| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.6 L+₹69,847 (1.56%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹47.0 L+₹2.1 L (4.76%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹47.6 L+₹2.7 L (5.95%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹48.6 L+₹3.7 L (8.22%)Rejected-Finance | L5 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹85,600
Closing Date
24 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineer Services Air Force Stn Adampur 144103
ADDN / ALTN TO CERTAIN TECH ACCN IN TECH AREA AT AF STN ADAMPUR
2023_MES_588190_1
GE/AF/ADM-01/2023-24
Open Tender
Civil Works
Item Rate
180 days
Tech area AF STn Adampur
Refer NIT and Tender Docuents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹85,600
Yes
18 May 2023
5 Apr 2023
25 Apr 2023
5 Apr 2023
24 Apr 2023
18 Apr 2023
6 Apr 2023 - 17 Apr 2023
Amount
BUILDING WORKS
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete, all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Removing excavated spoil to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Removing excavated spoil to a distance exceeding 2 km but not exceeding 5 km and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
PCC type B-2 (1:2:4), using 40 mm graded stone aggregates in surface channels and drains complete all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates in surface channels and drains complete all as specified.
Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified.
Precast RCC type B-1 (1:2:4), using 20 mm graded stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar (1:4) complete all as specified.
Reinforced cement concrete, design mix M-25 using 20 mm graded stone aggregates in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
Reinforced cement concrete, design mix M-25 using 20 mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Reinforced cement concrete, design mix M-25 using 20 mm graded stone aggregates as beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified.
Reinforced cement concrete, design mix M-25 using 20 mm graded stone aggregates in columns, pillars, piers, posts and struts complete all as specified.
Extra for forming fair finished drain or channel 30-45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified.
Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Cutting openings, through brick walls, built in cement mortar for door, window & other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective bk wk for under-pinning, including providing, fixing & removing shoring, cleaning & stacking bricks, removing surplus serviceable bricks, hardcore, etc., to store & rubbish not exc. 50 m, complete all as specified.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified.
Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforced with mild steel square tube, suppling & fixing in opening, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded wood grain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and wood grain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all all as specified.
Solid PVC wall lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame, PVC strip etc fixing as wall panelling, complete all as specified.
5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame as per specification SSR part-I complete all as specified.
Insulated PVC 25 mm thick wall lining, consisting of PVC insulated panels having expanded polystyrene (EPS) stuck to 2 mm thick plain colour PVC sheet duly fitted into the wall, complete all as specified.
Aluminium anodised barrel tower bolt of extruded section 150 mm long, ISI marked, complete all as specified.
Stainless steel butt hinges 100 mm long, ISI marked, complete all as specified.
Extruded aluminium anodised handles fabricated type with plate 150 mm long, ISI marked complete all as specified.
Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 6-8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.
Mild steel rolled sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to grade Fe-290-Gde E-165, complete all as specified.
Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., as door frames, and hanging; also fastening and fixing confirming to grade Fe-290-Gde E-165, complete all as specified.
Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and se-curing runners with holdfasts and brackets, complete all as specified.
Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as in-dicated, with thickness of lath as 1 mm, complete: gear operated type with bevel gear box and crank handle, all as specified.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws comlete all as specified.
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
Powder coated aluminium door shutters with styles & rails made out of section size 83-85 mm x 44-45 mm (wall thickness not less than 2 mm) , powder coated alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
Powder coated aluminium window and ventilator shutters side hung type with styles & rails made out of section size 47-48 mm x 44-45 mm (wall thickness not less than 1.58 mm), powder coated alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
Powder coated aluminium grill type DG-117 including necessary 'U' clip & screws etc as per manufacturers instructions, complete all as specified.
Plain tinted sheet glass, 5-6 mm thick, ordinary quality duly sticked with solar control reflective type film, having thickness not less than 25 micron and fixed air tight with neoprene packing & almn glazing clips, for aluminium sections, complete all as specified. NOTE: Almn glazing clips & neoprene packing will be measured & paid for under respective item of aluminium door/windows/partition.
Powder coated GI snap grid frame work of size 605mm x 605mm for false ceiling complete with acessories all as specified and shown on serial page No.186 of MES Schedule Part-II.
4 mm thick E-board, multipurpose, decorative type fixed in grid frme work ceilings as panels, complete all as specified.
Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified.
Water Proofing Treatment to RCC roofs all as specified in Particular Specification clause 11.2,complete.
Aluminium composite panel sheet 4-5 mm thick, of shade approved by GE, cut to shape and fixed in position as almn door shutter panels/partition, complete all as specified.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
50 mm thick, cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate, finished even & fair, as infloors, complete all as specified.
75 mm thick, cement concrete type B-2, 1:2:4 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 10mm thick rendering in cement mortar (1:4), complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified.
Endura vitrified paving coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but not exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified.
Vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc. 0.25 Sq.m but not exc 0.36 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified.
Factory made PCC chequered tiles, ISI (IS:13801) marked, with grey cement & pigment, 22-25 mm thick, of size 250 mm x 250 mm, in floors, over & including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete, all as specified.
80 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50 mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete.
Rendering 5 mm thick on RCC or similar surfaces, finished even and smooth on ceilings in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified.
Supply only water proofing compound, ISI marked, complete all as specified.
Prepration of old plasterd ceiling surfaces of any description and applying two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd ceiling surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty in two coats & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of height not exc 7.50 metre and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer in disruptive/camouflaging pattern of four shades complete all as specified.
Complete removal of existing treatment of any description of height not exc 7.50 metre and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer in disruptive/camouflaging pattern of four shades complete all as specified.
Complete removal of existing treatment of any description of height exc 7.50 metre but not exc 15 metre and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer in disruptive/camouflaging pattern of four shades complete all as specified. NOTE: RGB value of four shades of disruptive/camouflaging pattern shall be all as shown on Drg No. GE/SK-1/19 sheet 1/2 & 2/2.
Plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane incl hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surroundings; glazing with putty or fixed with beads complete all as specified.
Sound proof double layer 8mm thick clear toughened glass with 12mm air gap / vaccume pressure (8mm CTG + 12mm air gap+8mm) with clear visibiity and fixed in aluminium frame with necessary fixing material as approved by GE including hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surroundings; glazing with putty or fixed with beads complete all as specified. Note:- Measurement of doublr layer will be considered as single side.
Applying one coat (finishing coat) of synthetic enamel paint, including preparation of old painted wood and wood based surfaces of any description not other wise described over 10cm width or girth and complete all as specified.
Applying one coat (finishing coat) of synthetic enamel paint, including preparation of old painted steel or iron surfaces surfaces of any description not other wise described over 10cm width or girth and complete all as specified.
Two coats of synthetic enamel paint over a coat of red oxide primer including peparation of new steel & iron surfaces of any description not other wise described over 10cm width or girth, complete all as specified.
500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP complete all as specified.
1000 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP complete all as specified.
Steel tubes 15 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Steel tubes 25 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, (For Urinal flush cock) complete all as speciifed.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6510 or equivalent make mentioned in Appendix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6508 or equivalent make mentioned in Appendix 'B'.
Centre hole basin mixer, cast copper alloy chromium plated, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: PRAYAG Cat No. 6550 or equivalent make mentioned in Appendix 'B'.'.
Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, including PVC seat & cover and stainless steel body Jet spray (L-bend) with1.50 metre long braded tube tube, IN REPAIRS, complete all as specified MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix 'B'.
Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, complete all as specified. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appendix 'B'
Vitreous China half stall Urinal pot, white, size 345 x 320 x 560 mm, with & including cast copper alloy, half or full threaded chromium plated waste coupling suitable for & including 32 mm size PVC waste/discharge pipe, rag bolts, CP brass lever type flush cock 25 mm size, IN REPAIRS, complete. MAKE OF URINAL: PRAYAG Cat No. 4998 or equivalent make mentioned in Appendix 'B'.
Stainless steel (SS-204) sink made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 460mm x 405mm x 203 mm with bowl size 405mmx 354mm complete. MAKE: PRAYAG Cat No.1316D or equivalent make mentioned in Appendix 'B'.
Steel plate rack made of stainless steel 0.65mm thick over all size 786 x 914 x 254 mm fixed to wall with suitaable size stainless screws & PVC rawl plugs complete all as specified. MAKE: PRAYAG Cat No.P-448 or equivalent make mentioned in Appendix 'B'.
Health faust with 1 metre SS tube & hook complete. MAKE OF URINAL: PRAYAG Cat No. BEA-97 or equivalent make mentioned in Appendix 'B'.
PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, complete. MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appendix 'B'
Brass chromium plated towel rail 500-600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix 'B'.
Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-15S or equivalent make mentioned in Appendix 'B'.
Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints, complete all as specified.
PVC connections 15 mm size of length 600 mm with PTMT nuts, complete all as specified.
uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, laid in trenches, under floors or fixed to walls as SWR pipes, complete all as specified.
uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, laid in trenches, under floors or fixed to walls as SWR pipes, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, complete all as specified,
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, complete all as specified,
uPVC/PVC vent cowl 75 mm external dia, complete all as specified.
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, including jointing with solvent cement in PCC type B-1 (1:2:4), complete all as specified,
uPVC gully trap 125/110 mm, suitable for uPVC soil waste discharge pipes 75 mm ext dia, including jointing with solvent cement in PCC type B-1 (1:2:4), complete all as specified,
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified.
Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.
Cutting into existing manholes for connecting new drains, of 150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
INT ELECTRIFICATION WORKS
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4).
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: 2 runs of 4 Sq. mm along with one run of 4 Sq. mm single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified. NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.suitable for surface and flush mounting, complete all as specified.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.
Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Exhaust fan 300 mm sweep, heavy duty with louvers fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up complete from ceiling rose or connector to fan, complete all as specified.
Hi wall mounted split type air conditioner 5 star rated with minimum ISEER 4.5 inverter type and EER 3.2, of capacity 4500K.cal ( 1.5 Ton), electric driven single phase 230 Volt 50 hz AC supply indoor & outdoor unit complete with cordless remote & mounted on brackets for outdoor unit including provision of waste water pipe from indoor unit to outside the building complete all as specified .
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 3KVA with mounting bracket with time delay relay. complete all as specified .
DEMOLITION & DISMANTLING WORKS
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified.
Taking down framed steel doors, window, gates, partitions etc area not exc 4 Sq. m each complete all as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning for refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories)
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
M/S GURBACHAN SINGH
siddharthenterprises
M/s Sahib and Company
B S ENTERPRISES
PRATHAM TRADERS
AAR KAY BEE ENTERPRISES
J.K & Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .