Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹17.8 L+₹89,131.50 (5.28%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.5 L+₹4.6 L (27.5%)Rejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹21.7 L+₹4.9 L (28.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹23.4 L+₹6.5 L (38.7%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Sept 2024, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1, Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-42/2024-25 REPAIR / MAINT OF DIESEL GENERATING SETS, SERVICE MAIN CABLE AT TECH AND DOMESTIC AREA, EARTHING AND OTHER MISC E/M WORKS AT AF STATION PALAM UNDER GE (AF) GURGAON NO 1.
2024_MES_665561_1
GE (AF) Gurgaon No 1/GUR-42/2024-25
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹70,000
Yes
16 Oct 2024
12 Jul 2024
7 Sept 2024
12 Jul 2024
5 Sept 2024
27 Jul 2024
Amount
A (Monthly) Check :
M&L for monthly Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance as directed.
Monthly Service : (a) Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid separately (c ) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in alternator terminal block (j) Checking of alternator carbon brush and connections in alternator (k) Checking and tighting of all connection in DC control wiring.
(l) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (m) Checking and recording oil pressure, water and oil temperature (n) Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (r) Checking of AMF panel, all electrical connections etc. (s) Checking of earthing resistance (t) Cleaning of vegetation around the DG set up to 1.5 mtr area.
400 KVA Capacity, Make : Kirloskar , Location : Tech Area Power House (Total 01 Nos)
200 KVA Capacity, Make : Cumins, , Location :16 BRD (01 Nos)
82.5 KVA Capacity, Make : Kirloskar, Location : OLD STP, New STP, LLLRW (Total-03 Nos)
62.5 KVA Capacity, Make : Kirloskar, Location : Booster Pump House (Total-01 Nos)
40 KVA Capacity, Make : Kirloskar, Location : Madhur Millan Pump House, L-2 Switch at Tech Power House-(Total-02 Nos)
25 KVA Capacity, Make : Kirloskar, Location : Afnet Tech HQ Bldg, Domestic Power House, (Total -02 Nos)
B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier
Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :-
Repeat the activities of 'Á' Check (b) Replacement of of lubricant oil. (Note:- Lub Oil are Paid separately.) (c ) Replacing lubricant oil filter element with 'O' ring (d) Replacing fuel filter element (e) Replacing coolant. (f) Replacing Governor oil
Notes :B Check kit, coolant shall and Lubricant oil shall be measured and paid separately under relevant items
400 KVA Capacity, Make : Kirloskar , Location : Tech Area Power House (Total 01 Nos)
200 KVA Capacity, Make : Cumins, Location :16 BRD (01 Nos)
82.5 KVA Capacity, Make : Kirloskar Location : OLD STP, New STP, LLLRW (Total-03 Nos)
62.5 KVA Capacity, Make : Kirloskar,Location : Booster Pump House (Total-01 Nos)
40 KVA Capacity, Make : Kirloskar, , Location : Madhur Millan Pump House, L-2 Switch at Tech Power House-(Total-02 Nos)
25 KVA Capacity, Make : Kirloskar, Location : Afnet Tech HQ Bldg, Domestic Power House, (Total -02 Nos)
Supply only B check kit for DG set of following capacities ( Note : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element ) :-
400 KVA Capacity, Make : Kirloskar , , Location : Tech Area Power House (Total 01 Nos)
200 KVA Capacity, Make : Cumins, , Location :16 BRD (01 Nos)
82.5 KVA Capacity, Make : Kirloskar , Location : OLD STP, New STP, LLLRW (Total-03 Nos)
62.5 KVA Capacity, Make : Kirloskar, Location : Booster Pump House (Total-01 Nos)
40 KVA Capacity, Make : Kirloskar, , Location : Madhur Millan Pump House, L-2 Switch at Tech Power House-(Total-02 Nos)
25 KVA Capacity, Make : Kirloskar, , Location : Afnet Tech HQ Bldg, Domestic Power House, (Total -02 Nos)
Dismantling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning :
(a) 25 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 82.5 /100 KVA Capacity
(d) 200/250 KVA Capacity
(e) 400 KVA Capacity
Dismantling, removing the alternator /dynamo of from the engine of following capacity of DG Sets , opening up over hauling servicing, replcement of carbon brushes with holders, assembling back , refixing and testing for proper function.
(a) 25 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 82.5 /100 KVA Capacity
(d) 200/250 KVA Capacity
(e) 400 KVA Capacity
Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function :
(a) 25 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 82.5 /100 KVA Capacity
(d) 200/250 KVA Capacity
(e) 400 KVA Capacity
Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ serving, replacement of pim spiral, washers, Cup injector,retainer, Cup screw etc assembling calibiration, setting for proper function refixing and testing for:
(a) 25 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 82.5 /100 KVA Capacity
(d) 200/250 KVA Capacity
(e) 400 KVA Capacity
Disconnecting all the connections from alternator of DG Set of following Capacity removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing clening all the parts with thinner and varnishing completely with F class varnishing, applaying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed.
(a) 25 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 82.5 /100 KVA Capacity
(d) 200/250 KVA Capacity
(e) 400 KVA Capacity
M & L for replacement of defective spare parts of DG Sets of capacity 400 KVA, Make : Kirloskar, including connecting and testing all as specified and directed.
(a) Radiator Hose Pipe Set
(b) Air filter (inner & Outer)
(c) Water Pump assembly
(d) Turbocharger repair Kit
M & L for replacement of defective spare parts of DG Sets of capacity 200 KVA, Make : Cummins, Model ______________NTA-743-G including connecting and testing all as specified and directed.
(a) Air filter Inner
(b) Turbo charger repair Kit
(c )Water Pump Assembly
M & L for replacement of defective spare parts of DG Sets of capacity 82.5/100 KVA, including connecting and testing all as specified and directed.
(a) Air Filter
(b) V Belt
(c) Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 63 KVA, Model GIR 20OSL & NRF 225/2 Make :Greaves including connecting and testing all as specified and directed.
(a) Air filter
(b) V Belt
(c) Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 50/40 KVA,Type 4R 1040 Make :Kirlosker including connecting and testing all as specified and directed.
(a) Air filter
(b) V Belt
M & L for replacement of defective spare parts of DG Sets of capacity 25/30 KVA,Model- S 3804 & NB 200M Make :Greaves including connecting and testing all as specified and directed.
(a) Air filter
(b) V Belt
(c) Hose Pipe Set
M & L for replacement of Door Hinges of various capacity of DG Set including taking down the old door hinges complete all as directed.
Supply and fixing battery lead with negative & Positive brass terminals of suitable size with 3 m length of each lead all as directed
M & L for complete checking of AMF panel,finding the fault, servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations all as directed. (Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule.)
Repair to AMF Panels 40 to 82.5 capacity of DG set dismantling/taking down of all electrical connection from unserviceable AMF panel to carry out following repairs :- (a) Replacement of unserviceable microprocessor auto main failure relay 400 volt AC 3 phase 4 wire system having following parameter :- (i) Display of RYB phase voltage. (ii) Display of generating voltage. (iii) Display of generator frequency. (iv) Display of main frequency. (v) Display of battery voltage. (vi) Display of single phase current. (vii) Display of generator run hours Make:- C&S/Hitech or equivalent. (b) Replacement of digital multifunctional meter of size 96x96mm having following parameter: (i) Voltage, ampere and frequency (c) Replacement of digital energy meter 3 phase of size 96X96mm. (d) Replacement of safety control relay for cranking-01 Nos. (e) Replacement of burnt out control wiring for panel with suitable size of lugs. (f ) Replacement of auto/manual switch
M&L for replacement of UNSV contactor AC operated 4 pole 415 volts suitable for the following capacity of DG set
(a) DG set 400 KVA
(b) DG set 200 KVA
(c) DG set 82.5 KVA
(d) DG set 63 KVA
(e) DG set 40 KVA
(f) DG set 25 KVA
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 400/200 KVA
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 82.5/62.5 KVA
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 40/25 KVA
S&F in replacement of window glass of canopy of capacity 400 KVA
S&F in replacement of window glass of canopy of capacity 82.5 KVA
S&F in replacement of window glass of canopy of capacity 25/40/62.5 KVA
S&F in replacement of heat proof asbestos rope 12 mm to 20 mm dia on engine exhaust pipe including dismantling of worn out asbestos rope and minor welding tightening in leakage of exhaust pipe complete all as directed confirming to IS specifications of fire proof/flame proof
Taking out old unserviceable battery charger from the following DG sets replacement with the following battery charger of suitable capacity and checking the terminals including petroleum jelly and spray cleaning and getting test certificate to produce Engr-in-charge for the following capacities of DG sets all as specified and directed.
(a) Battery charger 24 volts 20 Amps capacity panel mounted suitable for 400 KVA DG set complete all as directed.
(b) Battery charger 24 volts 10 Amps capacity panel mounted suitable for 200/250/320 KVA DG set complete all as directed.
(c) Battery charger 12 volts 20 Amps capacity panel mounted suitable for 62.5/82.5 KVA DG set complete all as directed.
(d) Battery charger 12 volts 10 Amps capacity panel mounted suitable for 30/40/50/62.5 KVA DG set complete all as directed.
Supply only coolent, K cool super plus 50-50 Premix complete all as directed.
Supply only Battery water with electrolyte mix complete all as directed.
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil complete all as directed.
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged.
Material and labour for replacement of unserviceable battery 12 V, 150 AH with maintenance free battery 12 Volt initially charged.
Material and labour for replacement of unserviceable battery 12 V, 90 AH with maintenance free battery 12 Volt initially charged.
S&F single phase preventor SPPR type SDz5, SPPR + Timer, 415 volts, 50 Hz, suitable for 3 phase DG Panel. Make : L&T Cat No XM81809OOOO or SEIMENS / BCH
S&F Electronic timers type ST100 , 415 volts, 50 Hz, suitable for 3 phase DG Panel. Make : L&T Cat No ST80328OOOO or equivalent out of make specified in list of make.
S&F DG Set 250/200/400 KVA Controller Dia, AVR, Start Stop Relay, wireing & Modification complete testing all as specified
M & L for supply, installation and commissioning of AVR for 82.5 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge
M & L for supply, installation and commissioning of AVR for 40/62.5 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge
M & L for supply, installation and commissioning of AVR for 25 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge
M & L for supply, fixing 4 Pole contactor 415 V AC, Amps rating 500, 415/240 V coil supply voltage, Model MCX 33, all as directed by Engineer-in-Charge
Supply and fixing of digital VAF + PF meter, Cl 1in square in size of 96mm x 96mm cross-section for DG sets suiatble for DG set upto 400 KVA, complete all as specified and directed.
Supply and fixing of DC Ammeter 0-30Amps of square in size of 96mm x 96mm cross-section, for DG sets suiatble for DG set upto 82.5 KVA, complete all as specified and directed.
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 82.4 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing of 'under/over voltage relay, single phase, 240 volts', (set of 3 for each phase in one panel) for DG sets of capacity upto 82.5KVA complete all as specified and directed by engineer-in-charge. Make: Teknika or equivalent out of make specified in list of make .
Supply and fixing of battery voltage relay 12/24 VDC suiatble for DG set upto 82.5 KVA, complete all as specified and directed.
Supply and fixing Three element overcurent and earth fault relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing frequency relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing engine start relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing speed relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing of Fuse (HRC type) 400 amps, for DG sets of capacity upto 125 KVA complete all as specified and directed. Make: L&T/ABB/Havells
Supply and fixing LED lamp of any colour (Red, yellow, green and blue) suitable for 12/24 v DC & AC for DG sets of capacity upto 125 KVA, complete all as specified and directed.
Supply and fixing 100/125 Amp, 415 Volts,4 pole, 50 Hz Power contactor of coil voltage 240 Volts, including spring operated add-on block and spring operated locking block along with spread suitable to bear current upto 350 Amps complete all as specified and directed.
Same as item no- 98, but of 63 Amp, 415 Volts,3 pole, 50 Hz Power contactor, spreader suitable to bear current upto 175 Amps complete all as specified and directed.
Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location including disconnection of existing electric incomming and outgoing cable and dismantling of PCC platform and make good with existing surface complete all as directed by the Engr-in-Charge.
Supply and fix in repair the AMF panel suitable for 250 KVA DG set factory made out of CRCA steel 16 SWG sheet floor mounting type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitably casketed to form dust and vermin proof. The panel would be powder coated minimum thickness of 50 microns, stove enameled paint finished after elaborate pre treatment to form a long lasting characteristic. The control panel will be complete in all respects with fuses, wiring and labels etc. The following will be incorporated in the AMF panel :-
(a) Multi-functional meter digital (Amp meter+ volt meter +Power factor+ KW+ KWH) -01 No (b) Alternator voltage monitor- 01 No (c) Main voltage monitor -01 No (d) Ammeter DG Analog -01 No (e) Voltage DG Analog -01 No, (f) MCCB 400 A, 25 KA for main supply -01 Nos, Havell's Cat No CM98401OOROOG, (g) MCCB 400 A, 25 kA for DG supply -01 Nos, Havell's Cat No CM98401OOROOG, (h) Main power contactor three pole-01 No , LT Cat No CS94144, (j) DG power contactor three pole- 01 No, LT Cat No CS94144, (k) Indicator lamp(RYB) - 01 set, (l) MCB (for control circuit - 10 Nos, (m) Auxiliary contactor -02 Nos, (n) Automatic battery 24 Volt charge -01 No , (o) Terminal O/L relay -01 No, (p) Terminals (for control cable) -06 Nos, (q) One set of copper bus bar of suitable capacity, (r) On load changeover 400 Amps capacity 04 pole-02 Nos.
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :-
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: Tech HQ)
M&L for colour coding of earthing pit cover and indication plate with rod with the following colour:- a) Red for chemical earth pit. b) Yellow for conventional earth pit. c)The numbering/marking of earth pit will be in capital black colour and is to be done as directed by Engineer -in- Charge.
M& L For industrial salt for earthing pit recharging complete all as directed by Engineer in charge
M & L for testing of earth resistance value of existing earthing pits once in a month with digital type earth tester at different locations of 13 BRD/16 BRD area up to the entire satisfaction of AF personnel & submitting the earth result all as directed. Note : Testing of all earth pits will be carried out on monthly basis and the same will be measured in presence of JE E/M and as directed.
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for laying of coarse aggregate(broken stone boulders) 40mm size in continuous bed of thickness 20mm and soft ramming to consolidate the aggregate to form a compact layer of aggregate around Earth pits and carefully demercating the surrounding in length by breadth, to facilitate percolation of rainwater rendering the surface where aggregate are laid, safe for operation during rainly season by naturally facilitating a insulating surface complete all as specified and directed.
Taking up old serviceable/unserviceable UG cable from trench for replacement , repair and re-laying or re-routing of size 50 Sqmm to 70 Sqmm complete all as specified and directed.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade with cross sectional area of the following size 70 Sqmm complete all as specified and directed.
Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection and' for stacking for bricks around the earth pits including civil work complete all as specified and directed.
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc all as specified and as directed.
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and directed.
M&L for sand filling in trenches for cushioning of cable complete all as specified and directed. Note:- Compacted / punned thickness be considred for the purpose of payment.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and as directed for foundation of stay, laying of cable etc. complete all as specified and directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed.
Supply and laying 40 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground complete all as specified and as directed.
S&F Rolled sections Fe 410-W (Gde- E- 250) quality- as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion
Earthing complete with copper earth plate electrode 60 cm x 60cmx 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to copper strips 20x3 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion
M&L for spray painting to LT panel board complete from inner and outer side with one coat of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces and welding work as required complete all as specified and directed including disconnection of supply from main comlete all as specified and directed. (approximate 8 sq mtr of each panel board ) Make - Asian paints /Berger Paints/Neroac Paints
M & L for welding of Panel door inner and outer and MCCB doors from front and back with necessary hinges & locking arrangements including properly disconnection of old unserviceable parts, MS sheet and angle irom complete & locking arrangements including replacement of followings (Note MS Sheet and angle iron will be measured and paid separated.
Supply and fix in replacement of MS sheet duly powder coated for enclosing the feeder pillar box of any size inclding taking down old rusted MS sheet complete all as specified and directed.
Supply and fix in replacement of MS Angle irom of size 50x50x50x6 and 40x40x6 mm sheet duly painted for bracing the sheet and also give the structure for the feeder of any size inclding taking down old rusted MS angle complete all as specified and directed.
Supply and fix in repair exterior rated BIS registered decorative LED Post Top luminaires. Luminaire should have system wattage of 72W (+/-5%), with system lumen output of minimum 8100 lumen with all LED ON, system efficacy of 110lms/w or more and operating voltage of 100-277V AC. Offered with color temperature (CCT) of 3000K with CRI > 80 and dedicated optics for each LED (PC lens) to ensure better uniformity of light distribution. Fixture should have step layered top enclosure in spun Aluminium minimum thickness of 1.2 mm designed to suit urban landscape and Lower spun aluminium of minimum thickness of 1.5 mm with Diameter not exceeding 570 mm, should be UV protected pure polyester powder coated grey after phosphochromate treatment. It should be Pressure Die Casting heat sink for heat dissipation and clear polycarbonate cover offering IK09 (Impact Resistance) with good transmission factor, and LED lifetime of L70B50 @ 50000 hours at 50°C, LED make should be of ceramic base of Nichea, Osram, Cree, Lumiled only.
The light fixture should have Operating temperature of 50 °C. Product is offered with IP 66 protection for serviceable LED Compartment and IP66 protection for Control Gear compartment with tool free access. Fixture should have diameter of 560 mm and height not more than 450 mm, weighing about 8.5kg with tolerance (+/- 5%). It should have built-in potted electronic LED driver with APFC, (SMPS based constant current supply), PF > 0.95, THD < 10%, Open Circuit Protection, over Voltage protection, Surge Voltage built in 4kV and External Surge protection up-to 10kV (DM/CM) & other safety test as per IS 15885 Part-2/Sec 13. Suitable for pole arm mounting with ID of Ø41mm with 3 nos. SS Hex bolt M8X25 screws. Make Havells Cat No EROSPT72WLED730PSYMTOPC or equivallent of bajaj/philips/Crompton/Hallonix
Supply of Havells make Single overhang circular decorative arms of 1 .5 mtr length one side, suitable to be mounted on Pole of 4 mtr - 9 mtr height. The Decorative arm should be made out of M.S. round tubular Pipe sections of 48mm Diameter attached to a pipe of 76mm dia to support suspended mounting of the LED Drop Down Post Top. The circular arm should be properly welded to the pipe by means of 3 segments of 29mm diameter (as shown in the reference drawing). A decorative Cast Iron embellishment knob at the top and designer element with 10mm square rod on the arm for aesthetics addition is required. The whole arm should be painted in pure polyester Paint in approved color shade of Pole. The Decorative arm to be approved by Engineer in Charge & Architect. Orbit Plus S Round Arm for Poleor equivallent of bajaj/philips/Crompton/Hallonix
Supply of 5-Meter-high Pole (lower section - 0.6 mtr, remaining M.S Pipe -4.4 mtr), having lower section OD 140 mm and top section 76mm diameter and Made out of GI pipe as per IS 1239. Round Mild steel plate of dimension 290 mm dia X 12 mm thick, should be joined with the pole at the bottom through welded joints, with 4 no. circular holes of dia 20mm at PCD 225mm suitable for M12 bolts. The pole must have an ornamental decorative casting at Bottom (Casting height 175mm/ lower dia 325mm) and middle casting (height 256mm and dia 2.7mm) with floral design patterns as shown in drawing. The two casting rings in the middle section (casting height 25mm/ Outer dia 116mm) as show in the reference drawing. The pole shall have window cutting of 300 mm x 100 mm weatherproof flush door & locking arrangement for housing of the pole to accommodate electrical accessories (Bakelite plate and connector) for power supply connection.
The window cover is fitted with allen screws to the pole and is to be provided in bottom section of pole. The body of the pole shall be machined and polished properly to give it a smooth surface as per IS 2629 and IS2633. The pole shall have decorative casting at the top of the shaft. The decorative pole shall be duly pre-treated and painted UV resistant coating in approved color shade. The Pole & the cast iron embellishments should be machined & polished properly to get the smooth finish. The coating should have a DFT of 80-90microns. Entire unit shall be given an extensive three Stage treatment with PU based etch primer, Zinc phosphate primer and Poly Urethane paint of approved color & prescribed for such surfaces to make it absolutely rust and corrosion proof, as well as giving it a pleasing appearance. Make Havells Cat No EROSPOLET01035M or equivallent of bajaj/philips/Crompton/Hallonix
Notes:- (a) The amount of Rs. 106196/- against Schedule of Credit on Page No. 124 & 125 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) As contract is maintenance nature the site shall be handed over in pieces as per site availability from users.
Sumit Enterprises (BID ID -3078797)
BRIJ MOHAN LAL AND CO. (BID ID -3087270)
M/S Delhi Engineering Co. (BID ID -3086793)
M/S Anand Enterprises (BID ID -3075390)
M/s Prakash Enterprises (BID ID -3085674)
J.P. Enterprises (BID ID -3085603)
Surjit and Sons (BID ID -3081537)
Ridhi engineers and builders (BID ID -3086948)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .