Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | ₹25.6 L Quoted ₹25.9 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹26.8 L+₹95,950 (3.71%)Rejected-Finance | ₹26.8 L+₹95,950 (3.71%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹40.1 L+₹14.2 L (54.9%)Rejected-Finance | ₹40.1 L+₹14.2 L (54.9%) | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
3 Feb 2022, 6:00 pmClosed
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8413/21/E8
2021_MES_488308_2
8413/21/E8
Open Tender
Civil Works
Item Rate
180 days
Vasco
Class D Category b i
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹76,000
Yes
23 Mar 2022
13 Jan 2022
5 Feb 2022
19 Jan 2022
3 Feb 2022
19 Jan 2022
14 Jan 2022 - 18 Jan 2022
Amount
M & L for finding out fault in high mast control panel and checking complete control wiring , rectifying the defects including replacement of old perisd spare parts , wiring , switch gears complete all as specified and directed by Engr-in-charge.
M & L for taking down of gear assembly along with motor of high mast hight upto 25 mtrs , rectifying the defects including rewinding of motor complete all as specified and directed by Engr-in-charge.
M & L for modifying the existing wiring for dispersal light of Hangars/ building connect the same with timer panel for timely ON/OFF switches and for saving of energy complete all as specified and directed by Engr-in-charge. ( Note :-1. Timer panel are issued under schedule 'B' 2. Sub main wiring will be measured and paid seprately under connected items)
S & F in repairs Surge protection devices type -2, 4 pole in sheet steel enclosure and testing and commissioning with screw. nuts and bolts etc. all as specified and directed by Engr-in-charge. (Make :- L&T/ HPL/Havells)
Supply and fix in repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole/high mast pole/wall by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed. (Make:- Bajaj cat part No.BARFEG 200 LED or equivalent Philips/CG)
Supply and fix in repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole/high mast pole/wall by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed by Engr-in-charge. (Make:- Bajaj cat part No.BARFEG 240 LED or equivalent Philips/CG)
Dismantling the existing electric chimney system of 5 HP blower motor capacity complete by disconnecting all incoming and outgoing elect connections carefully along with blower motor, hood, hood cover, ducts, etc. removing the carbon / dust / oil layer from the inside wall of complete inlet / outlet ducting and hood system thoroughly by using kerosene / high pressure water jet wash / suitable solvent and re-assembling the same after completion of repair / cleaning work incl the following works :- (a) Alignment of whole system inlet and outlet blower assy with motor for smooth functioning incl greasing of blower and motor bearings. (b) Replacement of GI Sheet for 5 HP blower motor cover - 01 No (c) Replacement of new rubber gasket for GI inlet / outlet duct flanges with new GI nut bolt and washers of suitable size. (d) Arrest the vibration of ducts by using suitable arrangements such as angle iron support, rubber pads, anchor bolts complete upto recommended level. (e) Painting of GI inlet / outlet ducts along with MS flanges and nut, bolts in the outer side by means of synthetic enamel paint two coat over a coat of red oxide primer.
(e) Fabrication and fixing of strainer made out of MS wire 3 mm thick having 20 mm width of duct outlet opening size. (f) Connecting of elect cables to blower motor / suction motor (g) Cleaning of inlet and blower fan and painting with one coat of synthetic enamel paint by using spray gun. (h) Repairing the blower fins by denting , painting and trimming and making good. (j) Applying one coat synthetic enamel paint to Blower motor, suction fan with blade by spray after cleaning the outer surface area complete. (k) Other minor works such as grouting, supporting clamps, nut bolt and washers incl replacement of tarpaulin cloth of existing size to make the plants smooth functioning.. (Location : POs , MCPOs ) (Note : New spares like GI ducting, MS angle iron works, cables, motor winding and starter will be measured and paid separately under relevant item of this schedule)
S & F in repairs incl fabrication of Air inlet / outlet duct made up of GI Sheet 1.0 mm thick with connecting / supporting flange, rubber gasket, fixing clamps, nut, bolt and washers as per existing size and shape complete all as directed.
S & F in repairs ball bearing for blower shaft - 02 Nos & blower motor - 02 Nos suitable for 5 HP capacity blower motor Chimney all as directed.
S & F in repairs ball bearing for blower shaft - 02 Nos & blower motor - 02 Nos suitable for 10 HP capacity blower motor Chimney all as directed.
S & F in repairs canvas cloth suitable for Elect Chimney's Air inlet / outlet GI duct joints / extension incl replacement of old nut, bolt and washers complete all as directed
S & F in repairs Air suction fan with blade 5 HP capacity Elect Chimney three phase with blade of existing capacity / rating / model and size and fixed in position all as directed.
Disconnecting the motor from the blower assy of any make / model electric driven AC 3 phase, 415 Volts any make / model from any Elect Chimney's transporting to workshop dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing and re-installation at same position including commissioning and testing complete all as specified. (Minor spares such as repair / replacement of terminal box, terminals, fan blade shall be deemed to included in the quoted rates)
S & F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified and directed by Engr-in-charge. (Make: Bajaj Cat No BGAV 302 LED or equivalent in Philips/CG)
S & F in repairs 1x60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified and directed by Engr-in-charge. (Make : Bajaj Cat No ENXT P 60L WW CR PC SD or equivalent in Philips/CG)
M & L for in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc all as specified and directed by Engr-in-charge.
S & F in repairs wind LED wellglass luminaires 1x30 watts Energy saving, environment friendly & robust open type vertical LED luminaire with high power LED as light source all as specified and as directed. (Make : Bajaj Product No BIWDN 30W LED equivalent in Philips/CG)
Fixing only LED High bay luminaires of any make any type of capacity 80 W to 140 W in hangar upto height of 18 mtr including making necessary electric connection and removal of old unserviceable lights and depositing to MES yard comlete all as specified and directed by Engr-in-Charge. Note :- (a) Highbay lights will be supplied under Sch B items.
S & F in repairs LED High bay luminaires 1x195 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engr-in-charge. (Make : Bajaj Product No BGHBM NXT B 196W WH NB SD equivalent in Philips/CG)
S & F in repairs LED High bay luminaires 1x200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engr-in-charge. (Make : Bajaj Product No BGHBM NXT B 200W WH NB SD P 200W or equivalent in Philips/CG)
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish all as specified and directed by Engr-in-charge.
M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping/ FRLS pvc conduit (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc all as specified and directed by Engr-in-charge. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
Ditto all as per item No 23 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor.
Ditto all as per item No 23 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor.
Ditto all as per item No 23 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor.
Ditto all as per item No 23 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor.
Ditto all as per item No 23 here in before, but four run of single core 16 sqmm and two runs of 10 sqmm cables as earth continuity conductor.
S & F in repairs Switch Flameproof WP Rotary type with termination box in LM6,15A single pole 250V all as specified and directed by Engr-in-charge.
S & F in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth all as specified and directed by Engr-in-charge.
Supply and fixing LED light fitting 30 Watt flame proof 4 feet long, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectio with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Make :- bajaj/C&S/Cromton greaves
Supply and fixing in repairs flame proof exhuet fan motor with body of size 300 mm sweep complete all as specified and directed by Engr-in-charge. Make :- bajaj/C&S/Cromton greaves
Supply and fixing in repairs flame proof exhuet fan sweep of size 300 mm sweep complete all as specified and directed by Engr-in-charge. Make :- bajaj/C&S/Cromton greaves Note:- Fan Blade make and size should be supply with the mach of under relivent item of Sch A serial No 22 as above.
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and directed by Engr-in-charge.
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
All as per item No 35 here in before but MCB DB TPN 4 way DB 415 V with 200 A rated busbar triple pole.
S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and directed by Engr-in-charge.
All as per item No 37 here in before but MCB DB SPN 4 way DB 230 V with 200 A rated busbar.
All as per item No 37 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
S&F in repairs MCCB DB TPN, 8 way, (MCCB + 24 way O/G) double door, vertical type provision one MCCB of 100 amps breaking capacity 18 KA, 4 pole without MCB complete all as specified and directed by Engr-in-charge.
S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB TPN 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make :- L & T Cat No CM90634OOMO or equivalent
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T Cat No CM90634OONO or equivalent
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T Cat No CM9634OOPO or equivalent
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T Cat No CM98404OORO or equivalent
Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 18 KA , 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's c complete all as specified and directed by Engr-in-charge. (Make : L&T Cat No CM90677OOLO or equivalent in C&S/Legrand)
Supply and fix in repairs MCCB of 63 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's c complete all as specified and directed by Engr-in-charge. (Make : L&T Cat No CM9051OOHO or equivalent in C&S/Legrand)
Fixing only Energy efficient surface Mounted LED Luminire 18/20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr and removal of old unserviceable lights and depositing to MES yard comlete all as specified and directed by Engr-in-Charge. Note :- (a) LED tube lights fittings will be supplied under Sch B items.
Fixing only recess mounting high lumenLED flat panel 2'X2' 36 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessary fixing arrangement at any height and removing old unserviceable ans depositing to MES yard comlete all as specified and directed by Engr-in-Charge. Note :- (a) LED tube lights fittings will be supplied under Sch B items.
Fixing only Energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr etc.and necessary fixing arrangement at any height and removing old unserviceable ans depositing to MES yard comlete all as specified and directed by Engr-in-Charge. Note :- (a) LED tube lights fittings will be supplied under Sch B items.
Supply & fix recess mounting high lumenLED flat panel 1'X1' 18 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed by Engr-in-charge. (Make:- Bajaj Cat No - BZRSQL 18 W WH or equivalent in Philips/CG)
Supply & fix in repairs recess mounting high lumen LED flat panel 4'X1' 36 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed by Engr-in-charge. (Make:- Bajaj Cat No - BZSSLL 36W LED WH or equivalent in Philips/CG)
S&F in repairs LED light fitting 1x18 watts Surface mounted LED downlighter in powder coated white finish with integrated electronic driver complete all as specified and directed by Engr-in-charge. (Make :- Bajaj Cat No BGSLO Sleek 18W WH RD or equivalent in Philips/Wipro).
Supply and fixing LED light fitting 1x16 Watt flame proof 4 feet long, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed by Engr-in-charge.
S & F in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed.
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials complete all as specified and directed by Engr-in-charge. .
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
S & F copper strip 20x3 mm Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-charge.
Supply and wrapping of LT insulation tape 12 mm width in 5 mtr roll complete all as specified and directed by Engr-in-charge. (Make : 3M / M-Seal / Raychem / RPG or equivalent)
S & F in repairs lead acid battery 12 Volt 90 AH for fire detection system complete all as specified and directed by Engr-in-charge. (Make : Exide express or equivalent in TATA / Amaron)
S & F in repairs connecting and commissioning sealed maint free battery 12 volts 42 AH . Make : Exide
S & F in repairs connecting and commissioning sealed maint free battery 12 volts 7 AH . Make : Exide
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engr-in-charge.
S & F Perforatted cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified.
S&F in repair informatory sign boards/display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 mtr x 1 mtr) fixed on wall with screw. nuts and bolts etc. complete all as specified and directed by Engr-in-charge. Note :- wright matters will be provided by departmaint as per requirment.
M & L for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out goining MCB/MCCBS complete all as specified and directed by Engr-in-charge.
S & F in repairs capacitor of 2.5/3.15 mfd capacity for ceiling fan of any sweep complete all as specified and directed by Engr-in-charge.Make :- L & T Cat No AUTS01ANA00 or equivalent
S&F in repair Analog time switch fixed in timer panal including connection with screw. nuts and bolts etc. complete all as specified and directed by Engr-in-charge.
Taking down Aluminum strip of size 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and supply and fixing in repairs Aluminum strip of size 25x3.15 mm the same location with new nuts and bolts, screws of suitable size and length and connected to air termination rod complete all as specified and directed by Engr-in-charge.
RENDERING SERVICES FOR SEWAGE TREATMENT PLANTS AND WATER SUPPLY INSTALLATION OF HANSA VIHAR AREA UNDER AGE E/M -I OF GE (NW) VASCO
Dismantling air compressor blower for checking and carrying out repairs by replacing old/unserviceable parts, grinding, polishing of cylinder pistons, replacement of piston rings, inlet and exhaust rods and reassembling after repair and re-installing aqnd testing including one coat of synthetic approval enamel paint after preparation of surface complete for smooth functioning all as directed by Engineer-in-Charge.
Supply and replacement of compressor oil complete all as directed by Engineer-in-Charge. (Make :- Servo, Castrol)
Supply and mix Bleaching powder calcium based, high strength chlorination chemical for water disinfectant chlorine concentration level 65-70% ISI Marked all as specified and directed by Engineer-in-Charge.
Cleaning of collection tanks/septic tanks of various capacities by De-watering of Sewage Water, Removing of settle down Sewage sludge cum mud/De-Silting etc. including cleaning of wall and bottom surface of collection tank by scraping down with wire brush all as required at site and directed by the Engineer-in-Charge .
(a) Collection tanks of capacity 10m3
(b) Collection tanks of capacity 15 m3
(c) Collection tanks of capacity 30 m3
(d) Collection tanks of capacity 60 m3
NOTE FOR ITEM NO. 69.00 (a) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes (b) Tractor mounted septic storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Delhi Canttonment Board/PCB (c) Sewage Sludge disposable tractor/ truck with driver and POL required for the same (duly covered with necessary tarpaline) and disposing the same to the location outside the MoD land all as on required basis and as directed.
(d) Labour element and T&P required for removal of settled down sewage sludge / mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal as directed. (e) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank and all as directed by the Engineer-in-Charge. (f) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (g) The Contractor shall provide Necessary tools, Plant, materials and labour for item No 69.00 (a) to & 69.00 (f) and the cost of the above is deemed to be included in the quoted rates.
Testing of treated water of STP and submission of detailed test report to the office of the Engineer-in-Charge and testing in Govt. approved laboratory as approved by GE/Directorate of Health Services (Enviormental and pollution Control Wing, Panaji-GOA). (a) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, PH value, sulphate, Oil grease, TSS, BOD, COD residual chlorine and Bacteriological total collifrom organisms per 100 ml (MPN) and E collie in 100 ml)
Note :- Rate quoted shall deemed to be included for :- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of sample
star freeze service
LITE SYSTEMS INDUS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .