| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹17.3 L+₹30,107 (1.78%)Rejected-Finance COLABA MUMBAI | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹18.6 L+₹1.6 L (9.67%)Rejected-Finance | L3 | Rejected-Finance Not the lowest e-tenderer | |
| 4 | L4₹19.6 L+₹2.6 L (15.5%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Not the lowest e-tenderer | |
| 5 | L5₹20.3 L+₹3.3 L (19.6%)Rejected-Finance | L5 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
Refer Docs
EMD Value
₹41,000
Closing Date
29 Apr 2021, 6:00 pmClosed
COL SANTOSH PANDEY CWE (ARMY) MUMBAI
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPLACEMENT OF 11KV UNDERGROUND XLPE CABLE AND CONNECTED ITEMS OF COLABA MIL STATION UNDER GE (WEST) COLABA MUMBAI
2021_MES_433952_1
84019/W/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST COLABA MUMBAI
refer the tender documents
7 documents required · 7 mandatory
₹500
GE WEST COLABA MUMBAI
₹41,000
21 Jun 2021
1 Apr 2021
30 Apr 2021
1 Apr 2021
29 Apr 2021
15 Apr 2021
1 Apr 2021 - 22 Apr 2021
Amount
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out complete in soft/loose soil all as specified.
All as per sl. item No.01 above but in hard/dense soil.
All as per sl. item No.01 above but in hard/dense soil and depth beyond 1.5m depth.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft/ disintegrated rock/road cutting/RCC/PCC complete all as specified and directed.
Supply and providing sand for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thickness will be measured.
Returning,filling in any type soil/rock including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified.
Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil
Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed.
Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of Class HV type I with peak, flat size 300x180x40 mm putting adjecent to each other as specified. Make:- (i) Topaz (ii) Mehtab (iii) Jhonson
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. Make:- (i) Raychems (ii) Densens (iii) Birla-3M (iv) M-Seal.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. Make:- (i) Raychems, (ii) Densens, (iii) Birla-3M, (iv) M-Seal.
Supply and laying GI tubes of light grade, 150 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed. Make:- (i) Jindal, (ii) Tata, (iii) Zenith, (iv) Swasthik, (v) Surya.
Taking down Old HT cable and Supply,laying in trench, for boring for holes under road, pavement or hard standing ,and testing in replacement for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed. Make:- (i)Havells (ii)Universal (iii)Gloster (iv)Polycab (v)Asian. Notes:- (i) XLPE cable will be laid on main road substn No 01 to 02, and substn 06 to BI Line. (ii) Earth work, Road cutting/Hard standing will measured separately on relevent items. (iii)All site should be cleared immidiately after cable laying.
M&L cement concrete 1:2:4 type B1 using 20mm graded aggregate in width for foundatuion/road filling including including rafts, footings, foundation beams plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified and directed.
M&L for granite (black colour) tiles 20mm thick machine cut, bedded and jointed as in floor and gate/wall with neat cement slurry and pointed with cement with admixture or pigmen to match the shade of tiles incl bed 15 mm thick CM 1:6 including grinding and polishing complete all as specified and directed.
Taking down interlock tiles for excavation for HT cable laying and Refixing of interlocking tiles after cable laying complete all as specified and directed.
Veer High Tech Solution
Pan Electricals
AGRAWAL ASSOCIATES
ELECTRO ASSOCIATES
NATIONAL ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .