| 1 | 1₹30.9 LAccepted-AOC RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 1 | Accepted-AOC Being lowest and reasonable rates | |
| 2 | 2₹31.2 L+₹26,480 (0.86%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 2 | Rejected-Finance Not being lowest tenderer | |
| 3 | 3₹35.0 L+₹4.1 L (13.2%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | 3 | Rejected-Finance Not being lowest tenderer | |
| 4 | 4₹35.2 L+₹4.3 L (13.8%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 4 | Rejected-Finance Not being lowest tenderer | |
| 5 | 5₹35.4 L+₹4.4 L (14.4%)Rejected-Finance CB 288 RING ROAD NARAINA NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | 5 | Rejected-Finance Not being lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹86,200
Closing Date
5 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE U Delhi Cantt 110010
HQ CWE U Delhi Cantt 110010
PROVN OF ADDITIONAL 3 PHASE POWER SUPPLY FOR INTERIM,SATELLITE HUB AND TP STUDIO AT 5 SIGNAL GP UNDER GE(U) ELECT SUPPLY DELHI CANTT-10
2021_MES_439200_1
89036/D-04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Delhi cantt
as per tender
6 documents required · 6 mandatory
₹500
GE U Electric Supply
₹86,200
Yes
30 Jul 2021
29 Apr 2021
7 Jun 2021
29 Apr 2021
5 Jun 2021
29 May 2021
60 days
Amount
Disconnecting of all HT/LT connection electrically and machanically of outdoor transformers 100 KVA capacity, taking up/down from plinth carefully including transportation to MES yard, complete all as directed.
Supply & install ,testing and commissioning of transformer step down, outdoor type copper wound 11KV/433 Volts (at no load) AC 3 phase 50 Hz 500 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to 10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changergear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked and shall comprise of the following :- (Contd/--)
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete. (b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out single core 1000 sqmm, LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (c ) Conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Lifting ligs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.
(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes, specific resistance at 27 Degree celsius Ohm-om 500 x 10 the power12, water content 50 PPM, Dielectric dissipation factor (tan Deta at 90 degree celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03, Inter facial tension N/M at 27 Degree celsius - 0.04, flash point 140 Degree celsius and sluge 0.1 % by weight. (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Tranformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with energy Effeciency level - II. (Contd/--)
(n) Oil temperator indicator , winding temperature indicator, marshlig box single window, double flit buchhols relay with alarm and trip contact including connection to existing RMU relay with PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm 10 core 1100 volts grade. NOTE:- The transformer is required to be placed on existing platform of 100 KVA transformer, the rates for which are deemed to be included in quoted rates.
Supply and installation of Servo voltage stabilizer for automatic operation, three phase, of capacity 500 KVA , 50 Hz Automatic controlling/Regulating of voltage comprising Auto Transformer, Buck & Boost Transformer, copper wound with new filter and Dehydrated Transformer oil (As per IS : 335), servo motor, Auto controlled solid state control cuircut, naturally oil cooled, outdoor type and designed for three phase input voltage range between 340 Volts to 450 Volts and output voltage stabilized at 415 Volts + 1% with accuracy + 2.5% and speed of correction 8 volts per second including other fittings and accessories as Voltmeter(0-300) to read input/output voltage per phase, mains/low/high limit indicators, manual increase/decrease push switch, auto/manual mode control switch and output adjustment etc including :- (a) Electronic control circuit. (b) Low voltage cutoff. (c ) High voltage cutoff. (d) Single phase preventor. (Contd/..)
(e) Time delay. (f) Toggle switch provided to by pass. (g) Servo by pass switch. (h) Over load and short circuit Trip facility(MCCB). (j) No voltage cutoff NOTE:-The construction of platform for installation of servo voltage stablizer 500 KVA as per recommendation of OEM including excavation and earth work at site are deemed to be included in the quoted rates complete.
Supply, Laying, connecting, testing and commissioning of LT cable of PVC sheathed XLPE armoured aluminium conductor 1100 V graded 1000 sqmm single core complete all as specified and directed.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 5 above but of size 185 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 5 above but of size 120 Sqmm 3.5 core complete all as specified and directed.
M&L for plate Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level with alternate layer of common salf and charcoal dust mixed & packed 150 mm thick homogeneous layer all around the GI earth plate and connected to galvanized earth strip 32 x 4 mm by means of bolts and nuts checknuts and washers of galvanized iron electric arc welding all joints all as specified and shown in electrical plate No 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode 20 mm dia pipe for watering complete all as specified and directed and testing on completion.
Supply, installing, testing and commissioning LT Panel outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (Contd/--)
LT panel mounted on 02 Nos, Brick pillars including excavation and earth work (PCC 1:2:4) type B1, brick work 1:4 and 15mm plaster of cement (1:6). The LT Panel should proper spacing to accommodate all accessories, cable connection with suitable size of lugs /thimbles and cable glands comprising of the following :- (a) Horizontal/vertical bus bar of 1000Amp (4 strips) of Copper. (b) LT switch gear 440 Volts 3 phase 4 wire 50 Hz complete with Air Circuit Breaker, adjustable load protection, no-volt release with microprocessor release EDO with neccessory CTs, mertes and cable boxes of rating 800 Amps - 01 No (Incoming). (c ) MCCB 3 pole 400 Amp 415 Volts at 50 Hz breaking capacity 50 KA microprocesser release type - 02 Nos (Outgoing). (d) MCCB 3 pole 200 Amp 415 Volts at 50 Hz breaking capacity 36 KA microprocesser release type - 01 Nos (Outgoing). (e) MCCB 3 pole 160 Amp 415 Volts at 50 Hz breaking capacity 36 KA microprocesser release type - 01 Nos (Outgoing). (Contd/--)
(iii) Maximum continuous current (Imax) - 10 A • Rated Frequency (variation) - 50Hz (±5%) • Power consumption: (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature. • Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height • Display in the event of Power Failure: Internal battery back-up for LCD display • Communication port:
Supply, installing, testing and commissioning LT Panel outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 50 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (Contd/..)
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer -in-charge.
M&L for returing filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil all specified and directed
M&L for removing of excavated material n exc. 50m and depostiting where directed at a level n exc. 1.5m in soils all specified and directed
M & L for sand as in sand cushioning to underground PVC cable including punning down of sand layer all specified and directed.
Supply and laying burnt brick sub class 'B' of size 23cm x 11.5cm x 7.5 cm locally available laid in length of brick perpendicular to the length of cable all specified and directed
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe upto 100 mm bore and making good both ends all specified and directed
S&F GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of size 100 mm dia all specified and directed
M&L for PCC in foundation filling and mass concrete, type D2 (1:4:8) using 40 mm grded aggregate for foundation of pole complete all as specified
M& L for PCC type B1 (1:2:4) using 20 mm graded stone aggregate for pedestal of poles including use and waste of formwork complete all as specified
mayur enterprises
Ridhi engineers and builders
Vijay Electricals
Electro Tech Systems
V r traders
Buddham Builders
DS CONSTRUCTION
Vijaypower Generators Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .