| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC Awarded as first lowest bidder (L1) | |
| 2 | L2₹33.7 L+₹18,351 (0.55%)Rejected-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L2 | Rejected-AOC Awarded as second lowest bidder (L2) | |
| 3 | L3₹34.2 L+₹72,808 (2.17%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L3 | Rejected-AOC Awarded as third lowest bidder (L3) | |
| 4 | L4₹34.9 L+₹1.4 L (4.24%)Rejected-AOC | L4 | Rejected-AOC Awarded as forth lowest bidder (L4) | |
| 5 | L5₹36.0 L+₹2.5 L (7.32%)Rejected-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L5 | Rejected-AOC Awarded as fifth lowest bidder (L5) |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY INSIDE TECHNICAL AREA AT HEMRL UNDER GERD PASHAN PUNE
2021_MES_421437_1
GERD/PSN/TOKEN/39 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹70,000
Yes
30 Mar 2021
12 Feb 2021
11 Mar 2021
12 Feb 2021
8 Mar 2021
1 Mar 2021
12 Feb 2021 - 26 Feb 2021
60 days
Amount
CIVIL WORKS
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for taking out/laying of HT/ LT under ground cable and getting out in the following type of earth stata complete all as specified and as directed:- (a) Soft/loose soil
(b) Hard / dense soil
(c) Soft / disintegrated rock
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour dry crushed stone dust/ river sand filling in trenches to required width at bottom and top of cable cushioning including spreading leveling and consolidation completer all as specified and directed. Note : Punned thickness shall only be measured and paid.
Material and Labour in repairs for GI tube, light grade with all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection including removal old pipes all as specified for the following size of pipe :- NOTE :- (Excavation and earth work where required shall be measured and paid for separately. MS Clamps for fixing on wall / pole , etc are included in the unit rate). (a) 100 mm dia bore
(b) 80 mm dia bore
(c) 50 mm dia bore
(d) 40 mm dia bore
Material and Labour for disconnecting and taking out old LT ACB from LT panal board for servicing & overhauling LT ACB of any make 800 to 1600 Amp, 50Hz 415V AC Draw out type including taking out existing mechanism complete with servicing of operating machnism, triping mechanism and spring charging mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original position with all connections and testing complete all as specified and directed. Note : Major spare parts required to be replaced shall be measured and paid for separetly under respective item here in after, however cost of minor spares except mentioned in item Nos 14 to 17 below shall be deemed to be included in qouted rate.
Supply only following spare parts all as specified and directed :- a) Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories
b) Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB.
c) Under voltage tripping divice (UVT) 415 volts.
d) Single phae CTS at rating 800/5A.
Taking down old unserviceable MCCBs any capacity from existing LT panel board by disconnecting bus bar/incoming/out going cables complete all as specified and as directed including making good.
Supply and fixed MCCB 4pole, 400 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal-magnetic release type including making necessary connection complete all as specified and directed.
Supply and fixed MCCB 4pole, 250 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type including making necessary connection complete all as specified and directed.
Supply and fixed MCCB 4pole, 200 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal-magnetic release type including making necessary connection complete all as specified and directed.
Supply and fixed MCCB 3pole, 100 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type including making necessary connection complete all as specified and directed.
Supply and fixing MCCB 4 pole, 415 volts, termal magnetic adjustable type, 63 amps with breaking capacity 16 KA including making necessary connection complete all as specified and directed Note for item Nos 19 to 23: Minor addition alteration in panel required for fixing of above items are deemed to be included in the above quoted rates.
Supply and fixing in repair including testing and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor 1100 Volts grade in trenches/on wall/poles laid in duct/inside protection pipe of the following sizes including cables glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceiling/walls without cable duct including taking down old cables all as directed by Engineer-in-charge for the following cross sectional area cable :- Note :(i) Excavation and earth work, sand cushioning, brick protection will be measured and paid separately (ii) Cost of jointing material e.g. lugs, thimbles, nut bolt and washers shall be included in quoted rates. a) 300 sqmm 3.5 core.
b) 150 Sqmm 3.5 core.
c) 70 Sqmm 3.5 core.
d) 50 Sq mm 2 core.
e ) 16 Sq mm 4 core.
Supply and laying sub class B bricks, old size, laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable complete all as specified and directed.
Re-laying old serviceable bricks, old size, obtained from old cable laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable complete all as directed.
Material and Labour for Checking/megering of UG cable fault of any size/core and taking out the damaged portion of cable from trenches and removing the fault portion of cable and checking, jointing the same with proper cable end jointing kit and testing for smooth functioning of complete cable and re-laying the same after testing complete all as specified and directed. Notes : (i) Excavation/earth work/returning filling/relaying of brick and sand cushioning deemed to including the job. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item.
Material and Labour for straight through joint heat shrinkable type for UG cable including joint kit for making joint suitable for the following size complete all as specified and directed :- (a) 10 sq mm to 16 Sq mm, 2 core.
(b) 16 sq mm to 25 Sq mm, 4 core.
(c) 35 to 95 Sq mm, 3.5 core.
(d) 120 to 150 Sq mm, 3.5 core.
(e) 185 to 240 Sq mm, 3.5 core.
Supply and Fixing in repairs Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade including taking out existing unserviceable insulator all as specified and as directed.
Supply and Fixing in repair insulator shackle type, porcelain, vitreous, white, brown or green insulator including galvanised and mild steel straps of size 31x5mm, washers, insulator bolts, washers and nuts, size of insulator 100 mm height, 115 mm dia with 14 mm dia bolts for 1100 Volts grade including taking out existing insulators complete all as specified and as directed.
Material and Labour in repair for aluminium conductor steel reinforced for over head line, fixed on pole bringing the sag within limit, fixing to the insulator by means of necessary binding with 14 SWG aluminium wire including removal old complete all as specfied and directed.
Material and Labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour in repair for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and edequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe light grade for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection and removal old materials complete all as specified and directed.
Material and Labour in repair for Electrical Earthing with GI plate electrode of size 60 cm X 60 cm X 6 mm thick, burried directly in ground vertically ,erath pit not less than 2.25m deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 mtr below normal ground lelevel connected to GI strip earth lead of size 32 x 6 mm strip covered with 40mm dia bore GI pipe light grade by means of bolts, nuts,washers made of galvanised iron and connected to main control board /switch gear/ pannel boards all as specified and shown in Electrical plate No-3 of MES Schedule (SSR-2009) Part-I including necessery excavation and earth work in any type of soil,charcoal dust,salt and PCC 1:2:4 type B1 in chamber, RCC 1:2:4 type,B1 cover slab 40mm thick with 6 mm dia mild steel bars at 100 mm center to center both ways and with 6mm dia MS hook, 20mm dia GI pipe light grade for watering with wire mesh funnel, complete and testing resistence and removal old materials all as specified and as directed. Note for item No 39 & 40 : Earth continuity conductor beyond 7.5 metre shall be measured and paid for separately under relevant item here in after.
Material and Labour in repairs for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Material and labour in repairs for Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 32x6 mm size galvanised strip complete all as specified and directed.
Material and Labour for straight through joint,heat shrinkable,out door type for underground XLPE cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 sqmm,22 KV all as specified and directed. Make : M-Seal or equivalant as approved by GE.
Material and Labour for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV all as specified and directed by Engr-in-charge. Make : M seal or equivalant as approved by GE.
Material and labour for cutting the tree branches which touches the LT/HT OH lines and 2.5 mtr away from centre line of HT/LT OH line span not exceeding 60 mtrs between poles and deposting the tree branches/leaves at 30 m distance away from site complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
Material and labour on load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap complete all as specified and directed. Note: Oil samples are to be collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various cap installed in various locations complete all as specified and directed. Make of Transformer oil: Indian oil or equivalant as approved by GE. Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply & Fixed in repair of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Material and labour for repair to gang operated air brake switch device upto 400 Amps,22 KV capacity including greasing/oiling of all moving contacts,replacement of nut bolts,washers of suitable sizes,unserviceable spares and jumper connections in all phases for smooth functioning of the devices all as directed by Engr-in-charge. Note : Unserviceable spares and jumper connections required to be replaced will be measured and paid separately as "Supply only" under respective item here in after.
"Supply only the following items complete all as specified and duected :- (a) Male contact/moving contact with blade arcing hornof gang operated AB switch devices suitable for 22 KV
b) Female contact /fix contact jaw arcing horn for gang operated AB switch devices.
c) Tinned copper flexible jumper 200/200 Amps
d) Post top Polymer insulators of gang operated AB switch devices.
e) Middle post Polymer insulators of gang operated AB switch devices.
f) Bottom post Polymer insulators of gang operated AB switch devices.
g) MS jumper carrier.
h) Back connector plate.
Supply and fixing in repair GI pipe, heavy grade 25 mm dia made to shape for gang operating from ground complete all as specified and directed.
Material and labour for repair to drop out fuse complete of upto 400 Amps,22 KV capacity including replacement of worn out nut bolts,washers,of suitable size /unserviceabele spares and jumper connections for smooth functioning of the devices all as directed. Note : Unserviceable spares and jumper connections required to be replaced will be measured and paid seprately as "Supply only" under respective item here in after"
Supply only fix top contact/L contact for drop out fuse complete all as specified and directed.
Supply only fix lower contact for drop out fuse complete all as specified and directed.
Supply only Post insulators of drop out fuse complete all as specified and directed.
Material and Labour in repairs for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs as per site requirement encased with polythylene sleeve, RYB colour code of sitable current rating size complete all as directed for :- a) Not exceeding 0.75 metre length.
b) Exceeding 0.75 metre length but not exceeding 1.5 metre length.
c) Exceeding 1.5 metre length but not exceeding 2.5 metre length.
d) Exceeding 2.5 metre length but not exceeding 3.0 metre length.
Supply install testing and commissioning in repairs of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts heavelly tinned to withstand weather complete all as specified and directed. Make : Pactil/Surthern switch gear/Universal/BHEL/ELPRO
Supply & Fixed in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete all as specified and directed. Make : Pactil/Surthern switch gear/Universal/BHEL/ELPRO.
Supply & Fixed in repair Polymer Pin type insulator of 22 KV including necessary hardware complete all as specified and directed.
Supply & Fixed in repair Polymer disc type insulator, ball and socket type, white brown or green suitable for 22KV including necessary hardware complete all as specified and directed.
Material and Labour for preperation of old painted steel surface of following pole structure HT/LT street light/HT steel tublar poles above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering all as specified and directed for the following types:- a) HT 4 Pole structure 11 metre long
b) HT 2 Pole structure 11 metre long
c) HT pole 11 metre long
d) LT pole 8.5/9 metre long
Disconnecting the Pole mounted/platform mounted outdoor type transformer situated at various locations inside HEMRLsub station 22/ 0.433 KV 3 phase of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections including tap changer switch connection on all 3 phase, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer :- a) 50 to 100 KVA. Note : Winding wire required for rewinding & DP copper strip shall be measured and paid for separately as "supply only".
b) 150 to 200 KVA.
c) 250 to 315 KVA.
b) 400 to 500 KVA.
Supply only super enamelled copper winding wire (ISI marked) of various gauges or existing specifications for repair and rewinding of transformers under item No. 86 HT with insulation including necessary class of insulation as specified and directed.
Supply only DPC copper strip of various gauges or existing specifications (ISI marked) with insulation including necessary class of insulation as specified and directed. Make : ISI marked as approved by GE/Engr-in-charge.
Material and Labour for carrying out Lab test for acidity of Transformer oil for various Transformers at various locations and submitting test report on the format as directed by Engr-in-charge.
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 to 750 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed. Note : Defective parts required to be replaced will be measured and paid separately as "Supply only" under respective item here in after.
Supply only LT bushings with brass studs of existing specification complete all aspcified and directed.
Supply only top cover gasket set of existing specification complete all as specified and directed.
Supply only radiator flanged gasket 6 mm thick complete all as specified and directed.
Supply only oil level indicator gasket set complete all as specified and directed.
Supply only HT bushing with stud 22 KV of existing specification complete all as specified and directed.
Supply & Fixed in repair explosion vent diaphragm of suitable size to match with the existing complete all as specified and directed.
Material and Labour for preparation of old painted surfaces of transformer, removing rusted scale/oil & painting of transformer with one coat of synthetic enamel paint of approved make duly Marking/ Writting MES/SM No. complete all as specified and directed for the following:- (a) 50 to 100 KVA capacity of transformer.
(b) 160 to 250 KVA capacity of transformer.
(c) 300 to 500 KVA capacity of transformer.
Material and Labour for lifting of serviceable transformer of capacity 100 KVA to 500 KVA, 22/ 0.433 KV rated voltage, from one place to other by crane and transporting to other place within 02 Km radius including placing on plinth/pole mounting and connecting up all HT/LT connections, testing and energising the transformer complete all as specified and directed.
Material and Labour for disconnecting HT incoming/ Out going for servicing, opening, draw out VCB trolley complete from its position and through inspection of complete opearating mechnical system, electrical wiring system of AC/DC including tipping mechnisum, Commissioning of same after carryout following repair work and replacement of unserviceable spares/parts complete all as specified and directed by OEM :- (i) Checking of Draw out mechanism/arrangement of VCB (ii)Inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and replacement of worn out contacts if any. (iii) Checking of alignment with spout and setting of contact gaps. (iv) Replacement of worn out/defective minor spares parts, lubrication of moving parts of the truck by moly grease. (v) Checking/setting of master control relay, earth fault realy and overload realy. (vi) Also checking ON/OFF/TRIP indication and make it serviceable by necessary checking/repair/replacement of control wiring. (xiii) Decarburizing and reinsulation of complete busbar track system complete in all respect. (xiv) Misc works deemed essential to make VCB in perfectly working order. Note : Major spare parts listed here in under are to be paid separetly under respective items here in after, however cost of minor spares shall be deemed to be included in item rate.
Supply only spring charge motor single phase 110/220 volts complete all as specified and directed
Supply only Closing Coil 30V DC complete all as specified and directed.
Supply only Tripping Coil 30V DC complete all as specified and directed.
Supply only Top spout with Busbar 22 KV complete all as specified and directed.
Supply only Bottom spout with Busbar 22KV complete all as specified and directed.
Supply only Power pack complete all as specified and directed.
Supply only Push button for open and Close complete all as specified and directed.
Supply only Micro switches complete all as specified and directed.
Supply only Indication lamps complete all as specified and directed.
Supply only fingure jaw contact complete all as specified and directed.
Supply only Heaters 200 watts single phase 220 volts along with thermostat to be connected on existing wiring circuits complete all as specified and directed.
Supply only Non hygroscopic, track resistance, high strengh epoxy Bus supporting insulators 22 KV as per existing size and shape complete all as specified and directed
Material and Labour for primary / secondry current injection for testing of existing CT's set of three 60/5A capacity installed in VCB's and measuring meters located at different sites and providing authentic test results for further necessary action complete all as specified and directed.
Material and Labour for testing of 22 KV HT cable Hi-Pot (High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the UG XLPE cabling system for rectifying defects and rest report to be submitted complete all as specified and directed
Material and Labour for testing of 22 KV HT Hi-Pot (High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the over head lines system for rectifying defects and rest report to be submitted complete all as specified and directed.
Material and Labour for testing of 22 KV HT Hi-Pot (High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the HT structure 2/4/6 poles and its controlling system for rectifying defects and rest report to be submitted
Re-Stringing of HT/LT over head conductor and earth conductors, unwinding and visual testing of insulator, rewinding of ACSR and GI earth wire guard/ earth conductors rigidly with winding wire all as specified and directed.
Supply and Fixing in repairs Current Transformer suitable for 22 KV 50 Hz effectively earthed neutral system single phase dual core epoxy resin cast copper wound primery with rated burden 15 VA and accuracy class 1.0 and 5 to 10 for instrumentation and protection or better and conforming to IS 2705 (part - I & II) 1992, CT ratio 60/5A. The instrument security factor (ISF) shall be up to 5 and CT primary P1 & P2 terminal to be made in such a way that static voltages do not appear. the secondary of CT made robust design so as to provide effective and firm termination and resistance as low as possible with colour code on RYB complete duly intalled, commissioned, connected and tested at site complete all as specified and directed. Make : PRAGATI, PRAYAG, KAPPA, CROMPTON, AE, L&T, Vishal.
Supply, installation, testing and commissioning low maintenance type of Lead Acid tubular stationary battery 12 Volt 100 Ampere –hour complete all as specified and directed. a) Inter battery connector of lead plated copper of coss section not less than 50 sq.mm. b) Lead plated 2 nut bolts and 2 washers set Make : Exide, Autobat, Emaron or equivalent make as approved by GE.
Supply and Fixing in repair new generation energy saving environmental friendly LED street light /road way luminaries 70 watts not less than 6200 lumens pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fittings & connection on existing street light pole bracket complete all as specified and as directed. Make : Havells Cat No ENDURACITYLINEROSL 70WLED 757 PASYBOTG or Equivalent in make as specified in Appendix 'B' as approved by GE.
Supply and Fixing in repair new generation energy saving environmental friendly LED street light /road way luminaries 48 watts not less than 4200 lumens pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fittings & connection on existing street light pole bracket complete all as specified and as directed. Make : Havells Cat No ENDURA PEARLNEOSL 48WLED 757 PASYTOPC or Equivalent in make as specified in Appendix 'B' as approved by GE.
Supply and Fixing in repairs of street light bracket made out of 40mm dia medium grade GI pipe of 1.5 Mtr long bend to shape including single coat of aluminium pait over a coat of red primer painting complete all as specified and directed. NOTE:- MS clamp, nuts & bolts are measured and paid separately under item respective herein after.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 230mm x 170 mm x 105 mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for single phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron all as specified and directed. Make : Sintex or equvalant as approved by GE.
Material and Labour in REPAIR for 3 single core PVC insulated unsheathed copper conductor cable multistranded 2x 2.5 +1x1.5 sqmm passing through in steel pole DB to street light luminaires including removal old complete all as specified and directed NOTE :- 3 run of wire shall be measured as one length
Supply and fixing in replacement Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 8 kW single-Phase load .Contactor Rating: 40.Amps ( 2-pole ).MCB (single-pole) Rating:63.Amps (2 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider or equivalent, MCB: Hager/Schneider/Legrand/L&T. Make:SWADEEP – 02EC 8kW1P or equvalant as approved by GE.
Supply and fixing in replacement Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kW load equally distributed over 3-phase .Contactor Rating: 40.Amps (4-pole).MCB (single-pole) Rating: 40.Amps (3 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T Make:SWADEEP – 02EC 12kW3P or equvalant make as specified in appendix 'B' as approved by GE.
Suply and fix in repair potential Transformer of rating 1RT3/110V/RT3, 22 KV pressure epoxy cast resin complete duly intalled, commissioned, connected complete all as specified and directed.
Suply and fix in repairs single element master trip relay, Aux supply 30V DC having 5 Nos of contact either 4 No + 1 Nc or 3 No + 2 Nc, Hand rest contact with hand reset Flag type B24 type relay. Make : EASUN REYROLLE and AVANA ELECTROSYSTEM complete all as specified and directed
Supply and fixing in repairs 5 Amp to 20 Amp complete all as specified and directed 22 KV HT Drop out fuse complete all as specified and directed
Supply and fixing in repairs 25 Amp to 40 Amp complete all as specified and directed 22 KV HT Drop out fuse complete all as specified and directed
Supply and fixing in repairs 50 Amp to 60 Amp complete all as specified and directed 22 KV HT Drop out fuse complete all as specified and directed
Supply and fixing in repairs industrial switchgear busbar chembers suitable for 415 Volts of capacity 100 Amps 4 way completed all as specified and directed. Make : Havells/legrand/Standard.
Supply and fixing in repairs low loss electromagnetic energy efficient, low heat genertion, high power factor ballast 400 watts MH consisting high quality silicon steel lamination with argon welding, super enameled copper wire, vacuum impregnated with white resin, terminal block with tapping for 240 volts 50 HZ supplied suitable for revolving type search lighting applications including inbuilt capacitor 16 MFD and ignitercircuit including removal old complete all as specified and directed.
Material and labour for painting of existing LT panel of exposed out side surface area with one coat of synthetic enamel paint after prepration of surface with spray painting complete all as specified and directed.
Surface excavation in hand/dense soil complete all specified and directed not exceeding 30 cm in depth and averaging 75 mm deep complete all as specified and directed.
Material and Labour in repairs for spreading stone aggregates/hardcore of gauge not exc. 40mm, deposited, spread and levelled in layers not exc. 15 cm thick including levelling, watering and ramming to a true surface complete all as specified as directed by Engr-in-charge.
Material and labour for repairing the existing LT Panel up to 400 AMP Capacity by welding the damaged hinges/aligning the doors to fit properly including providing rubber gasket and locking arrangement complete all as specified and directed.
Material and labour for repairing the existing LT Panel above 400 AMP Capacity by welding the damaged hinges/aligning the doors to fit properly including providing rubber gasket and locking arrangement complete all as specified and directed.
KESARI AND SONS
R. K. Industrial Fabricators
MAYUR ELECTRIC SERVICES
Sunil Constructions
SKS Electricals
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .