Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-Finance | ₹3.1 L | L1 | Accepted-Finance Qualified |
| 2 | L2₹3.8 L+₹67,676 (21.8%)Accepted-Finance | ₹3.8 L+₹67,676 (21.8%) | L2 | Accepted-Finance Qualified |
| 3 | L3₹3.9 L+₹83,950 (27.0%)Accepted-Finance | ₹3.9 L+₹83,950 (27.0%) | L3 | Accepted-Finance Qualified |
| 4 | L4₹4.5 L+₹1.4 L (43.8%)Accepted-Finance | ₹4.5 L+₹1.4 L (43.8%) | L4 | Accepted-Finance Qualified |
| Sl No | Description | Qty | Unit | M/S YASHI ENTERPRISES L3 | MS VASHU ENTERPRISES L4 | M/S RAJ ASSOCIATES L1 | C B S ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00Carriage of followings from ESC BSR to pit site on kachcha pakkaa road including loading and unloading chagres at both ends, required completion of work, distance about to 0 to 70 Km. approx. | |||||||
| 2.00 | Battery Set 12 No.X02 Volt, 200Ah | 3 | Nos. | 1,000 ₹3,000 Lowest | 1,000 ₹3,000 Lowest | 2,000 ₹6,000 | 2,500 ₹7,500 |
| 3.00 | Battery Charger 24 Volt | 3 | Nos. | 1,100 ₹3,300 | 1,000 ₹3,000 | 500 ₹1,500 Lowest | 600 ₹1,800 |
| 4.00 | 11 KV VCB I/C | 2 | Nos. | 4,500 ₹9,000 | 4,000 ₹8,000 | 2,000 ₹4,000 Lowest | 2,500 ₹5,000 |
| 5.00 | 11 KV VCB O/G | 3 | Nos. | 4,500 ₹13,500 | 4,000 ₹12,000 | 2,000 ₹6,000 Lowest | 2,500 ₹7,500 |
| 6.00 | 33 KV LA | 9 | Nos. | 190 ₹1,710 | 500 ₹4,500 | 80 ₹720 Lowest | 100 ₹900 |
| 7.00 | 11 KV Cable Jointing Kit 3x185 Sq. Mm. O/D | 2 | Nos. | 150 ₹300 | 500 ₹1,000 | 30 ₹60 Lowest | 50 ₹100 |
| 8.00 | 33 KV VCB 800A, 750 MVA | 1 | Nos. | 5,200 ₹5,200 | 5,000 ₹5,000 | 3,000 ₹3,000 Lowest | 4,000 ₹4,000 |
| 9.00 | 33 KV C.T 400/200/1A | 3 | Nos. | 1,200 ₹3,600 | 1,000 ₹3,000 | 500 ₹1,500 Lowest | 600 ₹1,800 |
| 10.00 | 33 KV Control Pannel For Double T/F | 1 | Nos. | 4,000 ₹4,000 | 2,500 ₹2,500 | 1,000 ₹1,000 Lowest | 1,500 ₹1,500 |
Tender Value
Refer Docs
EMD Value
₹4,600
Closing Date
12 Jun 2026, 11:00 amClosed
SE, EDC-III BULANDSHAHR
SE, EDC-III BULANDSHAHR
Work related to protection and strengthening of 33 11 KV substations in the jurisdiction of Electricity Distribution Division Jahangirabad under the DPR approved in the Business Plan for the year 2026-27
2026_PVVNL_1152464_1
26/EDC-III/B/2026-2027
Open Tender
Electrical Works
Lump-sum
30 days
SE, EDC-III BULANDSHAHR
Work related to protection and strengthening of 33 11 KV substations in the jurisdiction of Electricity Distribution Division Jahangirabad under the DPR approved in the Business Plan for the year 2026-27
2 documents required · 2 mandatory
₹1,180
Yes
SE, EDC-III BULANDSHAHR
₹4,600
Yes
16 Jun 2026
23 May 2026
12 Jun 2026
23 May 2026
12 Jun 2026
23 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Carriage of followings from ESC BSR to pit site on kachcha pakkaa road including loading and unloading chagres at both ends, required completion of work, distance about to 0 to 70 Km. approx. | - | - | - | - |
| 2 | Battery Set 12 No.X02 Volt, 200Ah | 3 | Nos. | - | - |
| 3 | Battery Charger 24 Volt | 3 | Nos. | - | - |
| 4 | 11 KV VCB I/C | 2 | Nos. | - | - |
| 5 | 11 KV VCB O/G | 3 | Nos. | - | - |
| 6 | 33 KV LA | 9 | Nos. | - | - |
| 7 | 11 KV Cable Jointing Kit 3x185 Sq. Mm. O/D | 2 | Nos. | - | - |
| 8 | 33 KV VCB 800A, 750 MVA | 1 | Nos. | - | - |
| 9 | 33 KV C.T 400/200/1A | 3 | Nos. | - | - |
| 10 | 33 KV Control Pannel For Double T/F | 1 | Nos. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.81 MB
26NIT.pdf
Tender Documents • 2.79 MB
BOQ_2158911.xls
BOQ • 0.29 MB
DATEEXTEND.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .