (1st Year)
4 TR cassette type air conditioners (2nd Year)
3 TR cassette type air conditioners (1st Year)
3 TR cassette type air conditioners (2nd Year)
Bi-annual comprehensive maintenance of split type air conditioners of all makes of following capacity at different locations including providing & fixing all necessary consumables and spares including replacing faulty compressor for the period of two years etc. complete as required as per conditions and specifications.
1.5 / 2.0 TR spilt type air conditioners (1st Year)
1.5 / 2.0 TR spilt type air conditioners (2nd Year)
Bi-annual comprehensive maintenance of water coolers of all makes with following capacity at different locations, including providing & fixing all necessary consumables and spares including replacing of faulty compressor for the period of two years etc. complete as required as per conditions and specifications.
40/80 Ltrs. (1st Year)
40/80 Ltrs. (2nd Year)
60/120 Ltrs (1st Year)
60/120 Ltrs (2nd Year)
Bi-annual comprehensive maintenance of RO type water purifiers of following capacity of all makes at different locations including replacement of all type of filter cartridges & RO membranes (from OEM / Authorized Dealer of OEM), booster pump, etc. including consumables and spares for the period of two years etc. complete as required as per conditions and specifications.
Aquaguard model 10 LPH (1st Year)
Aquaguard model 10 LPH (2nd Year)
Nasaka Model - S50 Super - 50 LPH (1st year)
Nasaka Model - S50 Super - 50 LPH (2nd year)
Bi-annual Comprehensive Maintenance of the following capacity water cooler cum purifier including replacement of compressor, filters & RO membranes (from OEM / Authorized Dealer of OEM), PCB, pumps/motors, U.V.Lamp etc. as per breakdown / preventive maintenance requirement for the period of two years etc. including consumables and spares for the period of two years etc. complete as required as per conditions and specifications.
Blue Star 80 Ltr capacity (1st Year)
Blue Star 80 Ltr capacity (2nd Year)
Trans-installation, testing & commissioning of 1.5/2 TR split air conditioner by dismantling, shifting & fixing indoor unit on wall/ceiling/structure and outdoor unit on wall/stand including providing & fixing suitable size duly painted / powder coated M.S. / G.I. equal angle base frame (ODU Stand), fixing existing suction/discharge refrigerant copper piping with new elastomeric nitrile rubber insulation, re-laying existing control cabling from indoor to outdoor unit, fasteners, charging of refrigerant gas i/c minor civil works and all accessories etc. complete as per technical specifications as required.
Supply & fixing (Additional or Extra to Item No: 6) of suction & discharge refrigerant copper piping for 1.5/2 TR split AC with elastomeric nitrile rubber insulation between indoor and outdoor units with suitable size of clamp / MS hanger / MS support / MS angle as per site requirement and as per technical specifications as required.
Supply & fixing 25 mm dia. UPVC drain pipe including cutting, jointing with approved solvent cement compound as per IS 14735, etc complete as required.
Supply and laying of 3 C x 4 Sq. mm PVC insulated, FRLS PVC sheathed, unarmoured, multi stranded copper cable as per IS : 694 along with refrigerant piping between indoor and outdoor unit of 1.5/2.0 TR Split type AC units etc as required.
Opal HVAC Services
MULTISERVE COOLING SOLUTIONS
Manish Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .