Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.3 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING L-1 | |
| 2 | 2₹4.5 L+₹13,432 (3.09%)Rejected-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | 2 | Rejected-AOC REJECTED NOT BEING L-1 | |
| 3 | 3₹4.7 L+₹35,242 (8.11%)Rejected-AOC | 3 | Rejected-AOC REJECTED NOT BEING L-1 | |
| 4 | 4₹5.0 L+₹60,922 (14.0%)Rejected-AOC | 4 | Rejected-AOC REJECTED NOT BEING L-1 | |
| 5 | 5₹5.0 L+₹63,852 (14.7%)Rejected-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | 5 | Rejected-AOC REJECTED NOT BEING L-1 |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
22 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE I CIF R PIN-934756 c/o 56 APO
PROVN OF 100 KVA STABILIZER
2020_MES_394702_1
AGE(I)/R-15/2020-21
Open Tender
Miscellaneous Works
Item Rate
120 days
SAROL
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
AGE (I) CIF (R)
₹9,400
Yes
29 Jan 2021
23 Nov 2020
25 Dec 2020
23 Nov 2020
22 Dec 2020
8 Dec 2020
60 days
Amount
Supply install, testing and commissioning of servo controlled voltage stabilser (Confirming to as per BIS 9815 : Part 1:1994 reffirmed 2009) three phase, 50 Hz, naturally oil cooled, indoor unbalanced type copper wound, digital display type relay free smooth and silent operation with and including 1st flling of transformer oil and having following specifications:- (a) Input voltage 250v-480v (b) Output voltage stabilised at 415V+1%. (c) Rated frequency 50 Hz. (d) No distoration in wave form. (e) Response time not to exeed 10 mille seconds. (f) Sensitively +1%. (g) Rate of correction 8 volt / second for single phase and 20 v/seconds for phase to phase. (h) Efficiency more than 95%. (j) Digital display voltmeter , Ammeter. (k) Capacity 100 KVA. (l) Protections:- (i) Over load/short cirecuit protection. (ii) High/low voltage cut off. (iii) Bypass arrangement in case of emergency. (iv) Single phase sequence change operation. Make: Powerware/Andrew Yule/M/s Vintek Electronics (Volina)/Sinetrac.ITE/Aplab.
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles along with cable glands and alumiium lugs at LT Panel and Transformer etc complete all as specified and directed. Make: Finolex/Havells/Polycab
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised iron strip 32x6mm as earth lead by means of bolts, check nuts and washers of GI and earth strip protected by provision of GI pipe light grade, 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM ( weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 40mm dia, medium grade, GI pipe as protection to earth lead and earth lead as 32x6mm dia GI strip (main earthing lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and as directed.
Removing excavated material (soils) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed.
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
M/S A K ENGINEERS & CO.
CHOPRA CONSTRUCTIONS
BINDRA ENGINEERS AND CO
NATIONAL TRADING COMPANY
M/S PARSHOTAM KUMAR GUPTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .