| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC CONTRACT AWARDED | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹45.1 L
EMD Value
₹90,175
Closing Date
7 Nov 2020, 2:00 pmClosed
MD, NHM
Office of MD,NHM Christian Basti, Ghy-05
Repairing Renovation of 234 nos of SCs to upgrade them as HWC Grp No K 8 Nos in Jorhat District
2020_NHM_19048_17
32050/52/2019-Const/614 dtd 12-10-20
Open Tender
Civil Works
Item Rate
100 days
Jorhat
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
State Health Society
₹90,175
Yes
16 Mar 2021
23 Oct 2020
9 Nov 2020
23 Oct 2020
7 Nov 2020
23 Oct 2020
Amount
REPAIRING AND RENOVATION OF EXISTING PART Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels.
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(a) In cement mortar in proportion 1:4.(1 cement:4 sand)
PLASTERING AND POINTING WORKS 15 mm thick Cement plaster in single coat on brick/concrete walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (b). In cement mortar 1:4
40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). (a) 1.25mm thick sheet (ii) Size 105mm x 60mm (Single rebate)
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core.(35mm Thick)
Providing fitting and fixing 1/3 panelled 2/3 glazed wooden shutters for doors/windows including oxidised iron butt hinges (100mm x75 mm x3.55 mm) with necessay screws including glass panes (other fittings to be measured and paid separately) B) With 1st class local wood (Gamari/Hollock/Bonsum ) (ii) 35 mm thick.
Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels.
Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made fromm extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mmx37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. PVC multicavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filled with PVC panels of approved colour of size 100mmx20mm. Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid seperately) (b)Fixed windows and ventilators ii) 5mm frosted glass
P.C.C WORKS Plain Cement concrete Works with coarse aggregate of size 13 mm to 32mm in foundation of steps, footing of column and plinth beam as directed and specified including curing complete (shuttering where necessary shall be measured and paid separately) In prop. 1 cement:3 Sand :6 Coarse aggregate by volume.
R.C.C WORKS Providing and laying plain/reinforced cement croncrete works in prop 1:2:4:(1 cement :2 coarse sand :4 graded stone aggregate, 20mm down ) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level (ii) Column, Pillars, Post and struts……..
R.C.C WORKS Providing and laying plain/reinforced cement croncrete works in prop 1:2:4:(1 cement :2 coarse sand :4 graded stone aggregate, 20mm down ) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
D.P.C WORKS Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
FORMWORKS Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work. Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Columns, Pillars, Posts & Strut Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.For depth not exceeding 1.0M. Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.Using 25mm thick plank
IRON AND STEEL WORKS Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). b) TMT Bar(I) TATA/ SAIL
VITRIFIED TILES (ON FLOOR ) Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range (sizes 600mmx600mm and above) Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.(A) CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).a) Normal range (Sizes 200 mm x 300mm and above) a) Orient made
Pre-cast cement concrete tiles 20 mm thick with aggregate of sizes up to 6 mm laid in floors, treads of steps and landing with 20 mm thick bed of cement mortar in prop. 1:6 (1cement : 6 coarse sand ) joined with neat cement slurry with pigment to match th
CEILING WORKS Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid. (A) Standard Ceilings of Everest make or equivalent as directed by the department (b). 4 mm thick.
Providing plinth protection with bricks flat laidin cement mortar 1: 4 and finished with 15mmthick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cementmortar in proportion 1:5 with half brick thickside walls and 100mm thick C.C (1:3:6) baseover one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with afloating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refillingthe sides after completion of work etc. asspecified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
BARGE BOARD Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
ROOFING WORKS Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid separately). (b) 0.50 mm thick (ii) 230 mm lapping
Providing galvd iron ridging of TATA SHAKTEE / SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (b) 0.50 mm thick (ii) 230 mm lapping HEXAGONAL WIRE NET ROOF TRUSS
Providing undressed wood work in roof truss, rafter, purlin, tie and the like including hoisting and fixing in position with necessary spikes, nails including M.S straps with bolt and nuts etc.complete with kiricide oiling two coats to all timber members and two coats of anticorrosive paint to M.S straps (M.S flats, angle cleats, and bolt and nuts required for flat and angle cleats wherever used shall be measured and paid separately) (b) With Hollock/ Sundi/ Sam
Providing wood work in frames of false ceiling ,partitions etc. sawn, wrought, framed hoisted and fixed in position with spikes, nails, bolts etc. with 1st class local wood (Gamari/Bonsum/ Sundi)
PAINTING WORKS Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
f) Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing wall with water proofing weather coat smooth anti-fungal exterior painting of Ace brand of Asian Paints and of required shade on old/new wall surface after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying priming coat over new wood based surfaces up to 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (a) With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Painting one coats on old G.C.I sheets with ready mixed anticorrosive paint of approved brand and shade suitable for painting over G.C.I sheets to give an even shade including the cleaning the rust patches with emery paper, dust ,dirt, grease and other foreign matter with water complete.
Painting one coats on old G.C.I sheets with ready mixed anticorrosive paint of approved brand and shade suitable for painting over G.C.I sheets to give an even shade including the cleaning the rust patches with emery paper, dust ,dirt, grease and other foreign matter with water complete.
Extra over item no.13.8.3 for every subsequent coat of paint.
FOR RAMP Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in substructure upto plinth level (in prop. 1:4 )
Earth/Sand filling in plinth in layer not more than 150 mm thick including necessary carriage,watering,ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary (C) With river sand or silt by truck carriage including loading and unloading )
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(a).Brick on flat soling.
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. 35mm thick
Pre-cast cement concrete tiles 20 mm thick with aggregate of sizes up to 6 mm laid in floors, treads of steps and landing with 20 mm thick bed of cement mortar in prop. 1:6 (1cement : 6 coarse sand ) joined with neat cement slurry with pigment to match th (c) Any shade or combination of shades using grey cement. (iv) Pre laminated board
BARBED WIRE FENCING Supplying, fitting and fixing goat proof wire fencing 1200mm high with horizontal wire spacing at 100mm, 100mm, 100mm, 100mm, 100mm, 100mm,150mm, 150mm, 150mm and 150mm from bottom onwards and vertical wires at 130mm apart, first 3 horizontal wires from top barbed wire apart, first 3 horizontal wires from top barbed wire 12 S.W G.x 2 plies x 4 points x 100 mm apart bottom wire 10 S.W.G. fitted with angle iron posts specified in item no.17.7 above including supplying, fitting and fixing with necessary hooks, bolts and staples etc. and painting one coat to all iron posts etc. with anti-corrosive black paint etc. complete as directed and specified(intermediate and straining post should be placed not more than 4000 mm and not less than 3000 mm apart and all posts embedded in C.C. pillars of size 300mm x 300mm x 600mm in prop 1:3:6).
ALUMINIUM FITTINGS Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolt (300mmx16mm)
b) Tower bolt 250mm x 12mm
c)Dooor/window handle 150mm x 12mm
SANITARY WORKS Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) (WHITE Hindware make) (iv) Water closet POPULAR "S (Cat.No.20044) (inclusive of seat cover)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) (White without padestal) (i) Star Basin 550 x 400 (Cat. No.C0450)
Providing fitting & fixing laboratory sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately. (B) Hindware make (White) (ii) Size 450 x 300 x 180 (Cat.No.50001)
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
Supplying fiting and fixing PVC pipes of 6Kgf/cm2 (Supreme/Prince) or ISI approved including joining , fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches. 110mm dia.
75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed faces or trences 110mm dia.
75mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed faces or trences 110mm dia.
75mm dia.
WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe Exposed or in trenches c) 25 mm nominal outer dia pipe
(B) Concealed pipe with cutting chases & making good the walls a) 15 mm nominal outer dia pipe
b) 20 mm nominal outer dia pipe
Providing, fitting and fixing C.P. Grating to the floors complete as directed and specified. (ii) 110mm dia
WATER SUPPLY WORKS Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) 25 mm dia
Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.20 mm dia
15 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquare make Continental /Clarion Standard
Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed. 25 mm dia
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex/ Polycon/Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed. 500 litre capacity (b) Polycon make
EXTERNAL WATER SUPPLY WITH STEEL STAGGING Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling ( return filling ) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. ( Upto a depth of 2m below the existing ground level ) In ordinary soil.
Plain Cement concrete Works with coarse aggregate of size 13 mm to 32mm in foundation of steps, footing of column and plinth beam as directed and specified including curing complete (shuttering where necessary shall be measured and paid separately) Cum In prop. 1 cement:3 Sand :6 Coarse aggregate by volume.
Structural steel work in sigle sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. c) In M.S. angles, channels, Tees etc.
External Water supply HAND PUMP, TUBE WELL, TEST BORING Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Labour for sinking tube well with 40mm (internal) dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long.
Supplying, fitting and fixing lift and force Maya hand pump of approved with all accessories complete as directed by the Department..
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. G.I. Pipe (b) ITC/ NEZONE (medium) (sockets should be welded to the pipes) (iii) 40mm diameter
RCC Ring well (BURIAL PIT) Construction of R.C.C. ring well of 900 mm inside diameter including supplying necessary ring of 75mm thick and 500mm high of prop 1:2:4 reinforced with 6mm dia M.S. rod at 230mm c/c vertically and 5nos of 6 mm dia bar horizontally along with R.C.C. well curb of size 400mm high and 100mm thick at top and 50mm thick at bottom in prop. 1:2:4 reinforced with 5nos of 6mm dia rod at 200mm c/c vertically including sinking of R.C.C. ring to a required depth bailing out water, mud etc. if necessary and fitting and fixing of R.C.C. kerb and ring in proper position with cement mortar of prop. 1:2 including with fitting in sides by sand in layer not more than 150mm and duly compacting the same up to the platform level complete as directed by the department. (a) Up to 1.50m depth .
Supplying fitting, fixing, testing and commissioning of following capacity motor (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) complete with necessary connection as approved, specified and directed by the Department 1 HP single phase 1420 rpm
ELECTRICAL WORKS Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length. Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete Medium point up to 6.00 metre. Length
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 8 way SPN double door
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.40A
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.6 to 32 Amps
Supplying & laying of 6SWG GI. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) with twin twisted flexible cord including connection as approved by the Deptt.)complete Without Lamp
Supplying and fitting of 11/15 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt
upplying including installation of Inverter (Su-Kam/ Microtech/ V-Guard/ Luminous) with Battery and its case as per direction and specified by the Deptt Sine wave Inverter 800 VA/240 V
Non Schduled items Internal wiring for inverter
fitting of S Hook
Supplying and erection PSC pole 8.5 metre long, the pole is to be erection in 1:2:3 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metre complete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
Supplying and erection of L.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x 6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/14 SWG dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and erection of L.T. Pin insulators with G.I. pin complete with blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of L.T. Shackle insulators with shackle strap complete with blots and nuts coach screw etc. as required and as directed by the department.as required
Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department..
Non Scheduled Items supplying fitting & fixing static watt hour meter single phase 220/230 volts 50Hz including supplying & fitting required size of meter box digital meter (richa/Bentec)
Payment to be made to A.S.E.B for load & meter security
Twin Core 10 Sqmm Alluminium Weather proof Wire for service connection
Septic Tank" (For 10 users) CIVIL WORKS Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling ( return filling ) the quantity as necessary after completing of work, breaking clods in return filling, dressing
Plain Cement concrete Works with coarse aggregate of size 13 mm to 32mm in foundation of steps, footing of column and plinth beam as directed and specified including curing complete (shuttering where necessary shall be measured and paid separately) in prop. 1 cement:3 Sand :6 Coarse aggregate by volume.
Providing soling in foundation and under floor at all levels with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials, and if necessary dewatering,
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in substructure upto plinth level ( in prop. 1:4 )
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be paid seperately.
Providing and laying plain/reinforced cement croncrete works in prop 1:2:4:(1 cement :2 coarse sand :4 graded stone aggregate, 20mm down ) including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement.Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. In super-structure from plinth level upto 1st floor level:
Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire.a) SAI/BISCON 10mm dia
c) ISI approved - M.S. Rod 6mm dia
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same .Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .