Loading…
Loading…
Tender Value
₹3.2 Cr
EMD Value
₹6.5 L
Closing Date
9 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully or substantially completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of work for this tender is -"Any Telecom work involving provision of MIS/ LAN/ WAN / Helpline / UTS/ PRS/ FOIS/Value added enquiry system/ Video enquiry system/ Data connectivity/Datacom equipment/ video conferencing / wireless communication/secured communication/Wi-Fi / Telecom work involving computer-based enquiry system".
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Two years warranty or latest guideline as per RDSO / Railway Board whichever is more.
A-Reconstruction/renovation & upgradation of facilities at booking office of stations under jurisdiction of Sr.DEN/2. B-Reconstruction/Improvement/ Renovation along with up-gradation of facilities at Booking offices under jurisdiction of Sr. DEN/3/HWH. C-Poliferation of ATVM over Howrah Division. D-Up-gradation of PA system at SYAE, TKPR & JSDG coaching depots .
SDSTE-ETN-BO-ATVM-26~ER
SDSTE-ETN-BO-ATVM-26
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹6.5 L
16 Sept 2026
16 Sept 2026
25 Sept 2026
231 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,41,12,068.38 | ||
| — | — | — | Above/ 407632.50 Below/P | ||
| Supply and laying of UTP Cat-6 LSZH cable"(a) Supply of UTP Cat-6 LSZH cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of 25mm PVC conduit pipe (medium grade ISI ) as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c ) Laying of CAT-6 through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site." | — | 4575.00 | — | — | |
| — | — | — | Above/ 80000.00 Below/P | ||
| Supply and laying of copper power cable"(a ) Supply of copper power cable 2.5 S.Q.mm 3 core. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of Power Cable as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site." | — | 1000.00 | — | — | |
| — | — | — | Above/ 165726.00 Below/P | ||
| Supply and Laying of LS cable"(a) Supply of LS cable. 2 Core 1.5 Sq.mm Steel Wire Armoured screened copper cable as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b ) Laying of LS cable through flexible PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary) as per direction of the Rly.Representative, including any fixing of cables/PVCpipe/PVC Casing on wall/shed with suitable clamps (theclamps and screws should be made of Stainless steel).All the fixing materials including Collar, bend, junctionetc. shall be supplied by the contractor. This alsoincludes transportation of cable, PVC Pipe, GI Pipe,HDPE Pipe etc. to the site." | — | 2700.00 | — | — | |
| — | — | — | Above/ 17146.20 Below/P | ||
| Splicing /termination of OFC as per site requirement | — | 85.00 | — | — | |
| — | — | — | Above/ 276104.82 Below/P | ||
| "Supply and Installation of 19"" rack mouted 24 Fiber management system and termination of OFC and Splicing of all the Fibers inside the Terminal Box with provision of taking out OFC as required. This includes supply of all Installation accessories including the pigtails with connector as per order of practice for installation and commissioning of Optical Fiber System as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 34.00 | — | — | |
| — | — | — | Above/ 788409.00 Below/P | ||
| Supply and Laying of HDPE pipe duct, 40/33 mm"(a) Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of armoured OFC cable/other Cables through duct in trenches and as advised by site engineer.Note:- (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fibre from end to end . (2) before & after laying of optical fibre cable through duct, continuity test from end to end of each fibre to be made by the contractor to ensure availability of all fibre duly certified by the site engineer if any." | — | 9.00 | — | — | |
| — | — | — | Above/ 149559.54 Below/P | ||
| "Supply and installation of Wall mounted 19"",9U Steel Rack with fan and 6 no sockets and accessories as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | — | — | Above/ 478438.82 Below/P | ||
| "Supply and installation of 2 Mbps SHDSL Modem as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | — | — | Above/ 2494563.51 Below/P | ||
| "Supply and installation of 4 Port Router as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | — | — | Above/ 1059853.44 Below/P | ||
| "Supply and installation of 4 port Lan extender as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 34.00 | — | — | |
| — | — | — | Above/ 195347.34 Below/P | ||
| "Supply and Installation of Media converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | — | — | Above/ 547150.78 Below/P | ||
| "Supply & installation of E1 to Ethernet converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | — | — | Above/ 1088223.38 Below/P | ||
| Supply and installation of 8 port PoE managed Network Switch with SFP module and patch cord"(a) Supply of 8 port PoE managed Network Switch with 10/100/1000 Mbps with Gigabit SFP Port as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(b) Supply of SFP Module Specification as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(c) Supply of Armoured SC-PC/ SC-LC/ FC-LC ( or as per requirement) Fibre Patch Cordas per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs ""(d) Supply of CAT6 Patch Cord as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs "(e) Installation of 8 Port Network Switch as per site requirement | — | 34.00 | — | — | |
| — | — | — | Above/ 4765.00 Below/P | ||
| "Supply and transportation of RJ45 Connector as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 500.00 | — | — | |
| — | — | — | Above/ 4684.86 Below/P | ||
| "Supply and Installation of Single Face RJ - 11 Input/Output Box. as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 34.00 | — | — | |
| — | — | — | Above/ 19954.26 Below/P | ||
| "Supply & installation of RJ-45 dual faceplate input-output module as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 34.00 | — | — | |
| — | — | — | Above/ 58461.64 Below/P | ||
| Supply and fixing of 20 Pair CT box"(a) Supply and fixing of 20 Pair CT box(Cable termination box Spec. No. IRS-TC/18-75 or latest. )Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 34.00 | — | — | |
| — | — | — | Above/ 12240.00 Below/P | ||
| Supply and fixing of 20 Pair CT box"(b) Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc. under supervision and instructions issued by Engr. In-charge of the work." | — | 1360.00 | — | — | |
| — | — | — | Above/ 470400.00 Below/P | ||
| "Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4"" of 1:2:4 concreting should be done. (b-1)Payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Inspection: Consignee." | — | 1920.00 | — | — | |
| — | — | — | Above/ 30000.00 Below/P | ||
| "Laying of S&T Cables of various cores/ pairs/ quads intrenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. Thisalso includes laying of cables in track crossings & roadcrossings. Item includes provision of labels of colored plasticadhesive tapes or any other identifiable material on each cableto give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying bycontractor under supervision of Railway Representative andhe will submit the meggering report of each testing). Length ofthe cable laid includes the length of the cable coiled fortermination purposes." | — | 6000.00 | — | — | |
| — | — | — | Above/ 405552.00 Below/P | ||
| "Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide onPlatform / Road / Hard rocky area. Refilling with earth levelingof trenches & restoring the original surface of trenches. Thesharp edges will be smoothened out in bottom of the chaseand will be leveled properly. In hard rocky ground area, cableswill be laid normally on layer of shifted earth of 0.05 mtrsthickness previously deposited at bottom of the trench andcables will be covered with layer of sand or shifted earth of 0.1mtr thickness. In case sharp edges of rocky ground cannot beprotected from shifted earth then GI/ CI /PVC /DWC/ HDPEpipes will be used, if numbers of cables are small. In casenumber of cables are large RCC duct will be used. In isolatedcases, it can be given smooth surface by using either masonrybricks or cement concrete. A row of bricks shall then be placedlength wise on the top and jointed with cement mortar andlayer of concrete with cement plaster shall be provided on topof the same.Note: This item in hard rocky area will be operated only wherenormal depth i.e.1.2 mtr is not possible and it will be decidedby site engineer/unit officer in-charge of work." | — | 816.00 | — | — | |
| — | — | — | Above/ 2886400.00 Below/P | ||
| "Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable.(a) Boring up to the length of 150 meters. Preparation of site forHorizontal Boring shall be carried out in presence ofRailway Representative." | — | 1600.00 | — | — | |
| — | — | — | Above/ 12800.00 Below/P | ||
| "Transportation of HDT machine with accessories includinghandling of stores materials, preparation of sites and boringfor placing of 110 mm dia HDPE PIPE for crossing of S&Tcables together a bridges/culverts, pucca road/crossing, boring trench shall be minimum 3 (three) meter below theriver bed and 1(one) meter below the track/road/pucca roadcrossing area. This includes supply of accessories forHDPE pipes, including, cost of fuel and all other items etc.which will be required for laying of cable through it. The workshall be executed as per instruction of site engineer. HDPEPIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactorshall provide all material required for boring and adequatenos. of labors for proper laying of cables into the bore. Cableshall be laid cautiously so that it should not get damage dueto rough handling & pressure on cable."(b) Laying of 6 quad/Signalling cable/Power Cable/OFC with nylonrope through 110 mm HDPE pipe and back filling of boringpit." | — | 1600.00 | — | — | |
| — | — | — | Above/ 113424.00 Below/P | ||
| "Digging of trench 1.2 Mtrs. deep from rail flange/ road leveland 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed." | — | 408.00 | — | — | |
| — | — | — | Above/ 1246250.00 Below/P | ||
| Cuting of he Platform surface (Tile/Slab/Mastic Pad/Concreat) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible. | — | 5000.00 | — | — | |
| — | — | — | Above/ 415633.00 Below/P | ||
| "Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | — | — | Above/ 369342.00 Below/P | ||
| Supply and installation of basic material to construct unit maintenance free earth"(a) Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL ,IEC to be produced. It consist of following:(a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no.(b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos.© Copper strip of 150x25x6 mm, to terminate earth rod = 1 no.(d) Copper strip of 300x25x6 mm (MEEB) = 1 no.(e) Copper strip of 150x25x6mm (SEEB) = 1 no.(ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter)(iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter )(iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB(v) Supply of copper lug sleeve for 3/16 cableInspection: RDSO""(b) Installation of Unit Maintenance Free Earth as supplied in above item.It includes( i ) Digging the earth to the required depth.(ii) Insertion of electrode.(iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor.(v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness.Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest.Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room.GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. This also includes inter-connecting of nearby existing earthing to make equipotentialNote: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee" | — | 17.00 | — | — | |
| — | — | — | Above/ 93636.00 Below/P | ||
| Supply & laying of 25x3 mm pure electrolytic copper tape and inter connection with the equipment with copper power wire"(a) Supply & laying of 25x3 mm pure electrolytic copper tape through suitable CLASS-'B' GI pipe for loop Earthing and bonding as per site requirement. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs " | — | 68.00 | — | — | |
| — | — | — | Above/ 21759.49 Below/P | ||
| "Supply and installation of 5 way AC Power extension Socket Complete set as per AnnexureInspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee if value of whole item in work less than 5 lakhs " | — | 17.00 | — | — | |
| — | 60.00 | — | — | ||
| "Disconnection & other to assist Telecoml | Day | Reconnection telecom works. Supervisor / | Equipments like Labours(Helper/Assistant) Other S&T work." |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureATVM.pdf
ATTACHMENT
CheckListAnnexItoVIIIUPDATED_1.pdf
ATTACHMENT
AnnexureIX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI_1.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCC-2022-Updated-25.09.24.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4_c.pdf Labour Cess
ATTACHMENT
GCCwithCorrectionSlips1to10.pdf
ATTACHMENT
TermsofPayment.pdf
ATTACHMENT
VICINITYOFUNDERGROUNDCABLE-
ATTACHMENT
OnlineBG.pdf
ATTACHMENT
ACS-11_compressed.pdf
ATTACHMENT
Updatedtenderdocument_RN.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4_c.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .