Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC Lowest Rate | |
| 2 | L2₹2.7 L+₹1,215 (0.45%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹2.7 L+₹2,647 (0.98%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L3 | Rejected-Finance Higher than L1 | |
| 4 | L4₹2.8 L+₹4,924 (1.82%)Rejected-Finance ALAMPUR NODAKHALI | L4 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹5,510
Closing Date
4 Nov 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer
Raghunathpur, Jhargram.
WBPHE/EE/JMD/NIeT 14_13 OF 2022-2023
2022_PHED_410307_13
WBPHE/EE/JMD/NIeT 14 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
30 days
Jhargram
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,510
Yes
24 Jan 2023
28 Sept 2022
9 Nov 2022
28 Sept 2022
4 Nov 2022
29 Sept 2022
120 days
Amount
Supply and delivery of following materials at site:- Automatically controlled plunger type Chlorinator dosing pump with flow rate 100 LPH and maximum pressure of 10 kg/ CM2 with built in relief valve & diaphragm rupture indicator, pressure gauge, pressure switch, base plate, flexible coupling guard for pump & motor, foundation bolt, suction and discharge flange and with storage tank of dosing solution of 100 Ltr. Capacity and the prime mover to be coupled with pump of 0.5 H.P. 3 Phase, 1450 RPM squirrel cage TEFC induction motor, Motor will be IE2/ IE3. [Make of Machine: As per attached vendor lists of PHED.] Pump Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments. (Motor Make- CGL/KEC/ABB/Any approved make)
415 V, PDB cum MCC timer based panel having 2 mm thick CRCA sheet with IP 54 protection consist of 2 nos. of DOL (Direct Online) starter, 1 no. of welding feeder, 1 no. of lighting feeder conforming to IS-8623 with suitable Bus bar, Digital Voltmeter, Ammeter, Contactor delay timer, MCB etc. (Drawing & Bill of material shall be approved by E.I.C)
1.1 KV Grade 415 V, 4 core 10 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 1988 with latest amendments as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
63 Amps, 415 V, 4 pole ICTPN (Iron Claded Triple Pole Neutral) main switch in sheet steel enclosure having rewireable type fuse grip. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
6-32 Amp,10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, "C" characteristics. (6 Amp- 1 no., 10 Amp - 2nos., 16 Amp - 1no.) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
6 way SP&N Double Door horizontal Distribution Board conforming to IS 13032 & IS 8623 and IP42/43. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
LED street light luminarie housing IP 66 LM6-HPDC Housing, aerodynamically designed with better thermal management/ Potted driver is to be provided.The luminaire and housing should be from the same manufacturer (cat no- BRP409 LED CW 045 MR FG S1 PSU GR, LUMEN O/P-4500,System Efficacy greater than 100 lumen/watt) Make-Philips.The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip along with type test Certificate.Respectively the luminaire manufacturer should have an in house NABL Accredited testing facility.
380 mm 4 blades 900 rpm heavy duty Exhaust fan as per direction of EIC (Make-Havells,Model:Turbo force SP.)
PVC moulded chair without arm. (Make:- Nilkamal/Supreme/Cello)
PVC moulded table of 850 x 850x 725 mm size. (Make:- Nilkamal/Supreme/Cello)
63 Amp, 240/415 V Porcelain fuse unit (Base & Bridge) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019 with latest amendments.
Hard wooden board (450 mm X 304.8 mmx 2 mm thick)
Installation of the supplied items: Installation of above mentioned panel (as in item no. 2) on suitable position wall by supplying & fitting-fixing of required nos. of angle, fastners, nut-bolts, washers etc. with necessary earthing arrangements by G.I. strip/wire and mending damaged as per entire satisfaction of EIC.
Installation & commissioning of the above supplied chlorinator (as in item no. 1) with all accessories, PVC tank and drawing of power line as per I.E. rules by supplying of necessary wire and continuous earthing. This include the cost of all necessary CC foundation (at least 200 mm) with concrete mixture (Sand, cement, stone chips) and neat cement finishing by supplying of all required materials and testing the entire set as per direction of E.I.C. N.B - 1)T.C & G.C of pump motor needed. 2) All works should be carried out as per relevant & latest IS code.
Fitting-fixing of the supplied wooden board (as in item no. 12) at suitable position on wall with fitting-fixing of supplied 100 Amp Porcelain fuse units (as in item no. 11) on the board by supplying and fitting-fixing of required nos. of nuts-bolts-washers etc. all complete as per direction of E.I.C
Fitting-fixing of the distribution board (as in item no. 6) on flat /angle iron frame at desired position on wall of pump house with supplying & fitting-fixing of required nos. of nuts, bolts, washers etc. with necessary earthing arrangement from nearest earth grid by G.I. wire/ strip all complete as per direction E.I.C. This includes the cost of fitting-fixing of the Isolator & MCBs within the DB including necessary power connections by 2.5 mm2 FRLSH copper wire (Havells /KEI/Finolex/Gloster/polycab/other approved make) all complete.
Laying of cable (as in item no. 3) on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C.
Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of cable (as in item no. 3) all complete as per direction of E.I.C.
Finishing the end of cable (as in item no. 3) by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials all complete as per direction of E.I.C.
Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 Hz SPN/DP MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point-2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket,switch, indicator- 1 no. each, Exhaust fan point-1 no with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed cut-out to SPN/DP MCB within DB through 20 mm PVC casing capping (precision make) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light sets PHILIPS Astra Line, one no. bulk head (Endura WT202W LED6S NW PSU S2 PC), one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency).
S&F of 3" dia 1.5 mt minipole with baseplate to be fixed on rooftop incl. S&F of 1.5 mtr long arm bracket (removable type) incl. CC muffing (450X450X600) with neat cement finish & painting incl.S&F 200x150x100 mm 16 SWG CI loop box including neccessery power connection by 3X22/.03 (1.5 Sqmm) (2 nos. Phase and Neutral and 1 no ECC) FRLS-H pvc insulated & unsheated copper wire (approved make) in 20 mm size PVC rigid conduit FRLS-H (precision Make) including necy. fittings as required as per direction of EIC. (for 12m length @ 102/mtr.) as directed by EIC.
a)Excavation of soil for installation of Earth Electrode and filling & ramming. (b) For Morrum Soil
(b) Earthing with 50 mm diameter G.I. pipe 3.64 mm thick x 3Mtr. (10ft.) long and 1 x 4 SWG G.I. wire (4Mtr.long) 13 mm diameter x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F of 15mm diameter G.I. pipe protection (1 Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed. i) For soft soil by ISI Medium GI pipe.
(c) Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
(d) Connecting the equipments body to earth busbar including S&F 20 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc.
(e) Extra for treatment of soil by salt and charcoal coke for pipe electrode.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.Length of busbar is 0.5 mtr.
Fixing only exhaust fan(as in item no. 8) after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter.(38 cm)
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x62 mm long) 38 cm Exhaust fan (15")
Add: 18% GST
Add: 1% CESS
WEST BENGAL ENGINEERING CO.
DAS ENTERPRISE
S. P. CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .