Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹88.6 LAccepted-AOC | 1 | Accepted-AOC Work awarded w.e.f 01.05.2023 for two years period | |
| 2 | 2₹91.1 L+₹2.6 L (2.89%)Rejected-Finance BENGALURU URBAN KARNATAKA 560049 INDIA UDYAM KR 03 0026295 | BENGALURU URBAN | KARNATAKA | 560049 | 2 | Rejected-Finance L2 | |
| 3 | 3₹97.7 L+₹9.1 L (10.3%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | 3 | Rejected-Finance L3 | |
| 4 | 4₹1.0 Cr+₹13.3 L (15.0%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | 4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | - | Rejected-Technical Not meeting NIT criteria |
| Sl No | Description | Qty | Unit | GLOBAL TECH SERVICES L2 | CENTRE TAP ENGINEERING L3 | KALKI ELECTRICALS L1 | DElite System Engineering (India) Pvt. Ltd. L4 |
|---|---|---|---|---|---|---|---|
| 1.00SH-I: JOB CONTRACT OF E&M INSTALLATIONS | |||||||
| 1.10 | Job Contract for round the clock Operation and maintenance of Electrical and Mechanical installations in AAI occupied area at KIA viz. Technical Block cum ATC tower (Alpha-1 & 2 building), SMR at ARFF, North side New DVOR and Navigational huts i.e localizer-09,27, Glide path-09,27 including the operation of 200KVA DG set along with the AMF panel at RADAR building etc., with following categorised Manpowers :-
a) Highly skilled - 2 Nos, b) Skilled-7 Nos, c) Semi-skilled-4 Nos, d) Un-skilled-3 Nos.
All days including sundays and holidays in Three shifts & General shifts (Sunday weekly off ) which involves repairs & maintenance, attending day to day complaints, faults, breakdowns and taking rectification action, ensuring the serviceability & satisfactory working condition of the installations i/c preventive maintenance, maintenance of records & documentations etc., The agency is required to deploy minimum manpower in each shift as detailed in special condition of contract complete as required. | 24 | MONTHS | 3,66,402 ₹87,93,648 | 3,85,000 ₹92,40,000 | 3,55,000 ₹85,20,000 Lowest | 3,96,609 ₹95,18,616 |
| 2.00SH-II: DSR ELECTRICAL -2022 | |||||||
| 2.10 | Execution of items of schedule of rates CPWD DSR (E&M)-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in Alpha-1 & 2 building, ATC tower, NAVAIDS and other ancillary buildings as per the special Terms and Condition in addition to General Terms and Condition of Contract as required. The bidder shall quote percentage (%) above / below the DSR (E&M)-2022 rates in the form of multiplication factor i.e ( for eg :- If the bidder desires to quote above on DSR (E&M)-2022 rates, then the rate column shall be filled as 1.05 & 5% below, then the rate column shall be filled as 0.95) .
Note : The rate provided in DSR (E&M)-2022 is inclusive of GST @ 12%. The rate shall be calculated without GST and payment shall be made to the contractor after deductingGST component from DSR E&M -2022 rates. | 1,00,000 | % | 0.8 ₹80,000 Lowest | 1 ₹1,00,000 | 0.9 ₹90,000 | 1 ₹1,00,000 |
| 3.00SH-III: Calibration & Testing of Air Circuit Breaker. | |||||||
| 3.10 | Annual inspection & Servicing of 4pole 415 V, 1600 Amps, Air Circuit Breaker of SIEMENS Make ; Model: WL l 1600 S through OEM or its authorized dealer by cleaning, checking, tightening, adjusting replacing defective components greasing oiling etc complete as required but without spare parts i/c Over load, Earth Fault, Short Circuit and insulation resistance testing through secondary injection kit, submission of test reports etc. | 4 | Each | 15,000 ₹60,000 | 10,000 ₹40,000 | 2,600 ₹10,400 Lowest | 6,599 ₹26,396 |
| 4.00SH-IV: Supply of Electrical spares/ items :- | |||||||
| 4.10Supply of following sizes of PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 690/1100 Volts conforming to IS:694:2010 etc complete as required | |||||||
| 4.20 | a) 3C X 1.5 sqmm | 100 | Mtr | 70 ₹7,000 Lowest | 100 ₹10,000 | 76 ₹7,600 | 99 ₹9,900 |
| 4.30 | b) 3C X 2.5 sqmm | 100 | Mtr | 75 ₹7,500 Lowest | 150 ₹15,000 | 98 ₹9,800 | 129 ₹12,900 |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
20 Mar 2023, 11:00 amClosed
AGM (E-E)
HAL AIRPORT, BANGALORE-17
Operation and Maintenance Contract (2023-25) of Electrical and Mechanical installations including associated works at AAI Occupied Areas at KIA, Bengaluru Airport
2023_AAI_147088_1
AAI / BG-KIA/OM and EM/2022-23
Open Tender
Electrical Works
Works
720 days
KIA, BANGALORE
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,120
₹2.1 L
30 Oct 2025
27 Feb 2023
21 Mar 2023
27 Feb 2023
20 Mar 2023
27 Feb 2023
27 Feb 2023 - 6 Mar 2023
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .