Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹9,600
Closing Date
1 Sept 2026, 10:55 am4d left
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Annual Maintenance Estimate of the E.I work at Main Building of Bankura Sammalani Medical College and Hospital under BSMC and H Electrical Section-II, PWDte.--------Miscellaneous Electrical Installation and Allied Works at Various Location of Bank
2026_WBPWD_5019560_1
WBPWDTE/AE/BMCESD/NIQ-25/Q of 2026-2027
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,600
Yes
20 Aug 2026
20 Aug 2026
3 Sept 2026
20 Aug 2026
1 Sept 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismentling the existing damage , defective & non functioning Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC. and the agency have to submit the dismantled Electrical Installations at the BSMC&H Electrical sub division by their own arrangements with full list of items. | 1 | Item | - | - |
| 2 | Dismentaling , Shifting & Re-installation, Testing, and Commissioning of 5 TR capacity concealed type Split Air Conditioner Machine.
(i) No. of ODU- 01 Nos.
(ii) Rated Cooling capacity of ODU: Upto 90,000 BTU / Hr. or Higher
(iii) Rated Power Supply of ODU: 400V,50Hz, 3Ph.
(iv) Compressor type- Twin Rotary/ Scroll
(v) No. of IDU- 02 Nos.
[For Old Bank ] | 1 | Set | - | - |
| 3 | Dismentaling , Shifting ,Installation , Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of suitable size bracket for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC. [For HOD Peaditric + OPD Dermatology OPD building & G&O Building] | 5 | Set | - | - |
| 4 | Dismantling of existing 1.5/2.0 Tr Window /Split Type AC Machine Complete with Indoor/Outdoor units ,disconnecting electrical connections ,dismanteling carefully by using companys own tools & tackles and carrying the dismantaled unit to BMC Electrical Subdivision store as directed by Enineer-In-Charge. | 6 | Each | - | - |
| 5 | Overhauling of 1.5/2.0 Tr single phase Air Condition machine includes complete inspection , cleaning , servicing and testing of the unit to restore efficient and reliable operation .The work involves dismantaling of indoor and outdoor units , through cleaning of coils and filter , checking electrical components compressor performance ,refrigerant level ,replacement of worn-out or faulty parts if required and re-installation .After overhauling , the air conditioner is tested to ensure proper cooling ,safety and smooth operation for uninterrupted service.[For Principal Quater +EOT+G&O USG Room ] | 6 | Set | - | - |
| 6 | Supply & laying of Suction line 5/8" Cu.Pipe With 9 mm thick Nitrile Insulation & Liquid Line 3/8" Cu. Pipe with 9 mm thick nitrile insulation for 7.5 Tr Concealed Split AC Machine. [ For Old Blood bank +Principal Quater + HOD Peaditric + OPD Dermatology] | 63 | Mtr | - | - |
| 7 | Charges of Refrigerant R-22 | 23 | Kg | - | - |
| 7.01 | R-410 | 11 | Kg | - | - |
| 8 | Supply and Laying Copper Control Cabling from Condensing Unit to control panel (Make:Gloster/ Polycab 4 core 2.5 sq.mm communication cable [For 3 Phase Blood Bank Machine ] | 46 | Mtr | - | - |
| 9 | 3 core 2.5 sq mm communication cable [ For Single Phase Machine -- Principal Quater + HOD Peaditric + OPD Dermatology+Brun unit +EOT ] | 50 | Mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_5092146.xls
BOQ • 0.32 MB
2911.pdf
Additional Documents • 0.13 MB
OID.pdf
Other Document • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].