Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹1.6 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.7 Cr+₹5.8 L (3.55%)Rejected-Finance 325 PANCHWATI ENCLAVE SHATABDI NAGAR DELHI ROAD MEERUT UP 250103 | MEERUT | UTTAR PRADESH | 250103 | ₹1.7 Cr+₹5.8 L (3.55%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹1.7 Cr+₹6.7 L (4.12%)Rejected-Finance 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹1.7 Cr+₹6.7 L (4.12%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹1.7 Cr+₹7.6 L (4.69%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | ₹1.7 Cr+₹7.6 L (4.69%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹1.9 Cr+₹27.3 L (16.8%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹1.9 Cr+₹27.3 L (16.8%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
27 Feb 2025, 6:00 pmClosed
CE BAREILLY ZONE
HQ CE BAREILLY ZONE
PROVN OF QUARTER GUARD AND KOTE AT RVC CENTRE AND COLLEGE MEERUT
2025_MES_691987_1
CEB/MRT/ T-41 OF 2024-2025
Open Tender
Civil Works
Lump-sum
365 days
MEERUT
as per tender
8 documents required · 8 mandatory
₹1,000
GE (P) MEERUT
₹3.8 L
Yes
23 May 2025
6 Jan 2025
6 Mar 2025
6 Jan 2025
27 Feb 2025
4 Feb 2025
Amount
SCHEDULE 'A' PART - I (BUILDING WORK)
Construction of OTM Accn for Quarter guard and Kote (Single story) complete all as specified and shown on drawings.
Construction of Flag staff including base complete all as specified and shown on drawings.
Construction of Alarm Post complete all as specified and shown on drawings.
SCHEDULE 'A' PART - II (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - III A (Internal Electrification) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - III B (Internal Electrification)
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multistra-nded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e. modular switch /sockets incl cover plate with frame including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - (Note: Rate for modular plate and frame is deemed to be included in quoted rate)
(a) One light point /bell buzzer/ ceiling fan / Exhaust fan point controlled by one-one way switch.
(b) One three pin 5 Amp socket on same board with other switches.
(c) One three pin 5 Amp socket on independent board
All as per item No 5 above, but point wiring with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm for one 3 pin socket outlet 15 Amp independent
All as per item No 5 above, but point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm.
Supply & fix LED lamp 12 watt, 220 volt AC decorative type connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required complete all as specified and directed.
Supply & fix flame proof switch socket & plug combined in LM6 cable tremination box in LM6, 6 A, 250 volts, 2 P+earth complete all as specified and directed.
Supply & fix flame proof distribution board SPN 8 way with flame proof MCB SPN 32 Amps - 01 No. and MCB SP-06 Nos double door IP-54, 200 Amps rating bus bar complete all as specified and directed.
Supply and fixing exhaust fan steel body flame proof AC single phase 230V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed.
Supply and fixing ceiling fan steel body flame proof AC single phase 230V of size 1200 mm sweep with blades and frame and louvers complete all as specified and directed.
Supply, installing testing and commission-ing of water heater storage type bee 5 star rating electric suitable for single phase, 50 Hz, AC supply, stainless steel inner assembly, 1.5 KW heating element, twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1 m of three core 2.5 sqmm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450 long of 6 kg/sq cm with two sets of chromium plated adopter at each end suitable for 15 mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at end washer at hot water outlet, with safety fusible plug NRV confirming to relevant IS of 25 ltr capacity complete all as specified and directed.
Supply & fix rigid non metallic PVC conduit exclusiveof boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc 20 mm dia complete all as specified and directed.
SCHEDULE 'A' PART - IV (Site Clearance and Earth work) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - V (Hard standing & Culvert) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - VI (Sewage Disposal) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - VII (Area Drainage) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - VIII A (Fencing / Gate/ Security wall) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - VIII B (Fencing / Gate/ Security wall)
S&F 610 mm dia pinched tape concertina coil (effective dia 550 mm at stretch, length of coil 6.00 m) two handle and spikes at both the ends of coil with dove tail clips (18 SWG) including razor wire (07 Nos) 6 m length in each wire with medium size, barbed length 20 mm and barbed 14 mm including 51 pins 128 N of clips in each coil including 230 gm/sqm zinc coating on core complete all as specified and directed.
SCHEDULE 'A' PART - IX A (External Water Supply) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - IX B (External Water Supply)
M&l for brick masonery valve pit internal dimension 950 mm x 950 mm x 900 mm incl necessary excavation and earth work 50 x 6 mm angle iron frame hold fasts MS sheet cover 3 mm thick, handles, locking arrangement with 1 No lock of size 50mm complete all as specified and directed.
SCHEDULE 'A' PART - X A (EXTERNAL ELECTRIFICATION) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - X B (EXTERNAL ELECTRIFICATION)
Design, Supply, fabrication, installation testing and commissioning (CPRI approved) 440/400V AC LT Panel, outdoor (Kisok) type, Compartmentalized, Modular, outdoor type in 3.15 mm CRCA sheet of appropriate size, front operatable double doors, front & back openable double doors, front & back openable only, dust & vermin proof, Cable ENTRY THROUGH 3.15 MM CRCA GLAND PLATES- bottom only, powder coated after 7 - Tank pre treatment process Siemens Grey shade on body/doors & orange shade on mounting/gland plates, incomer doors 3 Phase HR sleeved colour coded alumin-ium main busbar of 200 Amp - 3 Nos along with neutral half busbar and transpent FRP Covers & on SMC/DMC support, 25X3 mm aluminium earth bus bar running across the length of LT Panel with 2 Nos studs at both the sides ends. Lifting arragement/ hooks at the top, wiring with appropriate size of
copper industrial cables, black painted base frame - 40X40X6 mm MS angle including danger plate of different sizes suitable for incoming and outgoing ACB and MCCBs and fitted with following specified items:- INCOMING:- (a) MCCB 4P, 415V, 63 Amps, with rupturing capcity 16 KA - 1 No. OUTGOINGS:- (b) MCCB TP, 415V, 63 Amps, with rupturing capcity 16 KA - 02 Nos
(c) MCB SPN, 230 V, 32 Amps, with rupturing capcity 10 KA - 02 Nos (d) Digital voltmeter 0-500 V - 01 No, Digital Ampere Meter 0- 200 Amp- 01 No (e) RYB phase indicating lamp LED type -03 Nos (f) Aluminium busbar 200 Amps with air insulated for TPN - One set (g) Timer switches 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure for street light fittings. (h) Panel wiring with 2.5 sqmm copper cable PVC single core - 1 Job (j) PCC plateform with foundation 1:2:4 = 1 Job
Excavation by trenchless tech, Boring of holes under road pavement, hard standing by srencheless techonology using ultra sounding rechnique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure.
M&L for pole box fabricateed out of 1.8mm thick MS sheet having 3 nos busbar 50Amp copper conductor mounted on insulators one no 20x3mm copper bus bar with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc size of box not less then 100x200x80mm front openable hinged cover suitable for mounting on steel using clamps nut bolt etc pvc adopteers and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
S&F GI pipe light grade 40 mm dia as in wall / pole mounting bracket and 1.5 m long fixed to wall with and including nut bolts and MS clamps of size 50 x 4 mm as required including two coat of synthetic enamelled paint over a coat of primer complete all as specified and directed.
SCHEDULE 'A' PART - XI A (WATER COOLER & DESERT COOLER) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - XI B (WATER COOLER & DESERT COOLER)
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 05%% and of capacity 1 KVA complete all as specified and directed.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel body complete all as specified and directed.
SCHEDULE 'A' PART - XII (LIGHTENING PROTECTION) for details refer Sch A in pdf folder
SCHEDULE 'A' PART - XIII (ARBORICULTURE)
Supply and plantation of green sapling of following plants and shrubs of different species 2' to 4' ft high incl preparation of compost of size 300x300x300mm by excavation, applying ATT, planting the trees / plants refilling the pit with compst manure sand and sweet earth in the ration 1:1:4 breaking the clots, ramming and flooding with water and filling with more compost earth if necessary, fine dressing incl removal of rubbish / unserviceable material. ATT shall be in form of 200 gms Neem cake mixed with every cum of compost followed by dursban 20 EC applied at 2ml / litre in the first watering of 20 ltr per pit complete all as specified and directed:-
Ashok
Areca Palm
Staking of plant with bamboo of 2.50 m height, grounded to 1.0 m depth below ground and tying with sutli at 3 places, to secure the plant against wind or any other disturbance complete all as directed.
Supply and fixing M S tree guard 45 cm square in plan, height 1.20 m above ground level and 0.40 m below ground level. The vertical members shall consist of 04 Nos angle iron of size 25x25x3 mm, 1.8 m long, one at each corner and 8 Nos flat iron of size 25x3 mm, 1.2 m long. The vertical mambers shall be welded to 4 Nos 25x6 mm MS flat iron placed horizontally around the vertical member of the cage. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered any approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer complete in all respect.
SCHEDULE 'A' PART - XIV (DISMANTLING / DEMOLITION) for details refer Sch A in pdf folder
NOTE:-Tenderers may plaese note that amount of Schedule of Credit as given on Page No. 66 shall be deducted at the time of acceptance of tender to arrive the contract sum.
M/S Keshav Brothers (BID ID -3243625)
Arun Construction Co. (BID ID -3236842)
SA construction co. (BID ID -3237253)
Sudhir Sharma Associates (BID ID -3233126)
m/s gupta construction (BID ID -3236686)
CHITTER MAL & CO (BID ID -3237060)
NARESH KUMAR AND COMPANY (BID ID -3251385)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .