Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹31.8 L+₹4.4 L (16.2%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹33.7 L+₹6.4 L (23.5%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹34.4 L+₹7.1 L (25.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 bidder | |
| 5 | L5₹37.3 L+₹10.0 L (36.4%)Rejected-Finance 1040 12 3 BABA KARAM CHAND STREET NEAR MAHANTA DI KOTHI DORAHA 141421 DISTT LUDHIANA PB | DORAHA | LUDHIANA | PUNJAB | 141421 | L5 | Rejected-Finance Being L5 bidder |
Tender Value
₹30.7 L
EMD Value
₹61,400
Closing Date
17 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_619577_1
GE(S)/PAT/T-41/N/2023-24
Open Tender
Civil Works
Item Rate
210 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹61,400
Yes
23 Nov 2023
19 Sept 2023
19 Oct 2023
19 Sept 2023
17 Oct 2023
3 Oct 2023
19 Sept 2023 - 25 Sept 2023
Amount
Supply, installing and testing of Refrigerator, electric driven 230 Volts, Single Phase, 50 Hz, Capacity 155 Litres BEE 5 star rated, energy efficient compreesor, single door type, working on R-600a or environment friendly refrigerent, Interior Lamp, Shelf Type with Toughened Glass, puf insulated body having Vegetable & Fruit Drawer, water bottle tray, top freezer complete all as specified and directed by Engr-in-Charge. (Note :- Capacity of refregerator will be enhanced if 155 Ltr not manufactured/available and quoted rate will be apllicale for the same).
Supply, installing and testing of Refrigerator, electric driven 230 Volts, Single Phase, 50 Hz, Capacity 200 Litres BEE 5 star rated, energy efficient compreesor, single door type, working on R-600a or environment friendly refrigerent, Interior Lamp, Shelf Type with Toughened Glass, puf insulated body having Vegetable & Fruit Drawer, water bottle tray, top freezer complete all as specified and directed by Engr-in-Charge. (Note :- Capacity of refregerator will be enhanced if 200 Ltr not manufactured/available and quoted rate will be apllicale for the same).
Supply, installing and testing of Refrigerator, electric driven 230 Volts, Single Phase, 50 Hz, Capacity 250 Litres BEE 5 star rated, energy efficient compreesor, double door type, working on R-600a or environment friendly refrigerent, Interior Lamp, Shelf Type with Toughened Glass, puf insulated body having Vegetable & Fruit Drawer, water bottle tray, top freezer complete all as specified and directed by Engr-in-Charge. (Note :- Capacity of refregerator will be enhanced if 200 Ltr not manufactured/available and quoted rate will be apllicale for the same).
Supply, installing and testing of Refrigerator, electric driven 230 Volts, Single Phase, 50 Hz, Capacity 265 Litres BEE 5 star rated, energy efficient compreesor, double door type, working on R-600a or environment friendly refrigerent, Interior Lamp, Shelf Type with Toughened Glass, puf insulated body having Vegetable & Fruit Drawer, water bottle tray, top freezer complete all as specified and directed by Engr-in-Charge. (Note :- Capacity of refregerator will be enhanced if 265 Ltr not manufactured/available and quoted rate will be apllicale for the same).
Supply, installing and testing of Refrigerator, electric driven 230 Volts, Single Phase, 50 Hz, Capacity 290 Litres BEE 5 star rated, energy efficient compreesor, double door type, working on R-600a or environment friendly refrigerent, Interior Lamp, Shelf Type with Toughened Glass, puf insulated body having Vegetable & Fruit Drawer, water bottle tray, top freezer complete all as specified and directed by Engr-in-Charge. (Note :- Capacity of refregerator will be enhanced if 290 Ltr not manufactured/available and quoted rate will be apllicale for the same).
Supply, installing and testing of Refrigerator, electric driven 230 Volts, Single Phase, 50 Hz, Capacity 300 Litres BEE 5 star rated, energy efficient compreesor, convertible technology, double door type, working on R-600a or environment friendly refrigerent, Interior Lamp, Shelf Type with Toughened Glass, puf insulated body having Vegetable & Fruit Drawer, water bottle tray, top freezer complete all as specified and directed by Engr-in-Charge. (Note :- Capacity of refregerator will be enhanced if 300 Ltr not manufactured/available and quoted rate will be apllicale for the same).
Supply, installing and testing of Deep freezer, single phase 230 volts, 50 Hz, metal hard top 320 litre capacity having double door, BEE 5 Star rating, energy efficient compreesor, convertible technology, working on R-134a or environment friendly refrigerent, Interior Lamp complete all as specified and directed by Engr-in-Charge.
Supply, installing and testing of Deep freezer, single phase 230 volts, 50 Hz, metal hard top 400 litre capacity having double door, BEE 5 Star rating, energy efficient compreesor, convertible technology, working on R-134a or environment friendly refrigerent, Interior Lamp complete all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and directed by Engr-in-Charge.
M&L for Sub main wiring in PVC casing caping/conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 2.5 sqmm multistrand and 2.5 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble complete all as specified and directed by Engr-in-Charge. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) If Necessary cutting chasing shall be included in this item.
M&L for Sub main wiring in PVC casing caping/conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 4 sqmm multistrand and 4 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble complete all as specified and directed by Engr-in-Charge. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) If Necessary cutting chasing shall be included in this item.
Supply & Fix of modular type, switch socket combination, 6/16 Amps, complete all as specified including metal box, cober plate etc complete all as specified and directed by Engr-in-Charge.
Supply & Fix of modular type, switchsocket combination, 6/20 Amps, complete all as specified including metal box, cober plate etc complete all as specified and directed by Engr-in-Charge.
Supply & fix exhaust fans metal body AC single phase 230/ 240 V of size 230/250 mm sweepwith, blades, frame and louvers including providing copper twin core wire upto ceiling rose for connecting of exhaust fan complete all as specified and directed by Engr-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, frame and louvers including providing copper twin core wire upto ceiling rose for connecting of exhaust fan complete all as specified and directed by Engr-in-Charge.
Supply & fix exhaust fans metal body AC single phase 230/ 240 V of size 380 mm sweep with, blades, frame and louvers including providing copper twin core wire upto ceiling rose for connecting of exhaust fan complete all as specified and directed by Engr-in-Charge.
Supply & fix exhaust fans metal body AC single phase 230/ 240 V of size 450 mm sweep with, blades, frame and louvers including providing copper twin core wire upto ceiling rose for connecting of exhaust fan complete all as specified and directed by Engr-in-Charge.
M&L for cutting/drilling of wall of in round/square shape as per site requirement for fixing of Exhaust Fan 230/300 mm sweep including making good the distubed surface by plaster and matching with existing colour complete all as specified and directed by Engr-in-Charge.
M&L for cutting/drilling of wall of in round/square shape as per site requirement for fixing of Exhaust Fan 380/450 mm sweep including making good the distubed surface by plaster and matching with existing colour complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable (multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job.
Supply & Fix modular switch 1 way, 6 Amps, 1 module complete all as specified and directed by Engr-in-Charge..
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. 5 Star rated with brushless direct current motor (BLDC). Unserviceable ceiling fan will be deposited to MES store and complete all as specified and directed by Engineer-in-Charge.
Ditto but of size 1400 mm with Min Air delivery 245 CFM and service value 6.0 Unserviceable ceiling fan will be deposited to MES store and complete all as specified and directed by Engineer-in-Charge.
Supply, install, test and commissioning of silent type Diesel engine driven Generation set of capacity 40 KVA/32 KW, 3 Phase, 415 Volts, 50 Hz, at 0.8 pf(lag) with Diesel engine, Alternator and control panel all mounted in acoustic enclosure including Catalytic Converter for emission control etc complete confirming to the detailed specifications as given below:-
Diesel Engine: The diesel engine shall be of capacity suitable for alternator of capacity 40 KVA/32 KW developing required power for rated KVA not less than 28.8 KW at 1500 RPM, 6 Cylinders in-line, 4 stroke, radiator cooled, continuous duty with 10% overload capacity for any one hour in 12 hours of continuous running and consisting of following:- a) Radiator cooled b) electrical Starter Motor 12V DC. c) 1No x 12 V battery, 180 AH rating with connecting leads and terminals. d) Battery Charging Alternator e) Fuel System with electronic governor f) Full flow spin-on lube oil filter g) Duel fuel filter with water separator h) Residential type silencer j) Dry type air cleaner k) Fly wheel and fly wheel housing I) First fill of lube oil & Coolant.
Alternator : -The Alternator shall be capacity 40 KVA/ 32 KW, 415 Volts, at 0.8 pf(lag,) 50 Hz, 3 phase, 4 wire system, suitable for operation at 1500 RPM. The Alternator shall be brushless type screen protected, revolving field, self excited, self regulated through an AVR, copper wound, Class ‘H’ insulation, having +1.0% voltage regulation (max) in static conditions and continuous duty operation.
Mounting Arrangement :- Engine and Alternator shall be mounted on a common MD fabricated base frame with Anti Vibration Mounting Pads.
Fuel Tank :- Integral fuel tank shall be of capacity not less than 90 Liters and provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.
Acoustic Enclosure :- the entire generator, prime mover, fuel tank and DG set control panel should be housed in a sound proof acoustic enclosure made of CRCA sheets with UV resistant powder coated and a structural/sheet metal base frame. The walls of the enclosure should be insulated with high quality noise absorbent and fire-retardant grade acoustic insulation material complying to IS-8183 for better sound attenuation so as to comply with 75 DBA at 1 meter sound levels at 75% load under free field conditions as specified by MOEF/CPCB. The enclosure should be provided with the following.- (i) Suitable doors on all sides to enter in to the container for easy maintenance. All doors shall be provided with licks and handles for opening/closing of doors. (ii) suitable internal lighting to carry out easy inspection and maintenance. (iii) Air Intel louvers designed to operate at rated load. (iv) Fluid filling point with licking arrangement (v) Fuel filling point with licking arrangement. (vi) Push button for emergency stop.
Note for item No. 26 :- (i) PCC foundation for DG set as per manufacturer’s recommendations shall be measured and paid separately under relevant items of Schedule ‘A’ (ii) On successful installation, the DG set shall be subjected to load test as specified below:- Phase-I: No-load test for 01 hour in the presence of engineer-in-Charge. Phase-II: Load test for 12 hours continuously (at 25% of full load for fist one hour 50% of full load for second one hour, 75% of full load for third one hour, 100% load for next 08 hours and 1105 of full load for last one). Resistive type load bank or Water Load, Fuel and testing instruments as required for load testing shall be arranged by the contractor and cost of the same shall deemed to be included in the quoted rate. (iii) Phase-II load test shall be carried out in the presence of testing officer nominated by accepting officer or IEM.
Supply, laying and testing cable XLPEInsulated ,screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with 600mm x 600mm x 6.0 mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including GI Strip of size 32mm x 6mm by means of bolts, nuts and check nuts and washers of galvanised steel (and 50 mm dia GI light grade pipe for protection of GI strip) to the extent of 7.5 metres as earthing lead and connecting to the eqpt, viz transformer, L.T panel etc. including charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No. 3 of SSR - 2009 Part I including chamber made up of PCC 1:2:4 type B1 with M.S angle iron frame, C.I Cover with provision of locking arrangement and 20 mm dia light grade GI Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, Material and labour complete including excavation and earth work in any type of soil strata and testing complete all as specified and directed by Engr-in-Charge.
S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor/indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured /PVC aluminium conductor cable of size16 to 35 Sqmm complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed by Engr-in-Charge.
Returning filling in including, spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and laying GI tube 50 mm light grade as in cable protection pipe including all fittings & taking down / taking out from trench complete all as specified and directed by Engr-in-Charge.
Supplying & laying PCC Cable Cover of size (250x150x40mm) for laying of LT Cables complete all as specified and directed by Engr-in-Charge.
NARINDER KUMAR SONS
AGGARWAL & CO
LM CONSTRUCTIONS
M/s R.N Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .