| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1ST₹7.6 LAccepted-AOC 28 DESH PRAN SASMAL ROAD CIT MARKET TOLLYGUNGE BLOCK B 31 KOLKATA KOLKATA KOLKATA 700033 | KOLKATA | WEST BENGAL | 700033 | ₹7.6 L | 1ST | Accepted-AOC L1 |
| 2 | 2ND₹7.7 LRejected-Finance | ₹7.7 L | 2ND | Rejected-Finance L2 |
| 3 | 3RD₹7.8 LRejected-Finance 104 SARAT GHOSH GARD EN ROAD CAL 31 700031 | KOLKATA | WEST BENGAL | 700031 | ₹7.8 L | 3RD | Rejected-Finance L3 |
Tender Value
₹7.6 L
EMD Value
₹15,300
Closing Date
10 Jan 2026, 2:00 pmClosed
D.G.(WS)
OFFICE OF THE DIRECTOR GENERAL WATER SUPPLY DEPARTMENT 5, S N BANERJEE ROAD KOLKATA-700013
REPLACEMENT OF A TUBEWELL SIZE 150X100 MM AT DR. A. P. J. ABDUL KALAM PARK IN WARD NO. 118, BR. XIII
2025_KMC_971909_1
KMC/WS/PBDT/2025-26/39
Open Tender
Miscellaneous Works
30 days
PODDARNAGAR BIG DIA TW UNIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹15,300
13 Mar 2026
20 Dec 2025
13 Jan 2026
20 Dec 2025
10 Jan 2026
20 Dec 2025
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre). (i) First 50 metre Note: (i) For item no. 2, measurement will be taken below G.L. taking G.L. as zero for payment. (ii) For item no. 1 & 2 for bored depth where no lowering of pipe is involved the corresponding rates would be reduced by 30%.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre). (ii) Next 50 metre Note: (i) For item no. 2, measurement will be taken below G.L. taking G.L. as zero for payment. (ii) For item no. 1 & 2 for bored depth where no lowering of pipe is involved the corresponding rates would be reduced by 30%.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre). (iii) Next 50 metre Note: (i) For item no. 2, measurement will be taken below G.L. taking G.L. as zero for payment. (ii) For item no. 1 & 2 for bored depth where no lowering of pipe is involved the corresponding rates would be reduced by 30%.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (c) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 300 mm dia.(upto 50 metre.) (iv) Rest 100 metre Note: (i) For item no. 2, measurement will be taken below G.L. taking G.L. as zero for payment. (ii) For item no. 1 & 2 for bored depth where no lowering of pipe is involved the corresponding rates would be reduced by 30%.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL(a) Original Works 20 Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works 23 Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works 29 Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works 22 Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
PLUMBING WORKS (A)-(II) G.I. PIPE WORKS AND FITTINGS 19(III) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (L) Reducing Socket (mm X mm) (v) 150 X 100
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works 6 Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (iv) 100 mm dia.
PLUMBING WORKS (A)-(II) G.I. PIPE WORKS AND FITTINGS 19(III) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes(Dia) (i)100 mm
PLUMBING WORKS (A)-(II) G.I. PIPE WORKS AND FITTINGS 19(III) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes(Dia) (k)150 mm
PLUMBING WORKS (A)-(II) G.I. PIPE WORKS AND FITTINGS 19(III) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (J) Threaded End Cap (Dia) (k) 150 mm
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works 24 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.
PLUMBING WORKS (A)-(II) G.I. PIPE WORKS AND FITTINGS 19(III) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes(Dia) (f)50 mm
SECTION(A) PLUMBING WORKS (A)-(VI) TUBE WELL (a) Original Works 27 Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
SUPPLY AND DELIVERY OF(5 HP, 5 STAGE, MINIMUM BORE DIA 150MM, HEAD 38M, DISCHARGE 28M^3/HR) CLEAR WATER VERTICAL WET TYPE SUBMERSIBLE PUMP SUITABLE FOR BORE WELL CONFORMING TO IS: 8034 (AND AS AMENDED THEREAFTER) WITH STANDARD MOC FOR POTABLE CLEAR COLD WATER AND BEE 3 STAR RATED CAPABLE OF DISCHARGING NOTED M^3/HR AGAINST HEAD OF WATER COLUMN. THE PUMP SHALL BE DIRECTLY COUPLED WITH A CONTINUOUS RATED 2-POLE SUITABLE WET TYPE VERTICAL SQUIREL CAGE INDUCTION MOTOR CONFORMING TO IS: 9283 (AND AS AMENDED THEREAFTER), SUITABLE FOR OPERATION IN AC THREE PHASES 415 V, 50 HZ(CATEGORY B MOTOR). SOR PHE NOVEMBER 2021
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC
UNSKILLED CATEGORY (AS PER MUNICIPAL SECRETARY'S CIRCULAR NO. 06 OF 2025-26 DATED 24.07.2025)
SEMI-SKILLED CATEGORY (AS PER MUNICIPAL SECRETARY'S CIRCULAR NO. 06 OF 2025-26 DATED 24.07.2025)
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.91 MB
BOQ_2364736.xls
BOQ • 0.26 MB
techbid.pdf
Tender Documents • 0.46 MB
Download all tender documents and submit your bid