Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.5 L+₹1.1 L (3.43%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹32.9 L+₹1.5 L (4.71%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹35.2 L+₹3.8 L (12.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹42.4 L
EMD Value
₹84,700
Closing Date
25 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
SPL REP TO BULD NO P56 OF EQPT DIVN PROVN OF CC PITS FOR INST OF WOODEN BALLIS AT OP 5000M AND OP 7000M FOR LOCATION MARKING OF DIST AT 122 PLACES AND PROVN OF 02 NOS INCINERATOR NEAR BLDG NO P230 BLDG NO P82 AT TECH AREA CPE ITARSI UNDER GE BHOPAL
2024_MES_686405_1
8345/E8
Open Tender
Civil Works
Item Rate
183 days
ITARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹84,700
Yes
10 Feb 2025
29 Nov 2024
27 Dec 2024
29 Nov 2024
25 Dec 2024
13 Dec 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Demolition of cement concrete in ground floors and paving (unreinforced) n exc. 15 cm thick, (below or above ground level), complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, over and incl screed bedding 20mm thick in CM 1:6 complete all as specified and directed.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm screed bed in CM 1:4 as backing coat complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 with using 12.50 mm graded stone aggregats as in sub base of flooring, finished even and rough to receive the top layers all complete as specified and as directed.
M&L for Joint less non - skid coloured ceramic tiles 8 to 9 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bedding 15mm thick in cm(1:6) complete all as specified and directed.
Taking down cement plaster from stone/brick walls including raking out joints for keys and scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10 mm thick on other than fair of brick of concrete surface in M 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on brick work or concrete concrete surface in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of wall and applying two coat of white wash complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coat of white wash all as specified and directed .
Demolition of brick work or stone/boulder masonry build in cement mortar including all quoins arches pillars etc. complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on exc 6 m mean radius, old size in CM 1:6 complete all as specified and directed.
All as per item No. 16.00 here-in-before but except Bricks.
M&L for cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in coping and similar work complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, with ridge, gutters, etc, any gauge, and thickness incl Nainital pattern roof covering, fibre glass reinforced translucent corrugated sheeting, fixed with J or L hooks or coach screws complete all as specified and directed.
S & F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
All as per item No. 20.00 here-in-before but except sheets.
M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down/dismantling steel rolling shutter of any size, steel work including door, gate etc. (Area not exceeding 12 Sqm each) complete all as specified and directed.
Supply and fixing 1.25mm thick of laths of gear operated gear operated type with bevel gear box and crank handle steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete all as specified and directed.
Taking down the existing rolling shutters from the existing opening and refixing the same in position after carrying out necessary repairs including oiling, greasing, easing out etc. all as specified and directed by Engr-in-Charge.
Dismantling of wrought iron or mild steel work of any description not other wise provided complete all as specified and as directed
Supply and fix rolled mild steel Fe-410-w (grade E-250) quality A framed work such as grills, gratings, angle for ventilators etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work complete all as specified and as directed.
Supply and fix rolled mild steel Fe 410-W (Gde E- 250) quality A,for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc and similar work complete all as specified and as directed
M&L for preparation of old steel surfaces and applying one coat of synthetic enamel paint over 10 cm width or girth complete all as specified & directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over 10 cm width or girth over and incluidng a coat of red oxide primer etc. complete all as specified & directed.
M & L for preparation of new steel surfaces and applying two coats of aluminium paint of any description over 10 cm width or girth over a coat of red oxide primer complete all as specified & directed.
M & L for preparation of old steel surfaces and applying one coat of aluminium paint paint over 10 cms width or girth etc. complete all as specified & directed.
Demolition of RCC any descripation and any postion not otherwise specifically provided complete all as specified and directed.
M&L for RCC type B0 1:2:4 (12.5mm graded stone aggregate) as in lintel beam, Chajjas etc. complete all as specified & directed.
M & L for RCC (Design mix) M-20 (20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete etc. complete all as specified & directed.
Use & waste for form work rough finished surface of concreate to edge of flat, to sides and RCC shelves in wall complete all as specified & directed.
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) ot less than 0.9mm dia or securing with clips, complete all as specified and directed.
All as per item No 37.00 here-in-before but 6 to 8mm dia bars in stirrups, spacers and binders.
Taking down Chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames n exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Supply and fixing for pressed steel frame for doors with one or more rebates size of frame 105x60 mm including necessary fixing lungs hinges lock strike plate etc complete all as specified and directed.
S&F for factory made, second class hard wood, 35 mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers size of members as specified in SSR Part- I Section 8 Clause 8.24 (a) complete all as speified and directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified & directed.
S&F for sheet glass, ordinary quality, 3 mm thick and glazing with oil putty or wooden beads, in square n exc. 0.5 Sq.m pane, complete all as specified and directed.
S&F for mild steel work as in hold fast, clamps and similar work complete all as specified & directed.
M&L for PCC 1:2:4 type B0 (12.5 mm graded stone aggregate) as in anchoring, hold fast and back filling of pressed steel door frame etc bed plate etc complete all as specified and directed.
M&L for preparation of wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying two coats of synthetic enamel paint over a coats of pink primer complete all as specified and directed.
S&F for 125 mm long mild steel butt hinges, medium weight, cold rolled and fixed complete all as specified & directed.
S&F for 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed.
S&F for 150 mm long aluminium handles, cast type, anodised and fixed complete all as specified & directed.
S&F for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified & directed.
S&F of wire netting as chicken wire mesh of galvanised steel wire 0.71mm dia and size of mesh 25mm for cracks fixed with nails etc complete all as specified and directed.
M&L in repair stainless steel wire cloth 0.36mm nominal dia of wire & average width of aprature 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
Taking down/removing existing roof teatment including backing coat and cleaning of roof slab surfaces including sweeping clean and washing down with water to remove dust and M&L for providing water proofing treatment with polymeric standard water proofing membrane complete all as specified and directed. water proofing work done with following steps:- (a) Applying 15 mm thick plaster in cement mortar (1:3) using water proofing compound to roof and similar work finished the surface even and fair without using extra cement. (b) Applying evenly a tack coat of industrial bitumen 85/25 @1.20 Kg/sqm. (c) Supplying and laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including coping on the surfaces with torch application of membrane with 10cm over laps as required. (d) Applying two coats of aluminium paint @ 0.2 kg/sqm. (e) Conducting ponding test done for 72 hrs for leekage/seepage.
Excavation in post holes not exiting 0.5 cum, getting out returning, filling in and ramming earth and broken hard core/rubble mixed with earth with around the layers not exiding 25 cm each layers watering and removing surplus soil to a distance not exceeding 50 cm making good complete in loose soil complete all as specified and directed.
Use and waste for formwork to edges of concrete flats, treads, breaks in floors, window cill and roof not exceeding 200mm wide and sides of RCC/PCC band in walls (horizontal or slooping and similar work) for flat rough concrete surfaces complete all as specified and directed.
S&F of mild steel pipes of 150mm size of bore, heavy grade with all fittings laid in floors or fixed to walls and ceilings etc complete all as specified and directed.
M&L for applying two coats of Black bituminous paint on surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5m depth for foundation , ext n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out. all as specified and directed in Hard/dense soil complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on exc 6 m mean radius, in CM 1:4 complete all as specified and directed.
M&L for Bricks, sub class 'B' bricks with half brick wall laid flat, in floors bedded and jointed in cement mortar 1:4 complete all as specified and directed.
M&L for 75mm th PCC 1:3:6 type C-2 (using 40 mm graded agg) as in plinth protection with smooth finish without using extra cement complete all as specified and directed.
M&L for hard core of broken stone aggregate of gauge n. exc 63mm under plinth protection complete all as specified and directed.
M&L for flush pointing to brick wall in CM 1:4 complete all as specified and directed.
M&L for key pointing to brick wall in CM 1:3 complete all as specified and directed.
S&F for mild steel plain black sheet 1.25mm thick as in chimeny and similar work, cut to shape and size including necessary welding, revitting, nuts, bols and washers as required at site complete all as specified and directed.
S&F for framed mild steel work of Fe 410 -W (Gde-E- 250) as in feed opening door and lid for feed opening etc cut to shape and size including necessary welding, revitting, nuts, bols and washers as required at site complete all as specified and directed.
M & L for 100mm thick PCC 1:4:8 type D2 as in sub base complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade complete all as specified and directed.
Returning & filling in including ramming, watering and consolidation as required of soil complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunken in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor FRLS cable 1100 volts grade drawn into and including concealed rigid non mettalic PVC conduit medium grade not less than 20 mm ( ISI marked ) with all fitting and fixing accessories including modular sunk in pressed steel chromium plated terminal flush boxes, conceled in wall of make & maching the existing surface ) with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators, metal flush box and white sheet cover of any module as required at site etc and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :-
One light point/fan point controlled by one switch
One socket outlet 5 Amps controlled by one switch on the same board.
One socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 76.00 here-in-before but with 2.5 sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 sq mm PVC insulated multisranded copper conductor cable as continuous earth wire complete all as specified and directed.
Material and labour in repairs for sub main wiring with two single core 4.0 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 25 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in conceled in wall of make & maching the existing surface make & maching the existing surface and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable submain of any size all as specified and directed. Note:- Two runs of 4.0 sqmm copper conductor cable, one run of 4 sqmm copper conductor and one run of PVC conduit will be measured as one unit.
S & F ceiling rose surface bakelight two to three terminal complete all as specified and directed.
S&F modular switch 1 way 6A, 240 volts 1 module complete with cover and frame complete all as specified and directed.
S&F modular switch 1 way 16A, 240 volts 1 module complete with cover and frame complete all as specified and directed.
S&F modular socket, 6A, 2/3 pin combined 2 module complete with cover and frame complete all as specified and directed.
S&F modular socket 6A/16A, 2/3 pin combined 2 module with cover and frame complete all as specified and directed.
S & F modular fan step regulator, 120W, 240 volts 2 module complete all as specified and directed.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete with cover and frame all as specified and directed.
Supply and fixing LED lights fitting 1x 40W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix for sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 8 way 200 Amps rated bus bar to be fixed with wall all accessories complete all as specified and as directed.
S & F MCB single pole 240 volts 6 to 32 Amps complete all as specified and directed.
S & F MCB double pole 240 volts 16 to 40 Amps complete all as specified and directed.
M&L for earthing complete with glavanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground leves) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nut , bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber , reassed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Pt-I 1991 print and as directed. Note:- (i) Item of earthing includes cost of excavation, removing, PCC Chamber, 15mm bore medium grade GI protection Pipe (7.5 Meters long) for earth lead any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25% (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of Engr-in Charge.
Supply and fixing LED Bldg/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and GI pipe 40 mm dia, light grade for mounting bracket bent to shape 1.50 RM and fixing arrangement with two Nos of MS clamps set, nut bolts, washers of suitable size complete all as direcetd and as specified.
Materials & labour in replacement of 1100 volts grade heavy duty XLPE cable of size 50 Sqmm 3.5 core, passing through GI pipe with aluminium conductor stranded polyethylene insulated, conductor served with and including sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete including taking down existing unserviceable UG cable of any type and size all as specified and directed.
M & L sand filling in trenches for cable cushioning with clean, dry and unwashed sand free from sharp particles including gently punning around cable complete all as specified and directed.
Supplying and laying Class LV, type I, flat, size 250mm x 150mm x 40mmfor cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
M & L of GI pipe, light grade, 80 mm dia bore with all fittings and fixed complete to wall, to pole or laid in trenches and road crossing complete including taking down unserviceable GI pipe of any size all as directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 108093.00
pyarelal galar (BID ID -3194597)
TANUJ CONST. CO. (BID ID -3197790)
M/S HARSH VIKAS GALAR ENGINEERING (BID ID -3192589)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .