Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.4 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹14.2 L+₹418 (0.03%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹14.5 L+₹29,492 (2.08%)Rejected-Finance OLD AIRPORT ROAD W ANBAL SRINAGAR J K 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹14.9 L+₹65,188 (4.59%)Rejected-Finance | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹15.6 L+₹1.4 L (9.75%)Rejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹36.3 L
EMD Value
₹72,700
Closing Date
23 Sept 2024, 6:00 pmClosed
Capt Manikanda Pandian N AGE EM, Offg GE
GE 970 EWS C/o 56 APO PIN-913970
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION WORKS IN OTM and MD ACCN AT OLD AIR FIELD UNDER GE 970 EWS
2024_MES_669673_1
GE 970 EWS-47/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OLD AIR FIELD SRINAGAR
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹72,700
Yes
5 Nov 2024
2 Sept 2024
30 Sept 2024
2 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) ISI marked medium grade white colour requirement with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switches, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed (1.5 Sqmm for phase and neutral and 1.5 Sqmm earthing) Note :-( Wiring shall be done by using colour coding (b) Earth wire shall be of green colour.
Description all as per item No. 4 here in before, but for one bell/buzzer point controlled by one bell push 5 Amp all as specified and as directed.
Description all as per item No. 4 here in before, but for one light point controlled by two 2-way switches all as specified and as directed.
Description all as per item No. 4 Above but for one ceiling fan point
Description all as per item No. 4 Above but for one exhaust fan point
Description all as per item No. 4 but for one 3/5 Pin, 5 Amp switch socket out let on the independent but below the switch board of light points in the same vertical plane ,with cables of 2.5 Sqmm size (2.5 Sqmm for phase and neutral and 2.5 Sqmm for earthing), complete all as specified and as directed
Description all as per item No 4 here in before, but for one 3/5 Pin, 5 Amp switch socket out let on the same board complete all as specified and as directed
M & L for one point wiring with PVC insulated sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including , ISI marked medium grade Non metallic rigid PVC concealed Conduit not less than 20 mm dia as per ground requirement with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switches, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed Note :- (a)cutting of wall and making good to the surface are also included in the unit rate quoted.(b) Wiring shall be done by using colour coding (c) Earth wire shall be of green colour.
Description all as per item No. 11 here in before, but for one bell/buzzer point controlled by one bell push 5 Amp all as specified and as directed.
Description all as per item No. 11 Above but for one ceiling fan point
Description all as per item No. 11 Above but for one exhaust fan point
Description all as per item No. 11 but for one 3/5 Pin, 5 Amp switch socket out let on the independent but below the switch board of light points in the same vertical plane ,with cables, ,2.5 Sqmm size (2.5 Sqmm for phase and neutral and 2.5 Sqmm for earthing)complete all as specified and as directed
Description all as per item No 11 here in before, but for one 3/5 Pin, 5 Amp switch socket out let on the same board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping (double interlock type) of as required width (not less than 20 mm in width) ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC Box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed. Note :- (a)cutting of wall and making good to the surface are also included in the unit rate quoted. (b) Wiring shall be done by using colour coding (c) Earth wire shall be of green colour.
Description all as per item No 17 here in before, but one switch socket combination 2 in 1, 3 pin, 5 / 15 Amp drawn through and inculding Non metallic rigid PVC Conduit not less than 20 mm dia fixed on surface of walls / ceilings etc complete all as specified and as directed.
Description all as per item No 17 One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size (main & earth wire)
M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC concealed Conduit not less than 20 mm dia as per ground requirement with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of 2.5 Sqmm wire and one run of 2.5 Sqmm earth continuity and one run of PVC conduit shall be measred as one unit)
Description all as per item No 20 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed. (Note :- Two runs of 4 Sqmm wire and one run of 4 Sqmm earth continuity and one run of PVC conduit shall be measred as one unit)
Description all as per item No 20 here in before, but two run of single core 6 sqmm and one run of 6 sqmm cables as earth continuity conductor all as directed. (Note :- Two runs of 6 Sqmm wire and one run of 6 Sqmm earth continuity and one run of PVC conduit shall be measred as one unit)
S&F Switch Piano flush button single pole one way 5 A , 240 V complete all as specified and as directed
S&F Switch Piano flush button single pole two way 5 A , 240 V complete all as specified and as directed
S&F Bell push flush button, single pole, one way, 240 V, 5 A complete all as specified and as directed
M&L Call bell ding dong AC, 230 volts, single pole all as directed
S&F Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
S&F Stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
S&F Switch Socket Combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed
S&F Switch Socket Combination 5A, 2 in 1, 5 pin, 240 volts complete all as specified and as directed
S&F Socket outlet, 5A, 3 pin, 240 volts complete all as specified and as directed
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
S & F in repairs MCB DB SPN 8 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
Description all as per item No 33 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
Description all as per item No 33 here in before but MCB DB SPN 4 way DB 415 V with 200 A rated busbar.
S & F MCCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCCB TPN 100 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SPN 40 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SPN 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs LED lamp 1 x 9/11 watts suitable for pin type batten/pandent holder complete all as directed.
S & F in repairs Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking down Old UNSV tube light fitting /reccess mounting /bulk head post /post top gate light /any light fitting/capacity complete alll as specified and directed.
Supply and fix in replacement 1×18/22 watts 4' long,LED Battern housing with white diffuser and inbuilt electronic driver system lumen output should be at least 1800/ 2200 lumen with a CCT of 6000k,power factor should be greater than 0.95 with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed. NOTE (i) contractor shall provide 2 year writern manufacture's warranty for the LED fixture complete including driver from the certified date of completion.
Supply anfd fixing in replacement square LED panel light fitting ceilling/recess mounting type with slim ,compact ,aluminium die cast edge lift panel completer with opal diffuser and electronic driver inbuilt of capacity 36 watt complete all as specified and directed . NOTE (i) contractor shall provide 2 year writern manufacture's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fix in replacement energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.
Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for :- (a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) CI cover with suitable handle (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified. (e) 15mm nominal bore light grade GI protection pipe up to 7.50 meter long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
M/s Jaipal Associates (BID ID -3108541)
M/s Bashir Enterprises (BID ID -3108355)
M/S MIR SAJAD ENTERPRISES (BID ID -3105930)
M/s GHULAM NABI HAJAM (BID ID -3106216)
M/S LATIF AHMAD BABA CONSTRUCTION (BID ID -3108697)
M/S M.Y Enterprises (BID ID -3100171)
M/s Nasir Rasool Dar (BID ID -3104520)
FIRDOUS AHMAD BABA (BID ID -3109124)
M/S B A Traders (BID ID -3108976)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .