Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.1 LAccepted-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L-1 | Accepted-AOC Lowest bidder for the subject work. | |
| 2 | L-2₹12.9 L+₹40,520 (3.25%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | L-3₹14.9 L+₹2.4 L (19.1%)Rejected-Finance | L-3 | Rejected-Finance other than the lowest bidder |
| Sl No | Description | Qty | Unit | M/S JAINENDRA KUMAR JAIN L1 | M/S SHIVA TRADERS L2 | M/s VIKAS TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting existing incoming & outgoing connections and inspection, servicing, testing, checking and calibration healthiness of entire HT 33 kV, 800 Amps, 25 kA VCB outdoor type including cleaning, greasing of all mechanical parts of VCB and checking smooth operation manually and motorised with remote panel of VCB for tripping and closing, checking of CTs, PTs, all internal wiring as per site requirement, calibration of VCB and components and to maintain desired insulation level of each phase for smooth operation and test reports of all panels complete all as specified and as directed including the followings: -
(a) Cleaning of Vacuum Circuit Breaker with CRC-226.
(b) To check the condition of SIC contacts.
(c) Checking condition and alignment of jaw contact.
(d) Checking and proper tightening of hardware.
(e) Checking of proper closing/ open of all poles.
(f) Checking of breaker tripping through push button.
(g) Checking and adjusting gap between hylem sheet and side plate.
(h) Checking motor operation in case of EDO.
(i) Checking auxiliary contacts continuity proper change over.
(j) Checking of presence if circlips.
(k) Checking IR between phase to phase (VCB closed condition).
(l) Checking IR between phase to earth (VCB closed condition).
(m) Checking IR between phase to earth (VCB open condition).
(n) Cleaning and providing lubricants on movable mechanical parts.
(o) Testing of relays through secondary injections.
(p) Tripping of VCB through Buchholz relay/ OTI/WTI if required.
(q) Testing of CTs and PT.(s) Testing of contact resistance of VCBs Note: -(i) Spare parts excluding wiring shall be measured & paid separately. (ii) Servicing shall be carried out by authorised rep of VCB manufacturer. | 1 | Each | 45,000 ₹45,000 | 20,000 ₹20,000 | 12,000 ₹12,000 Lowest |
| 2.00 | M&L for repairs to motor charging mechanism by opening of 33KV, upto 800A, 25 KA circuit breaker by authorised Engineer complete all as specified and directed. | 1 | Each Job | 13,000 ₹13,000 | 20,000 ₹20,000 | 5,000 ₹5,000 Lowest |
| 3.00 | S&F in repalcement of tripping and closing coil for 33 KV VCB outdoor type as per existing complete all as specfied and directed. | 1 | Each | 11,500 ₹11,500 | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest |
| 4.00 | S&F in replacement of limit switch for VCB as per existing complete all as specified and directed. | 1 | Each | 7,000 ₹7,000 | 2,000 ₹2,000 Lowest | 2,500 ₹2,500 |
| 5.00 | Inspection, servicing, testing, checking and calibration of remote panel for HT 33 kV VCB, outdoor type including cleaning, checking internal wiring, tripping operation of earth fault and over current relays, transformer protection relays complete for smooth operation of panel by injecting artificial HT supply for checking tripping on earth fault and over current complete all as specified and as directed. (As mentioned in ser No. 1).The items listed below inclusive and provided.
a) Rewiring of DC connections
(b) Over current relay
(c) Indication Lamp
(d) Multifunction Meter
(e) AMP Meter
(f) Bold Meter
(g)TNC SWITCH
(h) ANCTER
(j)CTS Relay
(k) Bazer 30 volt
(l)WTI, UTI
(m) Indicator
(n)Door handle
(o)Copper control Wire 2.5 & 1.5 sq.mm
(p)Natural Link
(q) MCV
(r) Rubber Packing ,holder with bulb 30 vol etc. other item | 1 | Each Job | 60,000 ₹60,000 | 50,000 ₹50,000 | 10,000 ₹10,000 Lowest |
| 6.00 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. | 126 | Cum | 330 ₹41,580 | 200 ₹25,200 Lowest | 250 ₹31,500 |
| 7.00 | Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed. | 1 | Cum | 450 ₹450 | 300 ₹300 Lowest | 400 ₹400 |
| 8.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. | 90 | Cum | 120 ₹10,800 | 30 ₹2,700 Lowest | 50 ₹4,500 |
| 9.00 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. | 38 | Cum | 130 ₹4,940 | 30 ₹1,140 Lowest | 100 ₹3,800 |
| 10.00 | Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. | 28 | Cum | 1,150 ₹32,200 Lowest | 1,200 ₹33,600 | 1,500 ₹42,000 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
4 Apr 2026, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
REPAIR/RENEWAL OF E/M INSTALLATIONS, H/T LINE AND ALLIED WK AT MIL STN DHANA UNDER AGE (I) DHANA
2026_MES_756503_1
84196/E8
Open Tender
Civil Works
Item Rate
180 days
Dhana
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Dhana
₹28,000
Yes
20 Apr 2026
16 Mar 2026
6 Apr 2026
16 Mar 2026
4 Apr 2026
30 Mar 2026
16 Mar 2026 - 30 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting existing incoming & outgoing connections and inspection, servicing, testing, checking and calibration healthiness of entire HT 33 kV, 800 Amps, 25 kA VCB outdoor type including cleaning, greasing of all mechanical parts of VCB and checking smooth operation manually and motorised with remote panel of VCB for tripping and closing, checking of CTs, PTs, all internal wiring as per site requirement, calibration of VCB and components and to maintain desired insulation level of each phase for smooth operation and test reports of all panels complete all as specified and as directed including the followings: -
(a) Cleaning of Vacuum Circuit Breaker with CRC-226.
(b) To check the condition of SIC contacts.
(c) Checking condition and alignment of jaw contact.
(d) Checking and proper tightening of hardware.
(e) Checking of proper closing/ open of all poles.
(f) Checking of breaker tripping through push button.
(g) Checking and adjusting gap between hylem sheet and side plate.
(h) Checking motor operation in case of EDO.
(i) Checking auxiliary contacts continuity proper change over.
(j) Checking of presence if circlips.
(k) Checking IR between phase to phase (VCB closed condition).
(l) Checking IR between phase to earth (VCB closed condition).
(m) Checking IR between phase to earth (VCB open condition).
(n) Cleaning and providing lubricants on movable mechanical parts.
(o) Testing of relays through secondary injections.
(p) Tripping of VCB through Buchholz relay/ OTI/WTI if required.
(q) Testing of CTs and PT.(s) Testing of contact resistance of VCBs Note: -(i) Spare parts excluding wiring shall be measured & paid separately. (ii) Servicing shall be carried out by authorised rep of VCB manufacturer. | 1 | Each | - | - |
| 2 | M&L for repairs to motor charging mechanism by opening of 33KV, upto 800A, 25 KA circuit breaker by authorised Engineer complete all as specified and directed. | 1 | Each Job | - | - |
| 3 | S&F in repalcement of tripping and closing coil for 33 KV VCB outdoor type as per existing complete all as specfied and directed. | 1 | Each | - | - |
| 4 | S&F in replacement of limit switch for VCB as per existing complete all as specified and directed. | 1 | Each | - | - |
| 5 | Inspection, servicing, testing, checking and calibration of remote panel for HT 33 kV VCB, outdoor type including cleaning, checking internal wiring, tripping operation of earth fault and over current relays, transformer protection relays complete for smooth operation of panel by injecting artificial HT supply for checking tripping on earth fault and over current complete all as specified and as directed. (As mentioned in ser No. 1).The items listed below inclusive and provided.
a) Rewiring of DC connections
(b) Over current relay
(c) Indication Lamp
(d) Multifunction Meter
(e) AMP Meter
(f) Bold Meter
(g)TNC SWITCH
(h) ANCTER
(j)CTS Relay
(k) Bazer 30 volt
(l)WTI, UTI
(m) Indicator
(n)Door handle
(o)Copper control Wire 2.5 & 1.5 sq.mm
(p)Natural Link
(q) MCV
(r) Rubber Packing ,holder with bulb 30 vol etc. other item | 1 | Each Job | - | - |
| 6 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. | 126 | Cum | - | - |
| 7 | Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed. | 1 | Cum | - | - |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. | 90 | Cum | - | - |
| 9 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. | 38 | Cum | - | - |
| 10 | Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. | 28 | Cum | - | - |
stage.html
html • 0.05 MB
technical_847386.pdf
techsummary_847386.pdf
finance_847386.pdf
BOQ Comparative Chart
xlsx
finsummary_847386.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_847386.xls
BOQ • 0.27 MB
84196TenderDocuments.pdf
Tender Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .