Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC Valid | |
| 2 | L2₹53.2 L+₹7.5 L (16.5%)Rejected-Finance | L2 | Rejected-Finance Being not found lowest | |
| 3 | L3₹53.4 L+₹7.7 L (16.8%)Rejected-Finance H NO 670 SECTOR 10 PANCHKULA HRY 134115 | PANCHKULA | HARYANA | 134115 | L3 | Rejected-Finance Being not found lowest | |
| 4 | L4₹54.4 L+₹8.7 L (19.1%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Being not found lowest |
Tender Value
₹50.0 L
EMD Value
₹99,940
Closing Date
7 Apr 2022, 6:00 pmClosed
GE (AF) SURATGARH
GE (AF) SURATGARH
REPAIR TO TOILET BATHROOM AND SANITARY FITTING IN SMQ AREA SINGLE LINE ACCN INCLUDING LEAKAGE SEAPAGE (AKASH VIHAR) AND FLOORING PLASTRING PLINTH PROTECTION AND OTHER MISC BR WORK AT AF STATION SURATGARH
2021_MES_498630_3
8929/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
As per tender documents
10 documents required · 10 mandatory
₹500
Yes
GE (AF) SURATGARH
₹99,940
Yes
20 May 2022
17 Mar 2022
9 Apr 2022
17 Mar 2022
7 Apr 2022
24 Mar 2022
Amount
BOQ (REPAIR TO TOILET, BATHROOM AND SANITARY FITTING IN SMQ AREA SINGLE LINE ACCN INCLUDING LEAKAGE SEAPAGE (AKASH VIHAR) AND FLOORING, PLASTRING, PLINTH PROTECTION AND OTHER MISC B/R WORK AT AF STATION SURATGARH)
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for cement concrete 1:5:10 type E-2 using 40mm graded stone aggregates as in filling of sunken floors complete all as specified & directed.
M&L applying for Dr. Fixit bathseal system over the sunken portion floor of bathroom , with the products in the "Kit' as details below ( Work Shall be carried out by only authorized applicator ) (i ) Dr. Fixit bathseal 2K WPC - Acrylic elastomeric cementitious waterproof coating for sunken portion Floor and walls in bathroom. Note:- In the case of non execution of work within 3days after demolition of sunken portion of toilet recovery will be effected 1000 Rs per day .
M&L for 25 mm thick PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) as in flooring on roof with smooth surface finished, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11 but n.exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 , complete all as specified and directed by Engr-in-Charge
M&L for Glazed colour ceramic tiles in vertical surface 450mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge
M&L for swimming pool tiles at finished plain surface of size 247mm x 122mm x 8mm of approval colour and design. The pool tiles to be fixed on the floor/wall surface with the help of approved adhesive applied at the rate of 2.5 kg/Sqm and grouting of the same. The quoted rate shall be inclusive of all complete all as specified and directed by Engr-in-Charge (i) MYK LATICRETE USED AS ADHESIVE FOR FIXING OF TILE. (ii) MYK LATICRETE SP-100 USED AS EPOXY FOR GROUTING OF TILE. (Make : Johnson Endura Note: Location : Swimming pool of Maru Vihar. Make : Johnson (Endura) / Kajaria / Orient bell
Taking up or down 15mm steel water tubing and connection incl cleaning for refixing or removal to stores, complete all as specified and directed.
Taking up or down 20mm steel water tubing and connection incl cleaning for refixing or removal to stores, complete all as specified and directed.
Supplying and laying of 20mm outer diaCPVC pipes SDR 11 and plain CPVC SDR 11 including necessary fitting (Brass elbow, Brass Tee, Union) on walls/ceiling or laying in floors, complete all as specified and directed by Engr-in-charge.
S&F 20mm GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Re-fixing steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified and directed.
Supplying and laying of CPVC 40mm outer dia pipes SDR 11 and plain CPVC SDR 11 for disposal of washing machine waste water disposal including clamping of pipe on wall with GI clamp complete as as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit writing etc and making good, cutting not exc 10cm girth, complete all as specified and directed.
S&F 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets in repair, complete all as specified and directed.
S&F Vitreous China Squatting pan, 'Orissa' pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) in repair, complete all as specified and directed.
S&F Vitreous China wash down water closed pan (Pedestal pattern) white , including connection to drain(or out going pipe) and to flush pipe, antisypthonic (excluding flushing cistern and flush pipe) in repair, complete all as specified and directed.
S&F in repair of stainless steel sink, 1.00 mm thick for kitchen or laboratory with plug, waste pipe, washers, including bedding in cement mortar on to dwarf wall, including mild steel brackets, connecting union etc to pipe,overall size 495 x 420mm bowl size 410mm x 330mm x 160mm etc, complete all as directed
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm , complete all as specified and directed.
S&F 15mm Cast copper alloy, Bib taps fancy type chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed in repair, complete all as specified and directed.
S&F 15mm Stop valve fancy type chromium plated screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed in repair, complete all as specified and directed.
S&F in replacement of 15mm dia PVC connection 450 mm long,complete all as specified and directed.
S & F 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed.
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms), complete all as specified and directed.
S&F Stainless steel grating 125mm dia fixed in repairs , complete all as specified and directed.
S&F Wash hand basins, vitreous china, white, flat back of size 550x400 mm with pedestal including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new brackets fixed , complete all as specified and directed by the Engineer in Charge.
S&F in repairs 100mm bore UPVC (SWR) Type'B' (SCH -40), fixed to wall or laid in trenches / in floors with all fittings (bend, Tee and Branch piece) and fixtures , complete all as specified and directed.
S&F in repairs 75mm bore UPVC (SWR) Type'B' (SCH -40), fixed to wall or laid in trenches / in floors with all fittings (bend, Tee and Branch piece) and fixtures, complete all as specified and directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent floor trap, including jointing to waste pipe fixed in repair, complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls including raking out joints/hacking for key, scrubbing down with water etc complete all as specified and as directed by Engr-in-Charge
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces finishing even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surfaces finishing even and smooth without using extra cement complete all as specified and as directed by the Engr-in-Charge
Preparation of new plastered or un plastered wall surfaces of any description, applying two coats of distemper oil emulsion over a coat of Chalk whitening primer, complete all as specified and directed by the Engineer-in-Charge
Applying two coats of exterior acrylic emulsion (weather proof treatment), in camouflaging patterns , including preparation over new plastered surfaces complete all as specified and directed.
S&F in repairs gun metal, globe or gate valve with iron wheel, screwed both ends for iron pipe suitable for 20 mm bore iron pipe, complete all as specified and directed.
Dismantling existing water storage tanks exc 250 litres but n.exc 500 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and directed by Engineer-in-Charge
S&F Rotational moulded PVC, white colour, tripple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve , complete all as specified and directed by Engineer –in-Charge.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area n exc 1.50 Sqm and removal from site, complete all as specified and directed.
Supply & fix in repairs , stainless steel Plate Rack of best quality, made out of 0.80 mm thick stainless steel sheet , of size 90 cm x 60 cm x 25 cm with all internal fittings of appoved make , complete all as specified and directed.
S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications and drawing, complete all as specified and directed.
S&F Factory made solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification & drawing, complete all as specified and directed.
S&F 100 mm mild steel butt hinges medium weight cold rolled, complete all as specified and directed.
S&F 150mm long,aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm size aluminium handles,cast type,anodised, complete all as specified and directed.
Excavation in trenches in soft/loose soil, n exc 1.5m wide and n. exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated soil exc 250m but not exc 500m and depositing where directed at a level n. exc 1.5m above the starting point, complete all as specified and directed.
Demolition of 150 mm bore SGSW AC drain pipes, with PCC haunching jointed in cement mortar and taking out of trenches if required and removal of existing sludge, complete all as specified and directed by the Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in bed with thickness of bed below the barrel of pipe as 100mm and width of bed as 450mm to drain pipes of 150mm internal dia including packing under, and completely surrounding pipes with concrete after they are laid and tested complete all as specified and as directed by Engr-in-Charge
M&L for salt glazed stoneware drain pipes 150mm internal dia laid in trenches and jointed, complete all as specified and as directed by Engr-in-Charge
Cutting into existing Manholes for connecting new drains , 150mm dia, making good to pipes and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and as directed by Engr-in-Charge
S&F factor made steeel windows box type with side hung shutter fabricated out of cold refuced low carben steel sheeet of designation CR2, grade D as per IS 513:2008 including following components / specification, complete all as specified and directed by Engr-in-Charge. (i) Two/Single (As per site requirement) leaf glazed shutter and two / single (As per site requirement leaf gauged (fly profing) shutter. (ii) Pressed steel window frame double rebate. (iii) Grill of 8 mm MS square bar @150 mm c/c (vertical spacing) through out outer frame to outer frame. (iv) MS box hinges, stay, latch, handle, Tower bolt. (v) Flat iron for hold fasts fillets for fixing wire mesh (vi) All section made of CRLCS sheet 1.25 mm thickness for outer frame/mullion/transomsand. 1.00 mm thickness for shutter frame size / shape of all section as specified in drawing. Note : Supply & fixing of sheet glass and wire mesh shall be measured and paid separately.
M&L Machine pressed precast concrete interlocking paver block any shape ad size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigments including 25 mm thick sand cushion complete all as specifieed & directed. Make : Nitco / Chopdar / Mehtab Tiles
S&F 50 mm wide Ailanto, wooden venetian blinds are made of fine-grained bass wood available in natural colours completed all as specified and directed by Engr-in-Charge. Make : Vista/Marvel/Hunter Douglas
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples , complete all as specified and directed.
S&F 3 mm thick plain sheet glass ordinary quality & glazing with oil putty in square n exc 0.50sqm in each pane, complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide, zinc chrome primer to iron and steel surfaces of any description, not otherwise described over 10cm width or girth including preparation of new steel surfaces, complete all as specified and directed.
Demolition of RCC of any description in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition), complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in manhole covers set in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips , complete all as specified and directed.
S&F, Bib tap standard of PTMT ,15mm bore dia of any colour high pressure screwed for iron pipe and fixed as in repair (minimum weight 90gms) ,complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on and inclusive PVC sheet fillet of width 35mm PVC frame as complete all as specified and directed.
M&L for cement concrete Type C2 1:3:6 (40 mm graded aggrete) as in plinth protection/paving finished fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge.
S & F in repair 110 mm bore PVC (SWR) Soil, waste and rainwater pipes single socketed in any length with rubber ring joints fixed to walls.,complete all as specified and directed by Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) bends of any radius,complete all as specified and directed by Engineer-in-Charge.
Demolition of false ceiling of any description, any thickness including cover fillets and frame work complete all as specified and directed by the Engr-n-Charge
M&L for exposed GI frame/grid system duly powder coated for module size of 600 x 600 mm suitable for lay-in aluminium / mineral fibre ceiling tiles, having main T runner of 24 mm size, suspended at 1200mm C/C and cross T runner of 24 mm size, suspended at 600mm C/C with interlocking arrangements to form grid of 600 x 600mm, perimeter runner/channel of 15 mm size, main and cross T runner supported by 4mm dia GI rod from slab / Roof, wall angle etc with and including all fixing accessories and making good to distrubed wall surfaces , as required to match the existing surfaces, ,complete all as specified and directed by Engineer-in-Charge.
M&L for metal false ceiling, lay-in type, 0.5 mm thick, having tegular edge profile, duly powder coated, perforated type suitable for false ceiling grid/frame module of 600 x 600mm size,complete all as specified and directed by Engineer-in-Charge. (Note : The grid /frame shall be measured and paid for separetly.)
Cleaning of Grease trap tank by taking out the sludge mud/silt etc and removing to outside of MOD premises complete all as specified and directed by Engr-in-Charge.
De-watering of septic tanks/soakage wells and sewage line by pumping with trolley mounted pump sets including carrying the waste water in closed containers and unloading it out side the MoD land at location shown by Engr-in-Charge at a distance n. exc 5 km from the starting point including removing the existing manholes cover and replacing the same, septic tanks/soakage wells of any size/depth complete all as specified and as directed by the Engr-in-Charge Note:- (1) Hydraulically driven high pressure pump, capacity of 295L/min at 135 bar. (2) Hydraulically driven high pressure pump, having 1850 cum/hr Suction Pressure. (3) Rear hydraulic driven hose reel with 120m jetting hose. (4) proper safety of the operator during operation.
S&F Vitrified Ceramic tiles Light shade 10mm thick( square/rectangle) Polished area of each tile exc 0.42 sqm but not exceeding 1.00sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
GARG ENTERPRISES
IMPERIAL ENGINEERS
M/S Shree Ram Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .