| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | ₹25.3 L | L1 | Accepted-AOC L1 idder |
| 2 | L2₹34.3 LRejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | ₹34.3 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹35.4 LRejected-Finance | ₹35.4 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹36.1 LRejected-Finance | ₹36.1 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹39.1 LRejected-Finance | ₹39.1 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | CHINAR CONSTRUCTION TRADERS L4 | M/s Nasir Rasool Dar L3 | M/S Noor Mohammad Shalla L5 | M/S RATHER CONSTRUCTION CO L2 | M/S UTA MOTORS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion. During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter, DC digital voltmeter, Potentiometer, DC, MCB for reverse battery protection. The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness, louvers for ventilation, gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specifications shall be as under:-
(a) Input working voltage-180 -270 Volts, (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1, (c) On load input power factor - > 0.8, (d) On load unit watt efficiencies-> 80% , (e) No load losses of complete charge-< 10% , (f) Ripple contents on the load (RMS)= 1% to 5% , (g) Over load - 110% for 30 minutes and will give visual indication for over load condition, (h) Boost charging - 2.4 V/Cell, (j) Float charging -2.15 V/Cell, (k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode, (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm, (m) Short circuit-MCB protecton provided. | 1 | Each | 40,000 ₹40,000 Lowest | 40,000 ₹40,000 Lowest | 1,20,000 ₹1,20,000 | 60,000 ₹60,000 | 2,00,000 ₹2,00,000 |
| 2.00 | M&L on load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed.
Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 3 here-in -after as supply only. | 6,500 | Litres | 10 ₹65,000 Lowest | 20 ₹1,30,000 | 10 ₹65,000 Lowest | 20 ₹1,30,000 | 15 ₹97,500 |
| 3.00 | Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required complete all as specified and directed. | 1,800 | Litres | 120 ₹2,16,000 Lowest | 200 ₹3,60,000 | 180 ₹3,24,000 | 180 ₹3,24,000 | 125 ₹2,25,000 |
| 4.00 | M&L servicing /testing of line circuit breaker, control panel including outdoor CT, PT and relays in control panel of outdoor Circuit Breaker of capacity 1250/800 Amps and rating 36 KV complete as details mentioned as under:-
(a) Details of servicing of breaker :-
(i) Checking of Closing/Tripping coil assembly, (ii) Adjustment of mechanism if required, (iii) Clean the circuit breaker to remove dust and dirt, (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts, (v) Check for rust,wear/tear, (vi) Checking of spring charge mechanism, (vii) Visual check for any deformation, (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc, (ix) Check for loosened connections, damaged lead wires, (x) Checking of control circuit & tighten the connections if any, (xi) Check close & trip coil, (xii) Replacement of Dashpot/shock absorbers, (xiii) Replacement of carbon brush of spring charging motor, (xiv) Cleaning of porcelain bushing, (xv) Checking of limit switch.
(b) The following test shall be carried out:-
(i) Primary Injection Test of outdoor CT / PT, (ii) Closing & Opening Timing Test for all three poles, (iii) IR Test with megger in open and closed condition, (iv) Contact resistance test for all three poles, (v) Closing coil resistance, (vi) Tripping coil resistance.
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-
(i) Over current and earth fault relay, (ii) Line diffrential relay.
(d) Testing of followig Aux relay:-
(i) DC Supply supervision relay, (ii) Trip Circuit suprvision relay, (iii) PT Fuse failure relay, (iv) Master trip relay, (v) Under voltage relay, (vi) Over voltage relay | 1 | Each Job | 7,000 ₹7,000 | 10,000 ₹10,000 | 4,000 ₹4,000 Lowest | 20,000 ₹20,000 | 10,000 ₹10,000 |
| 5.00 | M&L servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 630/800 Amps and rating 11 KV complete as details mentioned as under:-
(a) Details of servicing of breaker :-
(i) Adjustment of mechanism if required, (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth, (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts, (iv) Check for rust and wear, (v) Check Spring Tension and pitting of the Cluster Contacts,
(vi) Visual check for rust and deformation, (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc, (viii) Check for loosened connections, rust, damaged lead wires, (ix) Check whether the contacts are damaged by arcing, (x) Checking of control circuit & tighten the connections if any, (xi) Check close & trip coil, (xii) Checking of Jaw Contacts Conditions and repair/adjust, (xiii) Replace the jaw contacts,If required, (xiv) Applying of epoxy Paint for Support /Spouch insulator,CTs,PTs, and epoxy body at inside of VCB for improvment of resistance value, (xv) Replacement of Dashpot/shock absorbers, (xvi) Replacement of carbon brush of spring charging motor.
(b) The following test shall be carried out:-
(i) Primary Injection Test of CT / PT, (ii) Closing & Opening Timing Test for all three poles, (iii) IR Test with megger in open and closed condition, (iv) Contact resistance test for all three poles, (v) Closing coil resistance, (vi) Tripping coil resistance
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-
(i) Over current and earth fault relay.
(d) Testing of followig Aux relay.
(i) DC Supply supervision relay, (ii) Master trip relay. | 4 | Each job | 5,000 ₹20,000 Lowest | 10,000 ₹40,000 | 5,000 ₹20,000 Lowest | 15,000 ₹60,000 | 10,000 ₹40,000 |
| 6.00 | M&L topping up of / filling of SF-6 gas to achieve required gas pressure in 11 KV RMU and testing complete all as specified and directed. | 2 | kg | 4,000 ₹8,000 | 1,500 ₹3,000 Lowest | 8,000 ₹16,000 | 4,500 ₹9,000 | 2,000 ₹4,000 |
| 7.00 | S&F in replacement of closing coil assembly 50 volts DC of existing make ABB/CG for Outdoor breaker of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | 2,000 ₹2,000 | 1,000 ₹1,000 Lowest | 1,000 ₹1,000 Lowest | 5,500 ₹5,500 | 2,000 ₹2,000 |
| 8.00 | S&F in replacement of closing coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | 2,000 ₹2,000 | 1,000 ₹1,000 Lowest | 1,000 ₹1,000 Lowest | 5,500 ₹5,500 | 2,000 ₹2,000 |
| 9.00 | S&F in replacement of triping coil assembly 50 volts DC of existing make ABB/CG for Outdoor breaker of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | 2,000 ₹2,000 | 1,000 ₹1,000 Lowest | 1,000 ₹1,000 Lowest | 6,000 ₹6,000 | 2,000 ₹2,000 |
| 10.00 | S&F in replacement of tripping coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | 2,000 ₹2,000 | 1,000 ₹1,000 Lowest | 1,000 ₹1,000 Lowest | 6,000 ₹6,000 | 2,000 ₹2,000 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
11 Aug 2026, 6:00 pmClosed
Col Gaurav Kinha CWE
HQ 134 WE C/o 56 APO PIN-914134
Repair maint of 11 KV and 33 KV HT elect installations incl connected items such as transformers VCBs CT PT GOD DO fuses AVR cables etc at JAK LI RC under GE 970 EWS
2026_MES_778404_1
134WE-40(T)/2026-27
Open Tender
Civil Works - Others
Item Rate
180 days
GE 970 EWS
As per tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹93,000
24 Aug 2026
14 Jul 2026
13 Aug 2026
14 Jul 2026
11 Aug 2026
28 Jul 2026
14 Jul 2026 - 21 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion. During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter, DC digital voltmeter, Potentiometer, DC, MCB for reverse battery protection. The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness, louvers for ventilation, gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specifications shall be as under:-
(a) Input working voltage-180 -270 Volts, (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1, (c) On load input power factor - > 0.8, (d) On load unit watt efficiencies-> 80% , (e) No load losses of complete charge-< 10% , (f) Ripple contents on the load (RMS)= 1% to 5% , (g) Over load - 110% for 30 minutes and will give visual indication for over load condition, (h) Boost charging - 2.4 V/Cell, (j) Float charging -2.15 V/Cell, (k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode, (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm, (m) Short circuit-MCB protecton provided. | 1 | Each | - | - |
| 2 | M&L on load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed.
Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 3 here-in -after as supply only. | 6,500 | Litres | - | - |
| 3 | Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required complete all as specified and directed. | 1,800 | Litres | - | - |
| 4 | M&L servicing /testing of line circuit breaker, control panel including outdoor CT, PT and relays in control panel of outdoor SF 6 Gas Circuit Breaker of capacity 1250/800 Amps and rating 36 KV complete as details mentioned as under:-
(a) Details of servicing of breaker :-
(i) Checking of Closing/Tripping coil assembly, (ii) Adjustment of mechanism if required, (iii) Clean the circuit breaker to remove dust and dirt, (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts, (v) Check for rust,wear/tear, (vi) Checking of spring charge mechanism, (vii) Visual check for any deformation, (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc, (ix) Check for loosened connections, damaged lead wires, (x) Checking of control circuit & tighten the connections if any, (xi) Check close & trip coil, (xii) Replacement of Dashpot/shock absorbers, (xiii) Replacement of carbon brush of spring charging motor, (xiv) Cleaning of porcelain bushing, (xv) Checking of limit switch.
(b) The following test shall be carried out:-
(i) Primary Injection Test of outdoor CT / PT, (ii) Closing & Opening Timing Test for all three poles, (iii) IR Test with megger in open and closed condition, (iv) Contact resistance test for all three poles, (v) Closing coil resistance, (vi) Tripping coil resistance.
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-
(i) Over current and earth fault relay, (ii) Line diffrential relay.
(d) Testing of followig Aux relay:-
(i) DC Supply supervision relay, (ii) Trip Circuit suprvision relay, (ii) SF 6 gas pressure low, (iii) PT Fuse failure relay, (iv) Master trip relay, (v) Under voltage relay, (vi) Over voltage relay | 1 | Each Job | - | - |
| 5 | M&L servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 630/800 Amps and rating 11 KV complete as details mentioned as under:-
(a) Details of servicing of breaker :-
(i) Adjustment of mechanism if required, (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth, (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts, (iv) Check for rust and wear, (v) Check Spring Tension and pitting of the Cluster Contacts,
(vi) Visual check for rust and deformation, (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc, (viii) Check for loosened connections, rust, damaged lead wires, (ix) Check whether the contacts are damaged by arcing, (x) Checking of control circuit & tighten the connections if any, (xi) Check close & trip coil, (xii) Checking of Jaw Contacts Conditions and repair/adjust, (xiii) Replace the jaw contacts,If required, (xiv) Applying of epoxy Paint for Support /Spouch insulator,CTs,PTs, and epoxy body at inside of VCB for improvment of resistance value, (xv) Replacement of Dashpot/shock absorbers, (xvi) Replacement of carbon brush of spring charging motor.
(b) The following test shall be carried out:-
(i) Primary Injection Test of CT / PT, (ii) Closing & Opening Timing Test for all three poles, (iii) IR Test with megger in open and closed condition, (iv) Contact resistance test for all three poles, (v) Closing coil resistance, (vi) Tripping coil resistance
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-
(i) Over current and earth fault relay.
(d) Testing of followig Aux relay.
(i) DC Supply supervision relay, (ii) Master trip relay. | 4 | Each job | - | - |
| 6 | M&L topping up of / filling of SF-6 gas to achieve required gas pressure in 36 KV SF6 breaker and testing complete all as specified and directed. | 2 | kg | - | - |
| 7 | S&F in replacement of closing coil assembly 50 volts DC of existing make ABB/CG for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | - | - |
| 8 | S&F in replacement of closing coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | - | - |
| 9 | S&F in replacement of triping coil assembly 50 volts DC of existing make ABB/CG for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | - | - |
| 10 | S&F in replacement of tripping coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as specified and directed. | 1 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
PS40.pdf
Tender Documents • 1.11 MB
BOQ_871836.xls
BOQ • 8.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].