| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-Finance 19 RAMESH NAGAR LALIT APARTMENT JAI BHAVANI MATA ROAD VILLAGE TOWN AMBOLI VILLAGE CITY ANDHERI WEST MUMBAI | L1 | Accepted-Finance single tender accepted by competent authority |
Tender Value
Refer Docs
EMD Value
₹34,828
Closing Date
30 Apr 2022, 5:45 pmClosed
The Executive Engineer E BSNL ED Mumbai
The Executive Engineer E BSNL Electrical Division 5th Floor A Wing BSNL Admin Bldg Juhu Tara Road Santacruz West Mumbai 400054
Rate Contract for maintenance of Window AC Split AC units at various TE Bldgs BTS sites under Kalyan SSA
2022_BSNL_110852_1
NIT NO 22/EEE/BSNL/ED/MI/2021-22
Open Tender
Electrical Works
Item Rate
364 days
Mumbai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO (F and A) BSNL
₹34,828
21 May 2022
23 Mar 2022
2 May 2022
23 Mar 2022
30 Apr 2022
23 Mar 2022
Amount
Attending complaint and checking of faults of AC unit including controller, power supply D.B. by skilled technician, rectification of minor faults/wiring etc. as reqd . ( Note :- The item shall be measured from subdivision HQ ( i.e Kalyan ) for one side distance only )
NOTE: This item shall be measured for verification of initial defect of each AC unit. For subsequent visit to attend the AC unit to provide the items here under will not be paid separately. It is assumed that all the items as below shall be carried out by agency in first visit only. Any subsequent visit required shall be borne by the agency.
Upto 50 kms
Above 50 to 100 kms
Above 100 kms
Carrying out Wet Servicing of 1.5TR/2TR window/Split AC/High Sensible unit i/c removing, cleaning all components and filters, dedusting by high pressure air blower/ Jet pump for washing condenser, evaporator if required), refixing, tightening electrical connections, testing of AC unit, recording all parameters in service report etc as reqd. Item also includes visit charge for carrying out wet servicing.
Attending of leakage in 1.5 TR Split AC/Window AC unit by brazing / flaring the leak points, vacumising, purging flushing the system, and making the system leak proof i/c arranging brazing kit and supplying & charging of R22/ R410 / R134 refrigerant gas at site, testing & commissioning etc as required
Dismantling of 1.5 /2.0 TR Window/Split /High Sensible Split AC Indoor & Outdoor unit a/w stand, piping, cable on MS tray / Wall, removing existing DB, MCBs, Timers, (Pump down of refrigerant) & other associated items of AC job etc.and cleaning of indoor & out door units, keeping all dismantled material at suitable place ready for shifting as required.
Shifting/Transportation of 1.5 / 2.0 TR Window/Split/High Sensible AC units with all accessories from various exchanges of SSA and shifting to TE Bldg ( as per LOI). i/c hiring of vehicle, loading of ACs and unloading at TE etc. complete as required.
Upto 2 nos AC units upto 20 KM
More than 2 nos AC units upto 20 KM
Upto 2 nos AC units From 21 KM to 50 KM
More than 2 nos AC units From 21 KM to 50 KM
Upto 2 nos AC units s From 51 KM to 100 KM
More than 2 nos AC units From 51 KM to 100 KM
Replacement of following by new components of 1.5TR / 2TR Window / Split AC units suitable for operation on 1ph 230V AC supply i/c connections, testing etc. i/c credit (disposing of the dismantalled as per the norms of the Central / State pollution control board ) for old material as reqd.
Starting Capacitor 80-100 mfd
Running capacitor 36-50 mfd
Capacitor for Condenser Fan
Contactor relay for Split AC outdoor unit
Starting Relay
Thermostat
Fan blade for Window/Split AC unit
Blower Assembly for Split AC unit
PCB suitable for 1.5 /2 TR Split AC indoor/outdoor unit .
PCB suitable for 1.5/2 TR Invertor type Split AC unit.
Fan motor for Condenser unit 1.5 / 2 TR AC
Fan motor for Indoor unit of 1.5TR / 2 TR Split AC
Replacement of following type new Compressor of 1.5/2.0 TR for Split /Window /High Sensible AC unit i/c fixing , brazing , leak testing etc. as required ( The faulty compressor shall be handed over to the agency . The agency shall consider suitable credit for defective compressor while quoting the item)
Reciprocating type
Rotary type
Replacement of Condenser coil manufactured with copper/ brass tube for 1.5/2.0 TR Split AC unit i/c fixing , brazing , leak testing etc. as required ( The faulty coil shall be handed over to the agency . The agency shall consider suitable credit for defective coil while quoting the item)
Supplying & Charging of R22 / R410 / R134 gas for existng AC unit for topping up etc. as reqd.
Installation, Testing & commissioning of 1.5 TR Window A.C. unit on the existing MS Stand & making hole in existing window with properly finshing & minor civil work etc. complete as required.
Installation, Testing & commissioning (I/T/C) of wall mounted 1.5 /2.0 TR Split AC unit i/c installation of Condenser unit on existing M.S. stand, indoor unit on existing wall, providing nut bolts, making adequate hole in the wall for entry of copper pipes/tray, closing of holes, air gaps etc. after installation making testing commissioning etc. complete as reqd i/c fixing of existing Copper refrigerent piping brazing, leakage test, complete with wet servicing of Window / Split AC unit greasing of Fan motor, replacement of bush/bearing of fan / blower Motor, cleaning of condenser coil with caustic soda, washing of filters i/c removing and refixing AC unit, testing complete etc. as reqd.
Installation, Testing & commissioning of 2 x 1.5 TR High Sensible A.C. units indoor & outdoor unit on the existing MS Stand & making hole for refrigerant piping/Drain piping from indoor to outdoor & finishing it properly & making refrigerant piping properly by foam tubing & leak testing of line etc. complete as required.
Supplying and fixing of prefabricated M.S. powder coated stand having projection arm (set of 2 Nos) suitable for mounting outdoor unit of the above AC i/c providing necessary hardware support etc. complete as required.
Supplying and Fixing of MS iron stand made of suitable size for mounting outdoor unit of the above AC i/c cutting , welding , grouting , painting and minor civil works etc complete as required ( to be provided wherever wall stands are not feasible).
Supply & Fixing following size copper refrigerent pipes if required at site I/c cutting, bending, brazing etc. complete as reqd during installation.
1/2” Copper refrigeration pipe
1/4” Copper refrigeration pipe .
5/8” Copper refrigeration pipe
Providing and Wrapping of expanded polyethylene foam tube (heat lon) insulation on the existing refrigerent piping complete with clamping etc. as reqd.
For 1/2” Copper refrigeration pipe
For 1/4” Copper refrigeration pipe .
For 5/8” Copper refrigeration pipe
Laying of existing 2x2.5 Sq.mm. copper conductor unarmoured cable of 1.1 KV grade (ISI mark) directly on the surface of wall/tray including providing and fixing clamps etc. as reqd.
Supplying and Fixing 20 mm dia ISI mark heavy duty PVC pipe with accessories for drain water connection etc. as required.
SITC of twin AC Controller comprising of following accessories enclosed in suitable size sheet steel enclosure( approx size 400 mm 350 mm x150 mm) on din rail mounting alongwith necessary power wiring with 4 sqmm copper conductor cable & control wiring with 1.5 sqmm copper conductor cable etc. as reqd.
b) Timer FM1 Quartz - 1 no ( M/s GIC )
c) 63 Amp 8 way heavy duty connector & 1 no 2 Amp HRC control fuse with link -1No
c) 40 Amp single pole contactors (MR13) ( M/s L&T) - 2 nos.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .