Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.8 L+₹1.9 L (5.30%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹39.3 L+₹4.3 L (12.3%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹39.8 L+₹4.8 L (13.8%)Rejected-Finance 25 KASHIPUR KASHIPUR BALLIA UTTAR PRADESH 277001 | BALLIA | UTTAR PRADESH | 277001 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical NO IN WLR QE JUN2021 HQ31CE |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
4 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
SPL REPAIR TO BLDG NO P-329 330, 331 369 T-24 AND SPL REPAIR TO SEWAGE LINE AT OAF UNDER GE 970 EWS
2021_MES_467703_2
GE 970 EWS-32/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹86,000
Yes
21 Jan 2022
14 Sept 2021
6 Oct 2021
14 Sept 2021
4 Oct 2021
19 Sept 2021
60 days
Amount
Demolition of brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Material & labour for broken stone (granite/basalt) hard core of gauge n.exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rolled, rammed to a true surface complete all as specified and directed.
Material & labour for PCC, 1:2:4, type B-1, using 20mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed finishing the surfaces even and smooth without using extra cement all as specified and directed.
Material & labour for PCC, 1:3:6, type C-1, using 20mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed finishing the surfaces even and smooth without using extra cement all as specified and directed.
Material & labour for 75 mm thick PCC, 1:3:6, type C-2, using 20mm graded stone aggregate as in sub base/plinth protection finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Material & labour for 100 mm thick PCC, 1:4:8, type D-2, using 20mm graded stone aggregate as in sub base flooring complete all as specified and directed.
Material & labour for old size Brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified and directed
Material & labour brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Taking down cement plaster on brick, stone or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Rendering plaster 15 mm thick in CM 1:4 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Rendering plaster 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Material & labour for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed in CM (1:4) including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises, complete all as specified or directed.
Material & labour for coloured glazed ceramic tiles in vertical surface 300mmX200mmX7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed in CM (1:3) including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises, complete all as specified or directed.
Material & labour for coloured glazed chequered cement concrete tiles with grey cement and no pigment of size 25cm x 25cm x 25mm thick, machine pressed set jointed and pointed in neat cement slurry in floors, laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises, complete all as specified or directed.
Supply and fixing in repair 15mm bore GI water tubing medium grade incl all fittings laid in floors complete all as specified and directed.
All as per item No 16 above but 20 mm bore ---ditto---
Material & labour for preparing new plastered or unplastered surface of wall and applying two coats of white wash complete all as specified and directed.
Material & labour for preparing old plastered or unplastered surface of wall and applying two coats of white wash complete all as specified and directed.
Material & labour for preparing new plastered or unplastered surface of wall and applying two coats of cement based paint complete all as specified and directed.
Material & labour for preparing old plastered or unplastered surface of wall and applying two coats of cement based paint complete all as specified and directed.
Material & labour for preparing old steel surface of any description and applying two coats of synthetic enamel paint complete all as specified and directed.
Material & labour for preparing old wooden surface of any description and applying two coats of synthetic enamel paint complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters and removing from site complete all as specified and directed.
Taking down chowkhats or frames n exc 1.5 sqm each with shutters and removing from site complete all as specified and directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tubes complete all as specified and directed.
Supply and fixing 30 mm thick factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site complete all as specified and directed
100 mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed .
150 mm extruded aluminium ally handles, fabricated type, anodised complete all as specified and directed.
150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
Supply and fixing in repair vitreous china squatting pan Orissa pattern water closet white of size 580x440 mm, with integral foot rests complete with P or S trap including with 10 ltr capacity PVC flushing cistern with flush pipe, PVC connection 450mm long etc. complete all as specified and directed
Supply and fixing in repair vitreous china wash down water closet pan (Pedestal pattern), white (EWC) with ‘P’ or ‘S’ trap, including connection to drain or outgoing pipe and 10 ltr capacity PVC flushing cistern, 15mm dia PVC connection 450mm long to flushing cistern/ sanitary fittings, inlet, outlet pipe connections, and plastic water closet seat cover, closed pattern with recessed bottom cover and mild steel chromium plated hinge complete all as specified and directed.
Supply & fixing in repair vitreous China wash hand basin white flat back, size 550mm x 400mm, cutting for and pinning in ends of brackets Including 32mm bore waste pipe, brass coupling, chromium plated brackets, restoring all connections complete all as specified.
Supply and fixing in repair 15 mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm-90gms) complete all as specified and directed.
Supply and fixing in repair 15 mm Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed.
Supply and fixing in repair swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) including Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour.(Minimum weight 40gms complete all as specified and directed.
Supply and fixing in repair 15 mm dia angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms), screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed.
Supply and fixing in repair stop valve of size 20mm dia stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm92gms) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fixing in repair PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
Supply & fixing in repair 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugations side lap bent to curve/shape, fixed with coach screws and washers or with L/J type hooks in roofs, with grade of zinc coating 275 complete all as specified and directed.
Material & labour for preparing new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Material & labour for lagging to pipes used in internal water supply (internal dia of pipe 15mm) or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and directed.
Material & labour for lagging to pipes used in internal water supply (internal dia of pipe 20mm) or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and directed.
Supply and fixing in repair Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
Rotational moulded polythene water storage tank 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule & nipple suitable for water tank and dismantling old unserviceable water tank of capacity exceeding 500 liters but not excedding 1000 Ltrs complete all as specified and directed.
Supply and fixing in repair anodised aluminiun snap grid frame work for false ceiling of size 605mm x 605mm with and including 12mm thick gypsum board and G.I hanger 6 mm dia (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long, complete all as specified and directed.
Supply and fixing powder coated anodised aluminium frame for door, window, ventilators with one or more rebates including jointing cleat for fixing etc complete all as speicified and directed.
Supply and fixing powder coated anodised aluminium door shutter, aluminum section weighing 0.55 Kg/M including necessary jointing cleats, glazig clips, rubber packing, anodised aluminum snap beading, screws, aluminium anodised handle (02 Nos in each door) hinges 100mm long (02 Nos) etc complete all as specified and directed.
Supply and fixing powder coated three track sliding window with two shutters, one 4mm thick float glass ordinary quality and one shutter with SS wire mesh 0.36mm dia wire and 1.40mm aperture including handle, lock PVC rubber lining etc complete all as specified and directed. make - Jindal aluminium cat. no. three track bottom - 20957
Supply and fixing aluminium mortice lock, vertical type of size 100mm, 4 lever fixed in door complete all as specified and directed.
Supply and fixing floor door stopper 140mm long aluminium alloy body anodized with hard drawn steel spring complete all as specified and directed
Supply & fixing aluminium door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
4.8mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
Supply and fixing solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturer complete all as specified and directed.
Supply and fixing in repair solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed
Supply and fixing 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed
Material & labour for vitrified ceramic tiles 10mm thick, light shade as approved, polished area of each tiles n. exc. 0.36 Sqm (square / rectangular) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed 15mm thick in cement mortar (1:6) finished rough to fix tiles including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises, complete all as specified or directed
Supply and fix in repair 25mm dia stainless steel curtain rod with and including fixing brackets, finale cap etc complete all as specified or directed
Supply and fix in repair weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps wrought both sides and edges shot and chamfered (on exposed edges) complete all as specified or directed
M&L for cleaning of SGSW /RCC/PVC sewage line of 100mm dia by rodding/auger rods & drain pipe machine as required for one manhole to another manhole including gully traps and getting out the sludge from any size of manholes and gully traps, before & after cleaning process of SGSW /RCC/PVC sewage line and well flushing using clean water through water bowser of pipe of any capacity (arranged by the contractor) and removing the sludge etc to a distance n.exc 250m and burying the same underground by digging pit of suitable size from habitant area and returning filling with excavated materials up to ground level including removal of surplus soil to a distance n.exc 250m with and including taking off manholes/gully trap covers and re-fixing the same after cleaning process complete all as specified and directed. Note:- T&P like rods, bamboos, rope etc shall deem to be include in this unit rate.
-ditto- as per item no 62 above but for 150 mm dia of pipe
-ditto- as per item no 62 above but for 200 mm dia of pipe
M&L for Cleaning of septic tank/soakage well of any capacity and depth incl inlet chamber, outlet chamber after mixing of contaminated waste effluent and sludge etc of septic tank by mixing machine to change the state of solid/semi solid sludge to liquid state by using extra water provided by the contractor if required and getting out through sewer jetting cum suction machine vehicle having tank of 10000 litre capacity from any location and disposal to suitable place outside MD land i.e. authorised civil location with and including taking off & re-fixing manholes covers etc. complete all as specified and directed.
M&L for cleaning and taking out sludge (solid/semi solid state) from septic tank of capacity 50 to 100 users and disposal to suitable place outside MD land i.e. authorised civil location complete all as specified and directed
M&L for cleaning and taking out sludge (solid/semi solid state) from septic tank of capacity 100 to 250 users and disposal to suitable place outside MD land i.e. authorised civil location complete all as specified and directed
M&L for cleaning and taking out sludge (solid/semi solid state) from septic tank of capacity 250 to 500 users and disposal to suitable place outside MD land i.e. authorised civil location complete all as specified and directed
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning filling in layers including leveling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Removing surplus spoil to a distance exc. 250m but not exc. 500m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Material & labour for salt glazed stoneware drain pipe Grade-A 100mm bore laid in trenches, jointed on and including concrete bed in cement concrete 1:3:6 type C-2 and packing under and haunching against the sides of pipes after they are laid and tested including demolition and breaking up drain pipes, 100 mm dia drain pipe of any type set in cement mortar complete all as specified and directed.
Material & labour for salt glazed stoneware drain pipe Grade-A 150mm bore laid in trenches, jointed on and including concrete bed in cement concrete 1:3:6 type C-2 and packing under and haunching against the sides of pipes after they are laid and tested including demolition and breaking up drain pipes, 150 mm dia drain pipe of any type set in cement mortar complete all as specified and directed.
Material & labour for salt glazed stoneware drain pipe Grade-A 200mm bore laid in trenches, jointed on and including concrete bed in cement concrete 1:3:6 type C-2 and packing under and haunching against the sides of pipes after they are laid and tested including demolition and breaking up drain pipes, 200 mm dia drain pipe of any type set in cement mortar complete all as specified and directed.
Cutting into existing manhole removing existing drain making good to wall and rendering cutting out branch channel and making good benching for 100mm dia pipe in cement concrete 1:2:4 complete all as specified and directed.
-ditto- as per item no 75 above but for 150 mm dia of pipe
-ditto- as per item no 75 above but for 200 mm dia of pipe
M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed. Note:- WPC will be measured and paid separately.
M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete with and including taking down cement or lime plaster or racking of pointing and scrubbing out existing finishes on wall of any for three storey bldg incl all necessary arrangement like scaffolding and masonry complete all as specified and directed. Note:- WPC will be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
Demolition of reinforced cement concrete of any descritption and in any position not otherwise speccificallt provided for as directed.
M&L for RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole cover slab and similar article with plain faces, set in cement mortar 1:4 complete all as specified and directed.
M&L for RCC M-30 design mix (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
S&F TMT Steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided complete all as specified and directed.
Material & labour for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete etc complete all as specified and directed.
Material & labour for cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping including necessary form work complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes complete all as specified and directed.
S&F in repair 110 mm PVC (SWR) access door bends any radius including taking down old complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) access door bends any radius including taking down old complete all as specified and directed.
S&F in repair 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed.
S&F in repair 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed.
S&F in repair 110mm PVC (SWR) vent cowl complete all as specified and directed.
Only fixed in repair any type of pipe 75mm bore fixed with walls complete all as specified and directed.
Only fixed in repair any type of pipe 100mm bore fixed with walls complete all as specified and directed.
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed.
Point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLS-H) drawn through and including PVC casing and caping (ISI marked) and accessories (fixed on wall/ceiling surfaces), terminated in and including pressed steel terminal boxes with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable (FRLS-H), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed.
All as per description of srl item No 99 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch.
All as per description of srl item No 99 here-in-before but socket out let 3 pin, 5 Amp on same board
All as per description of srl item No 99 here in before but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 2.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin switch socket combination, 15 Amps on independent board.
Switch piano flush button single pole one way 5 A, 240 V complete all as specified and directed.
Switch socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and directed.
Switch socket combination 5/15A, 5 in 1, 3 pin, 240 volts complete all as specified and directed.
Ceiling rose, surface bakelite, 65 x 50 mm, three terminals, 240 volts complete all specified and as directed.
Fan regulator, electronic type, five steps socket type single phase, including connection complete all as specified and directed.
Taking down unserviceable any type of main switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
MCB DB SPN 8 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
MCB DB TPN 4 way, 415 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
MCB SPN 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
LED lamp 1 x 9 watts suitable for pin type batten/pandent holder complete all as specified and directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fixing energy efficient surface Mounted LED Luminire 18/20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed. Make : - Bajaj Cat No BCLSB 18 WH /NW or equivalent in Philips/CG) complete all as specified and directed.
Supply and fixing in repair 1 x 45 watts LED street light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified. (Make : Bajaj Cat No BRTFG 45W LED I or equivalent in Philips/CG) complete all as specified and directed.
Supply and fixing in repair exhaust fan, steel body, AC, single phase. 230V of size 300m sweep with, blades, and frame and louvers etc complete all as specified and directed.
Supply and fixing in repair ceiling fan with blades and down rods and accessories, 230V, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct currrent motor etc complete all as specified and directed.
Material & labour in repairs for Earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia medium grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and directed.
LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 16 Sq mm, 2 core, with aluminium conductor, ISI marked for house service connections connecting from pole/panel to DB's etc complete including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 35 Sq mm, 3.5 core, aluminium conductor along with suitable size aluminium cable lugsand cable glands including taking down old unserviceable complete all as specified and directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
Supply and laying dry river sand locally available for as cable cushioning and covering complete all as specified and directed. Note :For Payment purpose punned thickness shall be measured and paid.
M/S GHULAM HASSAN KUCHAY
M/S B S CONSTRUCTIONS
M/S Thakur & Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .