Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | ₹17.7 L Quoted ₹18.3 L | L1 | Accepted-AOC Being the lowest |
| 2 | L2₹18.8 L+₹43,819 (2.39%)Rejected-Finance | ₹18.8 L+₹43,819 (2.39%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹18.8 L+₹48,934 (2.67%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | ₹18.8 L+₹48,934 (2.67%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹18.9 L+₹63,296 (3.46%)Rejected-Finance NO 32 KR RAMASAMY STREET MGR NAGAR CHENNAI 600 078 | CHENNAI | TAMIL NADU | 600078 | ₹18.9 L+₹63,296 (3.46%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹20.2 L+₹1.9 L (10.3%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹20.2 L+₹1.9 L (10.3%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
11 Sept 2021, 6:00 pmClosed
GARRISON ENGINEER
Garrison Engineer (AF) Air Force Station Tambaram, Chennai - 600 046
REPAIRS / REPLACEMENT OF CEILING FAN / EXHAUST FAN / WALL FAN / PEDESTAL FAN / AIR CIRCULATOR FAN, GEYSER ,SOLAR WATER HEATER AT MAIN CAMP AT AF STATION TAMBARAM
2021_MES_468063_1
GE(AF)/TAM/8490/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF TAMBARAM
₹52,000
Yes
29 Sept 2021
14 Aug 2021
13 Sept 2021
14 Aug 2021
11 Sept 2021
28 Aug 2021
14 Aug 2021 - 21 Aug 2021
Amount
Taking down carefully existing ceiling fans of any size from its position, removing the blades from fan, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bushes , burnt winding, shaft, split pin, condenser etc reassembling after winding and replacing defective parts with new parts including provision of 3 core 1.50 Sqmm) flexible copper cable from ceiling rose to connector , refixing of removed blades and hanging in its original position properly including necessary testing after hanging complete all as specified and directed. Note :- (a) Quoted rate shall be inclusive for grease,bushes,shaft,split pin etc (b)Winding of ceiling fan and spare parts such as ball bearing,capacitor etc required to making the ceiling fan serviceable shall be measured and paid separately under relevant items here in after.
Taking down carefully existing exhaust fan/wall mounted/pedestal fan /Air circulator of any size from its position removing the louvers and blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing defective parts such as ball bearing, bush , burnt winding, shaft, split pin, condenser etc and reassembling after winding and replacing defective parts with new parts including provision of 3 core 1.50 Sqmm flexible copper cable from ceiling rose to connector , refixing of removed blades ,louvers etc and fixing in its original position properly including necessary fixing bolts,nuts etc as required and testing after fixing complete all as specified and directed. Note :- (a) Quoted rate shall be inclusive for gease,bushes,shaft,split pin etc (b)Winding of exhaust/wall mounted/pedestal fan/Air circulator and spare parts such as ball bearing,capacitor etc required to making the exhaust /wall mounted/pedestal fan serviceable shall be measured and paid separatly under relevant items here in after.
Material and labour for rewinding of following fan motor with super enamelled copper winding wire of same gauge and weight as per existing and weight including cleaning of rotor, stator , varnishing, heating and provision of fresh insulating materials for the following size of ceiling / exhaust /pedestal /wall mounted fan all as specified and directed.
Exhaust fan 225mm to 300mm sweep
Pedestal fan 400mm to 600mm sweep
Wallmounted fan 400mm sweep
Ceiling fan of 1200/1400 mm sweep
Air circulator fan of 1600 mm sweep
Material and labour for cleaning and preparing the surfaces of ceiling fan of any sweep , removing the grease, carbon dust over the fans ,filling cavities with filler and applying one coat of synthetic enamel paint of approved colour by spraying including writing MES number on the fan complete as in situ all as specified and directed.
Material and labour for cleaning and preparing the surfaces of exhaust fan/wall mounted fan/pedestal fan/Air circulator of any sweep and type , removing the grease, carbon dust over the fans ,filling cavities with filler and applying one coat of synthetic enamel paint of approved colour by sprying including writing MES number on the fan complete as in situ all as specified and directed.
Supply only ball bearing suitable for ceiling fan of size 1200/1400mm sweep
Supply only ball bearing suitable for exhaust fan/wall mounted fan/pedestal fan of any size and make
Supply only condenser of 2.5 MFD capacity
Supply only condenser of 4 MFD capacity
Supply only GM bush suitable for ceiling fan of size 1200/1400mm sweep
Supply only bush suitable for exhaust fan of any size and make
Supply and fixing fan regulator electronic type with 5 step control suitable 1200/1400mm ceiling fan
M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed
Taking down defective storage water heater (Geyser) of any type and make upto 50 litres capacity from buildings by disconnecting carefully water and electric connection, opening the bottom cover descaling the inner container , heating element,base assembly using diluted hydrochloric acid cleaning thoroughly, filling the inner container with water for leakages testing if any leakage found, arrest the leakage by proper bracing and replacing the defective parts, fixing the bottom cover and refixing in its original position, reconnecting both water and electric connection and testing complete all as specified and directed Notes :- Spares required for replacement shall be measured and paid for separatley under relevant items.
Supply only new heating element of capactity 2.0KW with rubber gasket thread/push type 230v complete all as specified and directed.Make:Bajaj/Usha/Racold
Supply only thermostat suitable for geysers of 25 to 50 litres storage capacity water heater and range 30 to 80 degree centigrade and cut off at 70 degree centigrade complete all as specified and directed.
Supply only PVC connection pipe 15mm dia 450mm long heavy duty suitable for hot / cold water with two brass union and washer complete all as specified.
Material and labour for servicing the solar water heater of any make/ type/ capacity and cleaning/ descaling of solar collecting panel of copper pins/ tubes including replacing the sacrificial anode rod and panel tuffen glass 4mm thick of size 2m x 1m all as specified and directed
Matrerial and labour for GI tubes 40mm bore medium grade with all fittings and fixed on wall/ceiling for hanging of ceiling fans including taking down the existing pipe complete all as specified and directed
Supply and fix ceiling fan down rod fabricated out of 15 mm dia GI pipe medium grade including cutting/ threading/ drilling etc. and provision of check nut ,split pin , 'U' clamp bolts, nuts, washers, rubber split pin etc as required for ceiling fan of 1200/1400 mm sweep including taking down existing downrod with acessories complete all as specified.
Supply and fix ceiling fan hook made out of mild steel flat iron of size 40mm x6 mm thick bend to shape as required for hanging ceiling fans including taking down existing fan hook complete all as specified.
Material and labour for submain wiring with two runs of 4.0Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor and one run of 4.0 Sqmm of PVC FRLS copper cable as earth continuity conductor drawn through in existing surface/recessed steel/pvc conduit with accessories on surface of wall/ceilings all as specified including taking out the existing submain wiring and making good the disturbed portion to match with existing surface complete all as specified and as directed by Engineer- in- charge.
All as per Item No 22 here-in-before but with two runs of 6.0 Sqmm submain wire and 1x 6.0 sqmm as earth continuity conductor.
All as per Item No 22 here-in-before but with two runs of 10.0 Sqmm submain wire and 1x 10.0 sqmm as earth continuity conductor.Note for Sl item No 22 to 24 :- Two runs of 10/6/4 sqmm single core multistranded copper conductor and one run of earth continuity conductor shall be measured as one unit length
Supply and fix in repair MCB SP 6 to 32 Amps ‘B’ Series MCB, 10 KA , 240V
Material and labour for earthing complete with GI plate electrode 600mmx600mmx6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4mm dia GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work , PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick with 8mm TMT bar 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal ,salt connected to earthing test point including necessary testing and commissioning on completion complete all as specified and directed and taking out existing unserviceable earthing.
SJM CONSTRUCTIONS
Banyan Engineers and Contractors
M/S CLIMATE CONTROLS
EVEREST ENGINEERING WORKS
Global Safety Engineering and Management Solutions
RADHIKAGANESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .