| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-Finance LANE NO 05 HNO 56 SHIV VIHAR TALAB TILLO JAMMU | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹1.2 L+₹2,707.72 (2.41%)Rejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.2 L+₹8,123.16 (7.23%)Rejected-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L3 | Rejected-Finance Being L3 |
Tender Value
₹1.4 L
EMD Value
₹2,708
Closing Date
27 Feb 2026, 2:00 pmClosed
Executive Engineer
Executive Engineer PWD R and B Gandhi Nagar I/c UWD
Providing new power points computer points in Autoclave room including new wiring in Department of BIO technology at New University Campus
2026_UDJK_303739_1
enit 145 dated 11-02-2026
Open Tender
Electrical Works
Percentage
30 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
Yes
Executive Engineer PWD R and B Gandhi Nagar I/c UW
₹2,708
5 Mar 2026
18 Feb 2026
2 Mar 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
Part-A (Sanctioned Schedule items)Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/HPL/KEI/polycab/) Equivalent make of required specification to be approved by the Engineer In charge) i.2x1.5 Sq mm +1x1.5 Sq mm
ii.2x2.5 Sq mm + 1x2.5 Sq mm
ii. 2x6 +1x6 Sq mm
iv.4x10 Sq mm + 2x6 Sq mm
Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply and Fixing following ratings, four pole, 415 volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. 100 Amp ratings (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep
200mm x 125mm x 60mm deep
Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Great White/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/ Anchor/Great White/ Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing following ways horizontal type three pole , and Neutral, sheet steel MCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.8 way(4+18), Double door Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge
Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Wire Make ISI Marked Havells/Anchor/KEI/Polycab ) (Conduit Make - ISI Marked Anchor/High Power /AKG Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘B’
Supplying and fixing following ways horizontal type MCB Distribution Board 230V on surface/in recess complete interconnections including powder painted earthing etc. as required (But without MCB/SPN.) i.4 way, DD For A.C Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge
Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient .(Make: Havells /Anchor /Crompton/USHA Equivalent make of required specification to be approved by the Engineer In charge)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_986441.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .