Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.3 L+₹4.4 L (15.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.4 L+₹5.6 L (19.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.5 L+₹5.7 L (19.7%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹63,907
Closing Date
11 Sept 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Thanakalan
Working estimate for drilling, lowering of assembly and development of T/well 150 mtrs deep T/well at Takka and T/well 140 mtrs deep T/well at Lower Basal (Nr. Govt. Hight School)
2023_HPIPH_77985_1
UNA-UNA03-733
Open Tender
Civil Works
Item Rate
60 days
Thanakalan
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
₹63,907
5 Oct 2023
25 Aug 2023
11 Sept 2023
25 Aug 2023
11 Sept 2023
25 Aug 2023
25 Aug 2023 - 11 Sept 2023
Amount
Transportation of Rig along with allied accessories etc. complete including errection and levelling at site, through all kinds of roads, approaches fields errection and levelling at site, through all kinds of roads, approaches fields etc. in all leads and lifts completed in all respects as per the directions of Engineer - in-Charge.
Drilling of bore as per specifaction laid down in IS2800-1991 (part-I) with upto-date amnedments,if any,with Direct Rotary Rig drilling starting with 650-600 mm dia M.S pipe reduced to 450-400 mm dia M.S pipe conforming to IS 4270-2001 with up-to-date amendements,if any, in all kind of soils,boulders,rocks,collapsible strata,sturated soils,artesian conditions including the cost of all consumable, stores water,fuel, lubricants and other accessories etc. complete in all respectsd as per the directions of the Engineer -in -Charge.
Drilling and lowering of with Rotary/ Precussion Rig conforming to IS 4270-2001 with up-to-date amendments,if any, of suitable sizes as mentioned above,from 0-30 mtrs below ground level within all leads and lifts.
Drilling and lowering of with Rotary/ Precussion Rig conforming to IS 4270-2001 with up-to-date amendments,if any, of suitable sizes as mentioned above,from 30-60 mtrs below ground level within all leads and lifts.
Drilling and lowering of with Rotary/ Precussion Rig conforming to IS 4270-2001 with up-to-date amendments,if any, of suitable sizes as mentioned above,from 60-90 mtrs below ground level within all leads and lifts.
Drilling and lowering of with Rotary/ Precussion Rig conforming to IS 4270-2001 with up-to-date amendments,if any, of suitable sizes as mentioned above,from 90-150 mtrs below ground level within all leads and lifts.
Collection ,preservaion and display of suitable size sample box with top lid and locking arrangement till handing over of the tube well to the department complete in all respects as per direction of the Engineer -in-Charge.
Supplying & Lowering of IS marked Electric Resistance Welded Screwed End Socketed M.S.pipe 300 mm dia nominal size housing, 8 mm thick having out side dia mtrs.323.9 mm (Screwed End Socketted), conforming to I.S 4270-2001 with up-todate amendments, if any ,about 4 mtrs to 7 mtrs in length, welded without any circumferential joints,into bore hole in vertical position including cost of all scaffolding derricks,poles,clamps embedded in foundation etc. including cost of all cutting,threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the directions of the Engineer -in-Charge.
Supplying & Lowering of IS marked Electric Resistance Welded Screwed End Socketed M.S.slotted pipe 300 mm dia (1020 slots per mtrs) nominal size housing, 8 mm thick having out side dia mtrs.323.9 mm (Screwed End Socketted), conforming to I.S 4270-2001 with up-todate amendments, if any ,about 4 mtrs to 7 mtrs in length, welded without any circumferential joints,into bore hole in vertical position including cost of all scaffolding derricks,poles,clamps embedded in foundation etc. including cost of all cutting,threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the directions of the Engineer -in-Charge.
Providing and fixing M.S taper/reducer as per lengths approved by Engineer -in-Charge, the material of M.S taper/reducer shall be equivalent to parent pipe material and shall conform to chemical composition as per clasue 5.2 and mechanical properties as per clasue 6.1and table 1 of IS 4270-2001 with upto date amendments,if any, complete in all respect as per directions of the Engineer -in -Charge.
Supplying & Lowering of IS marked Electric Resistance Welded Screwed End Socketed M.S.pipe 200 mm dia nominal size housing, 6.4 mm thick having out side dia mtrs. 219.10 mm (Screwed End Socketted), conforming to I.S 4270-2001 with up-todate amendments, if any ,about 4 mtrs to 7 mtrs in length, welded without any circumferential joints,into bore hole in vertical position including cost of all scaffolding derricks,poles,clamps embedded in foundation etc. including cost of all cutting,threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the directions of the Engineer -in-Charge.
Supplying & Lowering of IS marked Electric Resistance Welded Screwed End Socketed M.S.slotted pipe 200 mm dia (942 slots per mtrs) nominal size housing, 6.4 mm thick having out side dia mtrs. 219.10 mm (Screwed End Socketted), conforming to I.S 4270-2001 with up-todate amendments, if any ,about 4 mtrs to 7 mtrs in length, welded without any circumferential joints,into bore hole in vertical position including cost of all scaffolding derricks,poles,clamps embedded in foundation etc. including cost of all cutting,threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the directions of the Engineer -in-Charge.
Pdg. and fixing M.S cetralized guides at suitable spacing for each tube well as per IS 226-1991 with upto-date amendments,if any, within all leads and lifts ,1x4Nos. completed in all respects in all respects as per the directions of the Engineer -in-Charge.
Supplying ,lowering and fixing in position IS marked mild steel bail plug of 200 mm/300 mm diameters with "U" hooks as per IS 2800-1991 with up to date amendements ,if any, within all leads and lifts, complete in all respects per directions of the Engineer -in- Charge.
Pdg. and fixing in position threaded iron cap with locking arrangements of approved design to prevent foreign matter from getting into bore hole,as required, within all leads and lifts, complete in all respects as per directions of the Engineer -in- Charge.
Supplying and packing of gravel, consisting of hard quartz or other suitable material with an average specific gravity of not less than 2.5,not containing more than 2% by weight of thin flat of elangated pieces, shall be of sub rounded to rounded grains with minimum angular features of size 2-3.35 mm , shall be free from impurities such as shafe,shale,mica,felspar,clay,sand,dirt loam,baematte and organic material as pe IS 4097-1967 with upto date amendments, if any, around intake of tubewell with minium thickness of shroud around screen generally 100 mm to the entire depth of the bore as per 2800(Part-I ) 1991 with upto date amendments, if any, with in all leads and lifts complete in all respects as per direction of the Engineer -in- Charge.
Development of tubewell by back washing method,with air compressor of minimum 750 CFM capacity, pumping pipe of 200 mm size and air line of minimum 65 mm size or with other suitable method,till the well is thoroughly developed as per clause 4.2 of IS 11189 -1985, with upto date anebdnebts,if any, complete in all respects as per direction of the Engnieer -in- Charge.
Development of tubewell by continous over pumping method,with VT pump/ submersible pumps of suitable capacity not less than double the discharge established by the compressor method/ design discharge, untill the well is sand free as per IS-11189-1985 up -to- date amendments, if any, complete in all respects as per directions of the Engineer -in- Charge .The draw down and discharge to be established by running the VT/ Submersible pump continuosuly for 8 hours in the presence of officer not less than the rank of Assistant Engineer.
Testing the verticality of the tubewell as per clause 4.3 of IS 2800 (Part-II) 1979 with upto date amendments, if any, using plumb or plunger 6 mm smaller in dia within the inside diameter of the well casing.The results of the verticality test shall be recorded on proforma shown in Appendix A of IS 2800 (Part-II) 1979 with up-to-date amendments, if any, as appended with the tender documents and handed over complete in all respect as the directions of the Engineer -in- Charge.
Dismentalling of Rig or other allied accesssories after completion of job within all leads and lifts, complete in all respects as per the directions of the Engineer -in- Charge.
Handing over of the tubewell in complete shape as per appendex "B" of clause 7 of IS 2800 (Part-II) -1979 with upto date amendmentes if any, as appended with the tender documents, in laminated form , in triplicate, complete in all respect as per the directions of the Engineer-in-Charge.
M/s POPULAR DRILLERS
SWAMI RAMJI BORE WELLS
Akarshan Jaswal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .