| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | L1 | Accepted-AOC Negotiated the Lowest rate Quoted tenderer accepted | |
| 2 | L2₹21.4 L+₹52,309.40 (2.50%)Rejected-AOC | L2 | Rejected-AOC Rate quoted Higher than L1 Bidder | |
| 3 | L3₹21.8 L+₹86,373.64 (4.13%)Rejected-AOC | L3 | Rejected-AOC Rate quoted Higher than L1 Bidder |
Tender Value
₹20.2 L
EMD Value
₹20,100
Closing Date
12 Feb 2025, 5:00 pmClosed
Superintending Engineer
Office of Superintending Engineer pwd buildings construction and maintenance circle Madurai
Renewal and Replacement of 25 numbers of split type air conditioners along with its accessories in the Bungalows of the Honble Judges,Registrar Quarters and Doctor Quarters in the Madurai Bench of Madras High Court at Madurai
2025_PWD_520676_1
17/2024-25-1
Open Tender
Electrical Works
Lump-sum
90 days
Madurai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹20,100
20 Mar 2025
27 Jan 2025
13 Feb 2025
27 Jan 2025
12 Feb 2025
27 Jan 2025
Amount
Renewal by Supply, erection, testing and commissioningof 2.0TR (6000K.cal/ hr) ABS plastic Split type Inverter AC unit Conforming to IS.1391(part-2) with AMT 1 to 2 fitted with Inverter compressor operating on refrigerant non-CFC suitable fo wall mounting) except power consumpition norms suitable for operation on 230V.50Hz single phase AC supply with star rating of 5 as per BEE specification and capable of performing the function of 1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering The installation work for the above split type AC units inculds the following 1.Mounting /fitting indoor and outdoor units at their respective locations. 2.Laying refrigerant pipe line of required length connecting both units after drilling hole/holes in the wall if required.Thickness of the copper tubing shall not be less than 0.8mm. 3.Insulating the suction pipe with expanded polythYlene foam 5mm tubing. 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed with in Indoor unit. 5.Leakage testing the entire system. 6.Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit.(Carrier/O- General/Daikin). (SR)m1985)
Renewal by Supply and Installation of 5 KVA Electronic Automatic Voltage Stabilizer V- GUARD make VND 500 Model/Equivalent with Input Voltage range of 150 Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. (SR-M1989).
Renewal by Supply and Laying of 5/8inch and 3/8inch copper pipe (Extra beyond 3 meters supplied with AC unit) (SR-M1990)
Renewal by Supply and fixing of MS stand for fixing outdoor unit (SR-M1991)
Credit for Old Materials
ANNAI ELECTRICALS (BID ID -1248448)
T PAULKANNU & CO (BID ID -1248498)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .