Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC lowest bid | |
| 2 | L2₹10.3 L+₹38,347 (3.86%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹11.0 L+₹1.0 L (10.4%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹11,200
Closing Date
6 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal
PROVN OF STORE ROOM WITH PARTITION WITH ALLIED WORKS AT DSCC BHOPAL
2020_MES_375733_2
8567/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dronachal
Please refer tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Dronachal
₹11,200
Yes
28 Jan 2021
9 Sept 2020
12 Oct 2020
9 Sept 2020
6 Oct 2020
22 Sept 2020
60 days
Amount
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out hard/dense soil complete all as specified and directed
ditto as item No 01 above but exc 1.5 m but not exc 3.0 m complete all as specified and directed.
Excavation over area n.exc. 1.5 m deep in hard/dense soil and getting out complete.
Removing excavated soil material to a distance exc 250m but n exc 500 m and deposited where directed at a level n exc 1.5 m above the starting point outside MOD land complete all as specified and directed
M&L for PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L RCC M-25 (design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass concrete complete all as specified and directed.
M&L RCC M-25 (design mix)using 20 mm graded stone aggregate as in Col, Pillars post and struts etc complete all as specified and directed
M&L RCC M-25 (design mix) using 20 mm graded stone aggregate as in beams, cantilever, bressummers, lintel over 1.5m span etc complete all as specified and directed
M&L RCC M-25 (design mix)using 20 mm graded stone aggregate as on Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and directed
M&L for Use and waste of formwork to sides of concrete foundation, footing,base of column ,raft beams , sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified and directed.
M&L for Use and waste of formwork to soffits of suspended slabs such as roof slabs ,floor slabs ,landing and similar work not exc 200mm thick (Horizontal or sloping) to rough finish surface of concrete flat. complete all as specified and directed
M&L for Use and waste of formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat. complete all as specified and directed
M&L for Use and waste of formwork to sides of pillars, posts ,struts piers ,columns and stanchion to rough finish surface of concrete square ,rectangular or polygonal. complete all as specified and directed
M&L for Use and waste of formwork to edges of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat. complete all as specified and directed
M&L for TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed
Ditto as item No 16 here-in-bofore but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar1:6. complete all as specified and directed
M&L for rendering 15mm thick cement plaster on other than fair face of brickwork surfaces of wall in (internal) CM 1:6 surfaces finish fair and even with using extra cement with complete all as specified and directed
M&L for rendering 15mm thick on fair faces of brick work or on concrete surfaces of wall in (external) CM 1:4 surfaces finish fair and even with in two layers with water proofing compound @ 3% by weight of cement complete all as specified and directed. (water proofing compound payed seperately)
M&L for rendering 5mm thick on fair faces of brick work or on concrete surfaces of ceiling in CM 1:4 surfaces finish fair and even with using extra cement complete all as specified and directed.
supply only Integral waterproofing compound complete all as specified and directed.
M&L for Preparing of new plaster surface and applying three coat of white wash on newly plaster surface of ceiling including 3 mm thick wall care putty. complete all as specified and directed
M&L, preparation of newly prepaired surface of wall and applying two coat of exterior weather proof water base emulsion paint over a coat of primer of same make on walls including 3 mm thick wall care putty all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coat of oil bound distemper over a coat of primer of same make on walls including 3 mm thick wall care putty all as specified and directed.
M&L for 75 mm thick palin cement concrete B-2, 1:2:4 (using 40 mm graded crushed stone aggregate) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note :- The plinth protection shall be laid in apnels and length of each panel shall not be more than 2.00 mtr all as directed 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item complete all as specified and directed.
M&L for providing 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base of flooring complete all as directed.
M&L for cement concrete type B0 (1:2:4) using 12.5 mm graded aggregate 25 mm thick as in floor for receiving screed bed complete all as specified and directed
S&F in 4.8 mm thick sheet glass pan area exc 0.50 Sqm in each pan with rubber bedding galzing clips and necessary fittings complete all as specified and directed.
S&F 12 mm thick prelaminated particle board exterior grade,prelaminated both sides with decorative choice lamination fixed in glazing for doors complete all as specified.
S&F in 5mm thick ACP sheet both sides laminated with aluminium sheet of same colour fixed in glazing in doors or windows with clips and necessary fittings complete all as specified and directed
M&L RCC M-25 (design mix) using 20 mm graded stone aggregate as in chajja complete all as specified and directed.
use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed
M&L for approved earth filling in floor or pavings, laid in layers n exc 15 cm thick spread , levelled and rammed including watering complete all as specified and directed:
M&L for Light shade vitrified ceramic tiles 10 mm thick (square/rectangular) polished,area of each tiles not exceding 0.36 Sqm in floors etc set and jointed in cement slurry and pointed in white or coloured cement to match and laid over 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
All as per item No 35 above but laid on vertical surface as in dado/ skirting complete all as specified.
S&F in door or window frame or for partition of any description with aluminum sections, coloured powder coating not less than 50micron, and fixing in positions including all necessary cleats, lugs, beading, and jointing arrangements, complete all specified & directed.
S & F in Anodised aluminium door shutters aluminium section coloured powder coating not less than 50micron,weighing not less than 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
M&L for APP based polymeric membrane minmum weighing 3 Kg/Sqm and minmum 3 mm thick reinforced with polyster non wove fabric ( wt not less than 150 gms/sqm) including priming of surface by forced application with hot blower application and including overlapping at joints complete all as specified and directed.
M&L applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per Sqm including cleaning surfaces for applying APP roof membrane complete all as specifed and directed.
S&F Cement concrete tiles 20cm x 20cm x 20mm thick, m a c h i n e pressed; set jointed and pointed in neat cement slurry as in roof coveing including screed bed 20 mm thick in CM 1:4 in floors, and cut and polished complete all as specified and directed.
M&L for fixed in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5 m clear spn, cill, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, mass filling / levelling coarse as in rood padding coarse and the like including weathering, slightly rounded or chandered angles and throating, as directed complete all as specified and directed.
M&L Broken glass coping on top of walls in CM 1:3 and fixing in freshly prepared coping complete all as specififed and directed.
S&F Cut-lath nails (cut-tacks), exc 25 mm long but n exc 40mm and 2.0 to 2.40 mm in dia fixed (minimum 2 kg pr Sqm ) with broken glass on top of wall complete all as specififed and directed.
S&F Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk) forming holes, with bolting, rivetting attachment Fe 410-W(Gde-E- 250)quality-A complete all as specified.
S&F in Steel work in tubular trusses including special shaped washer, required nuts and bolts fixtures etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed
S&f 6mm thick hollow Polycarbonate corrugated roof sheet(ISI marked) fixed with self driving screws with washer roof and joined two sheets will be filled with silicon weather proof sealant and covered with aluminium strip of 50mm x 3mm top and bottom complete all as specified and directed.
Supply only MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 5cm and not exceeding 10cm long and dia complete all speciified and directed.
M&L for two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth. Complete all as specifed and directed.
M&L for point wiring with and including 1.5 sqmm (nominall area) PVC insulated multi-stranded copper conductor FRLS in and including PVC conduit with ISI marked 20/30 mm size or as required at site including with ints fittings and fixture such as tees, bends, elbows and junction boxes all moduler type surface mounting etc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor conected to main earthing and common earth terminal complete all as specified and directed. Note:- Modular PVC surface mounting boxes and for mounting wsitch, socket with modular farme plate and cover complete all as specified and directed.
one light point controlled by one switch.
one 3 pin socket outlet 5 Amps on independent board
one 3 pin socket outlet on same board.
M&L for point wiring complete 2.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 650/1100 volts drawn through non metallic rigid PVC casing capping including necessaryaccessories like bends tees and elbows etc fixed on wall / ceiling including sunken type pressed steel terminal boes of suitable size with plastic laminated white / coloured top sheet cover 2 mm thick including 1.5 Sqmm FRLS PVC insulated copper green wire for earth wire complete for 3/5 in 15 Amps switch socket combination complete all as directed by Engineer-in-Charge.
S&F only DB SPN 240 Volts 200 Amps rates bus bar having 4 way double door shutters.
S&F MCB SPN 240 Volts of capacity 40 Amps complete all as specified & directed by Engineer-in-Charge.
S&F MCB SP 240 Volts of capacity 5 to 30 Amps complete all as specified & directed by Engineer-in-Charge.
S&F sub main wireing 4 Sqmm with two runs of 4 Sqmm single core multi stranded copper conductor and one run of 2.5 Sqmm in PVC conduit including all fitting fixed on wall / ceiling including 1.5 Sqmm PVC insulated copper earth wire connected to earth complete all as specified & directed by Engineer-in-Charge.
Supply & fix LED tube light along with fixture, 22 W
S&F switch piano type 5 Amps 250 volts single pole one way
S&F socket outlet 5 pin flush 6 Amps multi Pin 2/3 pin.
S&F ceiling rose surface bakelite 65 x 60 mm, 3 terminal complete all as specified and directed.
S&F switch socket flush type 250 volts 5 Amps multipurpose complete all as specified & directed by Engineer-in-Charge.
S&F switch socket outlet type 250 V 5/15 Amps multipurpose.
S&F LED street ight 70/75 W IP 65 with 40 mm dia light grade bracket length of 1.2 meter
RAJPATI CONSTRUCTION
Vee kay construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .