| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹42.4 L+₹2.6 L (6.52%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹44.0 L+₹4.2 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹45.0 L+₹5.2 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Chinmaya Enteprises L1 | SONA LAKSHMI ASSOCIATE L3 | JAYESH ASSOCIATE AND DEVELOPERS L4 | M/S. ELECTROPOWER TECHNOLOGIES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in soft/loose soil and getting out for taking down/laying of cables of any description and in any position, complete all as specified and directed. | 208.98 | Cum | 240 ₹50,155.2 | 280 ₹58,514.4 | 28 ₹5,851.44 Lowest | 295 ₹61,649.1 |
| 2.00 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 198.53 | Cum | 60 ₹11,911.8 Lowest | 70 ₹13,897.1 | 95 ₹18,860.35 | 100 ₹19,853 |
| 3.00 | Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point.complete all as specified and directed | 10.45 | Cum | 60 ₹627 | 80 ₹836 | 55 ₹574.75 Lowest | 100 ₹1,045 |
| 4.00 | Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed. | 860 | RM | 25 ₹21,500 Lowest | 40 ₹34,400 | 175 ₹1,50,500 | 40 ₹34,400 |
| 5.00 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | 460 | RM | 270 ₹1,24,200 Lowest | 290 ₹1,33,400 | 620 ₹2,85,200 | 280 ₹1,28,800 |
| 6.00 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | 80 | RM | 405 ₹32,400 Lowest | 430 ₹34,400 | 875 ₹70,000 | 425 ₹34,000 |
| 7.00 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | 100 | RM | 595 ₹59,500 Lowest | 620 ₹62,000 | 710 ₹71,000 | 625 ₹62,500 |
| 8.00 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | 220 | RM | 1,250 ₹2,75,000 | 1,290 ₹2,83,800 | 989 ₹2,17,580 Lowest | 1,275 ₹2,80,500 |
| 9.00 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | 40 | RM | 2,190 ₹87,600 | 2,240 ₹89,600 | 1,950 ₹78,000 Lowest | 2,200 ₹88,000 |
| 10.00 | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole & other connected accessories complete all as specified and directed. | 513 | RM | 80 ₹41,040 Lowest | 85 ₹43,605 | 175 ₹89,775 | 80 ₹41,040 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Apr 2026, 6:00 pmClosed
Garrison Engineer
Military Engineer Services, Garrison Engineer, Cantt Area, Kamptee 441001
COMPERHENSIVE MAINT OF EXTERNAL ELECTRIC SUPPLY, REPLACEMENT OF LT PAOLES, CABLES, LT PANELS ETC AND CONNECTED ITEMS AT FORT AREA NAGPUR AT FORT AREA UNDER GE KAMPTEE.
2026_MES_756942_1
8899/E8
Open Tender
Civil Works
Item Rate
180 days
Nagpur
All as per NIT
8 documents required · 8 mandatory
₹500
GE Kamptee
₹80,000
Yes
30 Apr 2026
19 Mar 2026
11 Apr 2026
19 Mar 2026
9 Apr 2026
2 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in soft/loose soil and getting out for taking down/laying of cables of any description and in any position, complete all as specified and directed. | - | Cum | - | - |
| - | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | - | Cum | - | - |
| - | Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point.complete all as specified and directed | - | Cum | - | - |
| - | Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed. | - | RM | - | - |
| - | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | - | RM | - | - |
| - | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | - | RM | - | - |
| - | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | - | RM | - | - |
| - | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | - | RM | - | - |
| - | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 Core, ISI marked as per IS 7098 (Part-I) in trench/floor/on pole/wall complete all as specified and directed. | - | RM | - | - |
| - | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole & other connected accessories complete all as specified and directed. | - | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_847879.xls
BOQ • 0.68 MB
Tenderdocument8898.pdf
Tender Documents • 0.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .