Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.5 LAccepted-AOC B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L-1 | Accepted-AOC Lowest bidder for the subject work. | |
| 2 | L-2₹12.8 L+₹4.2 L (49.7%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | Rejected-Technical FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | - | Rejected-Technical CONDITIONS NOT COMPILED WITH |
| Sl No | Description | Qty | Unit | SAMEER ELECTRICAL SUPPLIER L1 | MONA GENERATOR SEVICES PVT. LTD. L2 |
|---|---|---|---|---|---|
| 1.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 5.2 of capacity 1.5 Ton complete all as specified and directed. | 2 | Each | 45,000 ₹90,000 Lowest | 55,915.27 ₹1,11,830.54 |
| 2.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 5.2 of capacity 2 Ton as complete all as specified and directed. | 6 | Each | 60,000 ₹3,60,000 Lowest | 61,911.91 ₹3,71,471.46 |
| 3.00 | S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed. | 8 | Each | 800 ₹6,400 Lowest | 1,366.57 ₹10,932.56 |
| 4.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 03 KVA complete all as specified and directed. | 2 | Each | 2,000 ₹4,000 Lowest | 4,068 ₹8,136 |
| 5.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 04 KVA complete all as specified and directed. | 6 | Each | 2,500 ₹15,000 Lowest | 4,633.87 ₹27,803.22 |
| 6.00 | Supply, installation, commissioning and testing of Diesel Engine driven generating set 25 KVA, 415 Volts, 3 phase 4 wire, engine complete with integral acoustic enclosures as per latest Indian Standards of central pollution control board and as alternator with relay, Control panel, sound proof canopy and PCC foundation of required size for DG set as per manufacturer's instructions complete including the following: -
(A) ENGINE: -
(i) 3 Cylinder, In-line 4 stroke.
(ii) Turbocharged and intercooled cooling system
(iii) Stainless steel exhaust flexible coupling and exhaust pipe
(iv) Radiator water cooled
(v) Coolant inhabitor
(vi) Plate type lubricant oil cooler
(vii) Spin-on filters coolant, fuel & lubricant oil.
(viii) Dry type heavy duty replaceable paper element air cleaner with restriction indicator.
(ix) Electronic governor
(x) Electric starting system
(xi) Battery charging alternator.
(xii) 12 volts 88 AH/suitable as company design maintenance free battery with multi stranded copper cable for connecting wire and terminal complete
(xiii) First fill lub oil.
(B) ALTERNATOR: -
(i) 4 P rotating field, 415V, 50 HZ, Brushless type
(ii) Voltage regulation plus/minus/+1 percent.
(iii) IP- 23 protection with Class 'H' insulation
(iv) Flex disc type coupling
(v) Automatic voltage regulator.
(vi) Noise level 75 dBA @ /meter
(vii) Telephone interference factor .50
(viii) Total harmonic factor better than 2%
(ix) Supplying power to variable electrical load for unlimited hours. Prime power (PRP) is in accordance with ISO 8523. 10% overload capacity for 1 hours every 12 hours of operation and will be suitable tropical conditions. | 1 | Each | 3,60,000 ₹3,60,000 Lowest | 7,18,377.38 ₹7,18,377.38 |
| 6.01Item 6.01 Contd/-……. (C) FUEL TANK: - (i) Fuel tank suitable capacity for 12 Hrs on full load with provision for supply and return lines, level indicator, drain valve, cleaning cover, vent pipe & locking devices shall be provided. (ii) Fuel pipe line from fuel tank to FIP of suitable size. (iii) The fuel tank has to be mounted / located inside the cubicle. (D) ACOUSTIC ENCLOSURE: - (i) Designed to meet stringent MOEF/CPCB-IV+ norms 75 dBA @ 1 meter. (ii) Air inlet louvers to be designed to operate at rated load even at 50-degree centigrade air inlet temp. Four points lifting for easy handling. (iii) Cubical to be powder coated for long lasting service life and super finish with UV resistant powder coating, it has to with stand extreme environment. Has to be use stain steel hardware. (iv) Insulation material conforming to IS 8183 specs for better sound. (v) Genset control unit with integrated E-governor helps in reading all genset inputs and controls the genset GCU help in monitoring of following parameters, Controls the engine speed,3 ph genset, low fuel level, support manual control (MCP) functions for 3 phase genset, Measres Genset, Measures Genset Voltages and currents, Measures electrical parameters like frequency, Power factor, Generator, KVA, KW, KVAr, Monitor critical engine safety parameters, Starts/Stops the genset, Have counters for genset start/stop, run hours, KWH, power factor (E) INBUILT AMF CONTROL PANEL FOR DG SET: - (I) MCCB 63 Amps, 4 pole, 415 volts, 10 KA, 50 Hz - 02 Nos (ii) Power contactors of suitable sizes, Air break type - 02 Nos (iii) Digital type multi-functional meter -01 Nos, Glass Relay (DVR), Glass Relay, , Relay base, start/stop, relay board, MCB SP, selector, integral LED pilot, toggle switch and other equipment as required for smooth functioning of genset (iv) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos (v) Microprocessor based relay of suitable size/ratings-01 Nos (vi) Battery charger auto/manual switch - 01 Nos (vii) Suitable communication with features of following protections: - Over current, overvoltage, under voltage, under frequency, Low pressure oil. (viii) Genset shall be fully automatic ie auto on when mains fail and auto off when mains on complete | |||||
| 6.02Item 6.01 Contd/-……. (F) MAINTENANCE AND OPERATIONAL MANUAL OF PLANTS - 01 SET SHALL BE SUBMITTED BY CONTRACTOR ALONGWITH THE FOLLOWING: - (I) Test certificate of Alternator. (ii) Test certificate of Diesel Engine. (iii) Test certificate of Gen Set (by OEM). (iv) Test certificate of Acoustic enclosure. (v) Rubber mat. Notes: (a) Provision of PCC platform as per manufacturer guidelines/specifications and shall be of required size. The cost of the same shall be deemed to be included in the unit quoted rates. Nothing shall be admissible on this account (b) Testing of the DG set shall be carried out by the IEM (c) The contractor shall submit specification and drawing for approval of the GE before procurement of the DG set (d) Resistive load whether water load or strip heaters of suitable capacity and POL/DHPP for testing of DG set to be made available during test by the contractor. The cost of the same shall be deemed to be included in the unit quoted rates. (e) The DG set shall be procured from authorized OEM and of same group. The acoustic panel shall also be manufactured by the same OEM (f) Any other details not mentioned above but is required for efficient functioning of DG set is deemed to be included in the unit quoted rate | |||||
| 7.00 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. | 4 | Each | 4,500 ₹18,000 Lowest | 7,187 ₹28,748 |
Tender Value
₹9.6 L
EMD Value
₹19,220
Closing Date
20 Oct 2025, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
PROVN OF INSTALLATION OF 08 X AIR CONDITIONERS AND 25 KVA GEN SET FOR POWER BACKUP AT BLDG NO P-773 FOR ONLINE EXAMINATION CENTER UNDER GE BHOPAL
2025_MES_728489_2
84072/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹19,220
Yes
14 Nov 2025
1 Oct 2025
22 Oct 2025
1 Oct 2025
20 Oct 2025
8 Oct 2025
1 Oct 2025 - 8 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
84072TenderDocuments.pdf
Tender Documents • 1.20 MB
BOQ_821296.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .