| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.0 LAccepted-AOC HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹95.4 L+₹4.9 L (5.44%)Rejected-Finance SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹1.2 Cr+₹24.7 L (27.3%)Rejected-Finance WZ 484 M S BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹1.2 Cr+₹27.4 L (30.3%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹1.2 Cr+₹32.2 L (35.6%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
2 Dec 2021, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
ADDN ALTN AND SPECIAL REPAIRS TO ROOF OF TRAINEES LIVING ACCNS AND AMENITY ROOMS AT MIL STN GAYA
2021_MES_483626_1
80599/1382/E8
Open Tender
Civil Works - Others
Item Rate
180 days
Gaya
Class B category a(i)
6 documents required · 6 mandatory
₹1,000
Yes
GE Gaya
₹2.1 L
Yes
20 Dec 2021
27 Oct 2021
4 Dec 2021
27 Oct 2021
2 Dec 2021
18 Nov 2021
Amount
Taking down cement plaster including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) mixed with liquid water proofing compound @ 0.200 ML per bag of cement or as per manufacturere's instructions, on wall, finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately)
M&L one coat of exterior emulsion paint ( Apex or weather coat) , white or tinted on old surfaces of walls or facia of roof or chajjas including prepration of old surfaces and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L two coats of exterior emulsion paint ( Apex) , white or tinted over a coat of exterior primer on new surfaces of walls or facia of roof or chajjas including necessary preparation and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
S&F PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp complete all as specified and directed.
M&L PVC (SWR) bend of any radius 110mm dia complete all as specified and directed.
Demolition of brick works masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M & L for brick work with subclass “B” Old size bricks, straight or curved on plan exceeding 6 m mean radius built in CM (1:6) complete all as specified and directed.
S&F in repair Rotational moulded poly-ethylene multilayer water storage tanks ( cylinderical vertical with closed top ) 1000 litres capacity ,hoisted and fixed in position including 25mm dia PTMT float valve & ball complete all as specified and as directed.
S&F in repair Chromium plated fancy type Stop valves / angle valves, cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for iron pipes or for unions etc. and fixed complete all as specified
S&F Gunmetal , globe or gate valves, with iron wheel head, screwed both ends for 25 mm bore dia. iron pipe and fixed complete all as specified.
M&L machine cut Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10mm thickcement screed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to give granite finish complete all as specified.( Screed bed shall not be measured and paid separately).
M & L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3 complete all as specified and directed.
M&L for rubber moulded red coloured pre- polished machine pressed cement concrete tiles with grey cement and pigment of size (30cm x 30 cm) x 30mm thick with and including over 15mm thick screed bed in CM (1:6), set jointed and pointed in neat cement slurry in floors complete all as specified and as directed.
Supplying and laying of 32mm bore CPVC pipes SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified
Supplying and laying of 25mm bore CPVC pipes SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified
S&F Female Brass threaded adaptor FTA/FBTA, suitable for 25mm bore CPVC pipe outer dia complete all as specified and directed.
M&L 20 mm thick granite stone slab ( of any type) work , bedded over screed bed and jointed in cement mortar to match the colour of slab as in flooring , polishing and grinding , laid over 15mm thick screeding in CM 1:4 complete all as specified.( Note Screed bed shall not be measured and paid separately).
M&L 20 mm thick Granite ( of any type) work ( table rubbed and polished) in skirting / dado , jambs, pillars,etc and like including polishing and grinding complete, set in cement mortar ( 1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 10mm thick rendering in CM 1:4 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premices complete all as specified and as directed.
M&L for coloured glazed ceramic tiles as in vertical surfaces of size (350x250)mm x7mm /(450x350) x7mm thick with and including over10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but n.exc 0.11 sqm as in floor etc, with and including over 15 mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified.
M&L Reinforced Cement concrete in cement concrete mix 1:2:4, type B1 (using 20mm graded stone aggregates) as in slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Use and waste of Form work to flat soffits of suspended slabs, floor slabs, landings and similar work; not exceeding 200 mm thick ( Horizontal or sloping) surfaces finished fair in forms complete all as specified.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs excd 10 cm and n exc 20 cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work complete all as specified surfaces finished fair in forms complete all as specified.
M&L Mild steel deformed or twisted bars ( TMT) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or higher complete all as specified.
M&L for providing water proofing treatment over cleaned roof surface with super thermo APP modified polymeric membrane comprising of followings :- (i). Complete removal of existing roof treatment by picking, sweeping clean and washing down with water to remove dust etc from plastered / roof surface / walls and filling the crackes with sealing compound grade 'A' . (ii) Rendering / screed bed 15 mm thick in cement mortor (1:4) mixed with liquid water proofing compound as per manufacturer's instructions and finished the surface fair and even. (iii) Applying evenly a coat of bitumen based primer conforming to IS-3384-1965 @ 0.30 Kg/Sqm. (iv) Applying 3 mm thick APP modified polymeric membrane with non polyster reinforcement of approved make, weight not less than 3.50 Kg/Sqm laid with gas torch and fastedon roof surface with roller. The over laps 100mm and shall be sealed by torch application as per manufacture instructions including vertical surfaces after cutting necessary grooving and making good with PCC 1:2:4 type B-O with sika latex power as per manufacture instructions. (v) Applying two coats of bituminous anticorrosive multi purpose aluminium coating (super silver shield) @ 150 gm/sqm per coat over polymeric membrene. Note :- WPC shall be measured and paid separately.
S&F in repair Vitreous China white wash down water closet ( padestal pattern) , plastic water closet seat, black, closed pattern with recessed bottom and cover and mild steel CP hinging device, including fixing bolts but excluding flushing cistern and flush pipe complete all as specified and directed.
Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing ( Except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
M&L for point wiring complete with PVC insulated and unsheathed cable FRLS 1.5 Sqmm multi stranded copper conductor cable conforming to IS:694, two single core drawn thorugh and including 20mm dia PVC conduit medium grade ISI marked in concealed in wall 1.60 mm thick pressed steel concealed terminal boxes and with top cover 3 mm thick ISI marked plastic laminated hylum sheet fixed with brass screws and cup washers painting terminal boxes inside and out side with one coat red oxide primer compete with all accessories and all as specified including one run FRLS1.5 Sqmm PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth dolly including colour coding of cable as specified in SSR Part-I (2009) & making good disturbed area of wall with cement work & white wash etc to match with the existing surfaces, complete all as specified and as directed for the following:-
One light point/fan point / bell point controlled by one switch
One socket out let point 5 Amps on independent board
One 3 Pin socket out let point 5 Amps on same board with other switch
M&L for point wiring for one socket out let point complete with PVC insulated and unsheathed cable FRLS 2.5 Sqmm multi stranded copper conductor cable conforming to IS:694, two single core drawn thorugh and including 20mm dia PVC conduit medium grade ISI marked in concealed in wall 1.60 mm thick pressed steel concealed terminal boxes and with top cover 3 mm thick ISI marked plastic laminated hylum sheet fixed with brass screws and cup washers painting terminal boxes inside and out side with one coat red oxide primer compete with all accessories and all as specified including one run FRLS 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth dolly including colour coding of cable as specified in SSR Part-I (2009) & making good disturbed area of wall with cement work & white wash etc to match with the existing surfaces, complete all as specified and as directed .
S&F switch piano flush button type single pole , one way 5 Amp complete all as specified and as directed.
S&F ceiling rose surface bakelite 65x50mm, 2 to 3 terminals complete all as specified and as directed.
S&F socket out let , 2 in 1, 5 Pin, 6 Amps flush type complete all as specified and as directed
S&F switch socket combination 6 Amp, 5 Pin, flush type complete all as specified and as directed
S&F switch socket combination 5 & 15 Amp 5 Pin, flush type complete all as specified and as directed
S&F socket out let , 2 in 1, 6 and 16 Amps flush type complete all as specified and as directed
S&F MCB Distribution Board double door , made out of CRCA steel sheet with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface / concealed mounting, TPN 4 way, 440 volts with bus bar rating 200 Amps ( vertical operation) and suitable size of cable gland - 02 Nos, dust and vermin proof suiatble for provision of MCCB 16 kA, 125 Amps , FP and SP/TPN MCBs with metal door complete all as specified and directed. ( Note :- FP MCCB 16 kA, 125 Amps, MCBs and Blanking plate shall be measured and paid separately)
S & F in replacement sheet metal enclosure distribution board, SPN, 8 way, 240 volts, with 200 Amps raed bus bar , double door for MCB , grouted flush to walls complete with IP 43 protection and metal door complete all as specified and directed.
S&F DPX MCCB , 125 Amps, 4 pole, 16 KA, 415 volts complete all as specified and directed.
S & F MCB of the following rating and to be housed in DBs catered here in after complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating):-
MCB SP, 'C' curve, 6 to 32 Amps
MCB SPN, 'C' curve, 40 to 63 Amps
S&F LED security light / street light fitting 35 / 36 Watt 230 V AC , new generation energy saving & enviromental friendly long life, made up of pressure die cast aluminium housing and heat resistant with mid power LED as lighting source and PC cover having top opening including complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection and impact resistance of IK07 with and including GI bracket made of 32mm dia GI pipe medium grade, not exc 1.5 M long, made to shape and size of MS clmaps, (2 Nos) made out of 50x6mm flat iron, 12mm dia nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of primer including necessary connection from LT OH line / building complete all as specified and directed.
S&F wall mounted LED tube light fitting 20 Watts batten for surface mounted, anodised extruded alluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 V and integrated electronic driver connector block etc with installation complete with all accessories, internally pre-wired and necessary mounting arrangements, provision of new 3 core multi stranded copper conductor cable of size 23/0.193 from ceiling rose to fittings complete all as specified and directed. Make :- Crompton Greaves Cat Ref No CCS-100-20-65-HL2-DP-NWH 20W or other equilant in Philips / Bajaj / Havells as approved by the GE
Disconnecting and Taking down carefully tube light fittings from existing position and cleaning the same properly and reaasembling and refixing the same after completion of repair work / painting work complete all as specified and directed.
Supply and laying in replacement or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 35 sq. mm 3 ½ core nominal cross section including testing complete all as specified.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.50m in depth for foundation, pier holes, laying of cable etc n exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed .
Removing excavated material to a distance not exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.complete all as specified and directed .
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion including taking out exisitng earthing system complete all as specified and directed.
M&L for 40 mm bore steel tubing light grade ISI marked laid in trenches / road / along pole for protection of cable including necessary joints complete all as specified and as directed.
M&L for Sub main wiring two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor,drawn in and including non metallic rigid PVC conduit medium grade, inclusive of all fitting such as tees, bends. Junction boxes, elbows saddles etc of size 25 mm dia in concealed in walls / roof / floor etc by cutting of wall and making good disturbed surface of wall as per existing and including PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green colour PVC insulated as contineous earth conductor cable including dismentling of unserviceable sub main wiring and accessories complete all as specified and as directed.
M&L for laying of HDPE double wall corrugated pipes in trenches for UG cable protection , conforming to IS:14930 Part-II with IP-67 having outer dia 50mm and inner dia of 38 mm including necessary fittings such as couplers, bend etc complete all as specified and as directed.
S&F switch piano flush type single pole , one way 16 Amp complete all as specified and as directed.
M/S ABHAY KUMAR AND BROTHERS
MS HARI MOHAN GUPTA
m/s meetu enterprises
venkateshwara infra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .