Providing FHTCs to 39 Households In SINGAPURA Habitation Of RAMACHANDRAPURA Village, Grampachayth of RAMACHANDRAPURA HOSANAGARA talukSHIMOGA district through SVS
02 79 112-Double Pole TC sets for erection of 25/63/100kVA 4/5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - MS
Erection of Transformer structure Upto 25/63 KVA - Ordinary Soil
02 00 105-RCC Pole-9.0M
Digging of Pits 1.8 mtr depth for errection of 9 to 10 mtr Long Steel/ RCC/PSC supports as per approved Drawing - Ordinary Soil
Erection of RCC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth. - Ordinary Soil
02 81 674-GI Grounding pipe, B - Class, 42mm dia,
2.5mtrs long, 3.2mm thick with bolts nuts, GI Strips and washers complete
Digging of pit. For providing GI Pipe type Earthing - Ordinary Soil
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits) - Ordinary Soil
02 81 008-8 SWG GI Wire
02 83 320-Silcon rubber composite disk insulator/11kV 45 kN Polymeric insulator
02 83 007-11kV Pin Insulator (Both Shell and G.I. Pin) - Polymeric
02 79 092-HT ST Support - MS
Fixing of HT/LT single top support . - Ordinary Soil
Guy set with 2Nos. 15 strain insulator & Concreting materials as per Drwg No.BESCOM/GM/CP/7/Dt; 24.10.07
Digging of Pit for GUY SET - Ordinary Soil
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) but...
Aluminium Wdg, BEE 4 Star Rated Open Bushing Type Distribution Transformers 3 Phase, 11kV/433V- Stacked Core with Oil
Erection of 25 kVA Transformer on Transformer structure. - Ordinary Soil
Transporting one pole - Head Load - Not payable for distance less than 25 Mtrs
Loading and unloading of poles (loading of poles to vehicles at stores and unloading at workspot) - 9 mtr RCC/PSC poles
lightning Arrester Polymeric type with Ground Disconnector
Fixing of lightning arrestors including wiring. - Ordinary Soil
03 01 107-LT Protection kit
Fixing of LT Protection Kit - Ordinary Soil
03 01 151L.T.Wiring kit For 25 kVA DTC single circuit
Wiring of One circuit of LT Wiring Kit for for25/63/100 KVA DTC to the existing LT protection KitKit / Distribution Box via metering box. - Ordinary Soil
Single Break GOS
Fixing of GOS including wiring g (11kV SB 200A) - Ordinary Soil
03 02 011-11 kV DOLO
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring - Ordinary Soil
02 00 105-RCC Pole-9.0M
Digging of Pits 1.8 mtr depth for errection of 9 to 10 mtr Long Steel/ RCC/PSC supports as per approved Drawing - Ordinary Soil
Erection of RCC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth. - Ordinary Soil
02 00 006-PSC Pole-9.0M
Digging of Pits 1.8 mtr depth for errection of 9 to 10 mtr Long Steel/ RCC/PSC supports as per approved Drawing - Ordinary Soil
Erection of PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth. - Ordinary Soil
Special 3 Pin Cross Arm, clamp and Bolt & Nuts for RCC Poles - MS
Fixing of 3 pin special cross arms with clamps, bolts, nuts and washers - Ordinary Soil
11 kV Horizontal Cross Arm with single top support, clamp, Bolt & Nuts with washers for PSC Poles - MS
Fixing of V-Shape/Horizontal cross arm including single top support Braces and Insulators fixing. - Ordinary Soil
02 79 092-HT ST Support - MS
Fixing of HT/LT single top support . - Ordinary Soil
2 Pin Cross Arm with pole clamp, bolts & nuts & washers for PSC Pole - MS
Fixing of 2 Pin cross arm with insulator and Braces fixing - Ordinary Soil
02 83 007-11kV Pin Insulator (Both Shell and G.I. Pin) - Polymeric
02 83 320-Silcon rubber composite disk insulator/11kV 45 kN Polymeric insulator
02 83 053-1.1kV GI Pin FOR
1.1kV Cermaic shell Insulator
02 83 003-1.1kV Ceramic Pin Insulator (Shell only)
02 83 158-No8 Strain Insulator
Guy set with 2Nos. 15 strain insulator & Concreting materials as per Drwg No.BESCOM/GM/CP/7/Dt; 24.10.07
Digging of Pit for GUY SET - Ordinary Soil
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) but...
02 84 108-Rabbit ACSR
Stringing of conductor Rabbit ACSR binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. - Ordinary Soil
02 81 683-Spiral Earth Electrode
Providing spiral earth electrode type earthing along with pole (without charcoal, salt etc.,) - Ordinary Soil
Transporting one pole - Head Load - Not payable for distance less than 25 Mtrs
Loading and unloading of poles (loading of poles to vehicles at stores and unloading at workspot) - 9 mtr RCC/PSC poles
Releasing and Refixing
construction of new line including Trimming of Trees, if Jungle/Tree/Plant/ Shrubs Exists Malnad/Hill Area
Dismantling work-PSC Pole-8.0M Long 200 kg WL
02 00 103-RCC Pole-8.0M
Digging of Pits 1.5 mtr depth for errection of7.5/8 mtr Long Steel/RCC/PSC/PCC supports as per approved Drawing - Ordinary Soil
Erection of RCC poles of 7.5 to 8 mtr long in pit of 1.5 mtr depth - Ordinary Soil
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC Pole - MS
Fixing of 4 Pin cross arm with insulator and Braces fixing. - Ordinary Soil
02 83 158-No8 Strain Insulator
Guy set with No. 8 strain insulator & Concreting materials as per Drwg No. BESCOM/GM/CP/7/Dt; 24.10.07
Digging of Pit for GUY SET - Ordinary Soil
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) - ...
Transporting one pole - Head Load - Not payable for distance less than 25 Mtrs
Loading and unloading of poles (loading of poles to vehicles at stores and unloading at workspot) - 8 mtr RCC/PSC poles
03 57 202-3 Phase(KWH
Meters Static) 5-30 Amps
03 57 515-LT Three phase Four Wire 5-30A Thread through type composite Meter Housing Box consisting of ETV Meter with AMR comply and LTCT with built in GSM/GPRS modem upto 100kVA Distribution Transf...
Electrical Inspectorate
Charges ( @ 0.00 Amount of ())
Goods and Service Tax (GST): CGST , SGST, IGST (
@ 18.00 Percentage of (Labour + Works + Stock Materials ))
Area Specific Loading(@12% Restricted areas/Jails/Forest/Hazardous&B Works/Sewerge
Works/Works Under Unhygienic/Coastal area/Heavy Rainfall area/Tidal Wave area/Hilly Terrain) ( @ 12.00 Percentage of ...
MESCOME DEPOSITS (OVERHEADS)
02 84 108-Rabbit ACSR
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .