GE 881 EWS
GE 881 EWS C/o 56 APO
GE/PNH-21/2020-21
2020_MES_379760_1
GE/PNH-21/2020-21
Open Tender
Civil Works
Lump-sum
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹32,000
Yes
19 Feb 2021
22 Sept 2020
23 Nov 2020
22 Sept 2020
21 Nov 2020
13 Oct 2020
60 days
Amount
Schedule 'A' Part-I (Building Work) JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block) & SHQ/POONCH/REV-05/2020-21 (Toilet block)
Total amount of Sch 'A' Part-I (Building work) brought forward from srl page No-19.
Schedule 'A' Part-II (Internal Water Supply works) JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block) & SHQ/POONCH/REV-05/2020-21 (Toilet block)
Total amount of Sch 'A' Part-II(Internal Water Supply works) brought forward from srl page No-21
Schedule 'A' Part-III (Plumbing works) JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block) & SHQ/POONCH/REV-05/2020-21 (Toilet block)
Total amount of Sch 'A' Part-III(Plumbing works) brought forward from srl page No-22
Schedule 'A' Part-IV Sec-I (Internal Electrification works) JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block) & SHQ/POONCH/REV-05/2020-21 (Toilet block)
Total amount of Sch 'A' Part-IV Sec-I (Internal Electrification works) brought forward from srl page No-24
Schedule 'A' Part-IV Sec-II (Internal Electrification works) JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block) & SHQ/POONCH/REV-05/2020-21 (Toilet block)
MCB single pole and neutral 40 Amps 240 volts 10 KA 'C' series all as specified. Make:- Havells cat part No-DHMGCSNF040 or Equivalent cat part of make of make:- Legrand /Indoasian.
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or equivalent cat part of make-Legrand / INDOASIAN / L&T
Heavy duty exhaust Fan 300mm sweep 1400 RPM, single phase 240 Volts AV 50Hz including all connecting accessories, complate all as specified and directed. Make:- Crompton cat part No-EXHD300-4-1 or Equivalent cat part of make of make:-Havells / Bajaj.
LED lamp ADORE 10 watt with holder base (B22) type & 5star rating, 1200mm lumen outputcomplete all as specified. Make of LED lamp:- Havells cat part No-LHLDEUEBML8Z010 or Equivalent cat part of make:-Wipro / Crompton / Bajaj / cropmpton
Tube light fitting with universal batten suitable for T8 LED lamps LED 20W tube Rod with end cap complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20LED tube rod 4 feet long (Double Side Connection) fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-REGALBATTENT8UPTO1X22WSSBSWH for fittings & CRYSTAL 1213T8DSTL20WLED865SGLASS for LED tube rod or Equivalent cat part of make as specified in Appx 'A' here in after. Note :- The LED batten and LED tube rod shall be of same make.
Schedule 'A'Part-V (Sewage Disposal Works) JOB NO. SHQ/POONCH/REV-01/2019-20 (Toilet block)
Total amount of Sch 'A' Part-V(Sewage Disposal WorKs) brought forward from srl page No-26
Schedule 'A'Part-VI(External water supply Works) JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block) & SHQ/POONCH/REV-05/2020-21 (Toilet block)
Total amount of Sch 'A' Part-VI(External water supply Works) brought forward from srl page No-27
Schedule 'A'Part-VII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.(JOB NO. SHQ/POONCH /REV-04/2019-20 (Toilet with bathroom block), SHQ/POONCH/REV-05/2020-21 (Toilet block), SHQ/LBW-01/2020-21(Provn of 1 x 62.5 KVA DG set) & SHQ/POONCH/MINOR/02/2020-21(Provn of open shed).
B&R Portion:- Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, complete all as specified.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation of poles and mass concrete, complete all as specified.
Steel work in tubular trusses, column etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
0.63mm thick galvanised corrugated mild steel sheeting with grade of Zinc coating of 275 gms/Sqm with two corrugation side lap and at least 150 mm end lap , fixed with L or J type or cranked hook bolts, in roof, walls etc, complete, all as specified.
Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
100mm thick PCC 1:1.5:3 type A-2 (using 40mm graded crushed stone aggregate) as in floor, path, road, hardstanding etc, finished the surface even & fair, complete all as specified
Removing excavated material (soil) not exceeding 50m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
Prime Mover : Prime mover suitable for driving alternator 62.5 KVA Capacity having the suitable BHP at 1500 RPM for rated output for alternator in accordance with latest BS/IS Specification with electric starting device with all standard fittings and suitable capacity of lead acid maintenance free battery of 12 Volts 180AH -01 nos with Battery and Charger Engine over speed safety mechanism shall be incorporated. The engine shall be equipped with standard fittings as per manufacture's recommendations.
Engine Control Panel : (a) All relevant parameters shall be conventionally displayed on complete panel thereby providing easy monitoring of lub oil, pressure, Coolant Temperature, Battery charging, Ammeter, RPM, Hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Main and DG Both supply, internal wiring and power contactors suitable for 62.5 KVA generator set, all as per manufacturer's recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as per manufacturer recommendation and CPRI Approved & as per relevant IS.
Fuel Tank : Fuel Tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary pipe connections from fuel tank to engine and over flow from engine to tank.
Engine Alternator 62.5 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class 'H' continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requirement. The output of alternator not less than 62.5 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL. Note:- (a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor. (b) Extenssion of exhaust pipe for DG set along with standerd accessories like flange, nut bolts , asbestous rope etc shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor. (c) Cost of foundation and necessary civil works as per the manufacturer's recommendations/site requirement shall be incuded in the unit rate quoted by the contractor.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron earth lead strip 32x6mm by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 40mm bore including GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including taking down old unsv earthing, complete all as specified and directed.
Supply laying testing cable XPLE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty 1100 volts grade, with stranded aluminium conductor of size 150 Sqmm 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for laying of cable or any work as directed & getting out in any type of soil, complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each, complete all as specified and directed
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed.
Sand cushioning to under ground cable providing with a layer of08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment).
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Provn of construction of platform suitable for 62.5 KVA Generator set/ Voltage stabilizer of size 4.0m x 2.0m x0.6 m (Platform shall be made out of brick masonary one feet below ground level and one feet above ground level all around & hollow space inside the brick wall to filled by PCC 1:3:6 type C-2 watered and well rammed with & including 100mm thick cement concrete 1:2:4 type B-2 as in floor of platform, plastering in CM 1:4 complete all as specified and directed.
M/S SV CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .