Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-Finance | L1 | Accepted-Finance AS PER BOQ | |
| 2 | L2₹6.8 L+₹9,010 (1.35%)Accepted-Finance GRAM POST MAWANA KHURD MAWANA MEERUT | MEERUT | UTTAR PRADESH | 245206 | L2 | Accepted-Finance AS PER BOQ | |
| 3 | Rejected-Technical | - | Rejected-Technical Not proper Balance sheet | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Tender cost and Emd |
Tender Value
₹6.8 L
EMD Value
₹6,750
Closing Date
16 Dec 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle II Saharanpur
Various work of deposit scheme in area EDD RAMPUR MANIHARAN SRE
2024_PVVNL_982480_1
76/W/EDC II/SRE/2024-25
Open Tender
Electrical Works
Lump-sum
30 days
SAHARANPUR
Please refer tender document
2 documents required · 2 mandatory
₹1,180
SE EDC II SRE
₹6,750
9 Jan 2025
10 Dec 2024
16 Dec 2024
10 Dec 2024
16 Dec 2024
10 Dec 2024
Amount
Detail of Work
Safe cartage of PCC poles up to (8.5 Mtr. Long) from ESC, SRE to site of work including loading & unloading at both ends.
Safely cartage of other complete line material ACSR Weasal conductor/ABC cable (Except PCC Pole) from ESC, SRE to site of work including loading, unloading at both ends.
Safely carriage of 100 (01 No)/250 (02 No) KVA T/F ESC, SRE to site of work including loading & unloading at both ends..
Erection of single support on PCC poles up to (8.5 Mtr. Long) with complete fitting of all accessories as per RESPO specification.
Erection of double Pole on PCC poles up to (8.5 Mtr. Long) with complete fitting with all accessories as per RESPO specification.
Concreting of stay rod in bolck of 600X600X1500 MM. in ratio 1:4:8 with with cement, sand and brick ballast size 1''x1.5'
Earthing of poles by earthing .
Laying, lifting, stringing, sagging jumpering & binding of ACSR Weasal Conductor for 11KV Line as per RESPO specification.
Laying, lifting, Stringing, proper sagging of ABC cable of size 3x95+1X50+1X16 sq.mm. including fixing of all tall accessorie.
Laying, lifting, Stringing, proper sagging of ABC cable of size 3x50+1X35+1X16 sq.mm. including fixing of all tall accessorie.
Laying and making connections of LT PVC/XLPE cable 3.5x70 sq mm./3.5x9/1x240 sq mm. from T/F to double pole (approx to 20 mtr.)
Fixing of 11 KV Fuse set.
Providing & Fixing nuts & bolts of various sizes.
Fixing of Distribution Box of Single Phase/3-Phase on PCC Pole with Providing suitable clamp and connection above Distribution Box with ABC cable connecting jumpering including with service connection.
Providing of J-HooK Clamp for PCC Poles with nuts bolts made of new MS flat iron 50x6 mm with nuts bolt.
Providing and Fixing of double pole clamp on PCC Poles with nuts bolts made of new MS flat iron 50x6 mm as per RESPO specifications.
Providing and fixing Pearcing connector for PCC Poles made of new MS flat size 50/35 sqmm. as per RESPO specifications.
Providing and fixing Suspension-clamp, for PCC Poles made of new MS flat size 65/6 sqmm. as per RESPO specifications.
Providing and fixing Dead end clamp size 95/50sq mm. for PCC Poles as per RESPO specifications.
Providing and fixing of T/F Lugs.
Constriction of plinth for installation of 250 KVA T/F of size 1.5/1.5/1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC Top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall.
Safely installation of New 250 KVA T/F on the plinth by private crain with proper alignment and Complete fitting including making connection and commissioning
Safely installation of New 100 KVA T/F on the double pole with Complete fitting including making connection and commissioning
Pipe Earthing of 250 KVA T/F (1 No body & 1 No. neutral earthing) by boring & fixing of G.I pipe 1½ Dia (Jindal Class B) and connecting with G.I. Strip of size 40x4 mm and G.I wire at bottom of G.I pipe to the T/F providing of required charcoal & salt in the pipe.
Choping of tree branehes touching the 11 KV/LT lines
SHIV CONTRACTOR (BID ID -4790139)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .